# Veolia Environmental Services — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 07-0074
- **title:** Veolia Environmental Services — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2007-05-15
- **effective on:** Not available
- **summary:** 07-0074 response to Veolia Environmental Services concerning 172.504.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-07-0074.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-07-0074.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-07-0074
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070074.pdf
**body:**

<<<PAGE 1>>>

.S. Departme
f Transportatio
Washington, D.C. 20590
400 Seventh Street, S.W.
Pipeline and
Administration
Hazardous Materials Safety
MAY 15 2007
Ms. Jennifer Eberle
Ref. No. 07-0074
Veolia Environmental Services
Manager, Transportation Compliance
Flanders, NJ 07836
One Eden Lane
Dear Ms. Eberle:
This responds to your April 10, 2007 letter requesting clarification on the use of the
49 CFR Parts 171-180). Specifically, you ask for confirmation that the DANGEROUS
DANGEROUS placard under §172.504(b) of the Hazardous Material Regulations (HMR;
placard is not required in your situation.
gross weight of three Table 2 materials in non-bulk packages as follows: Class 8 and Class
According to your letter, you have a truckload shipment of 3,300 pounds total aggregate
3 materials (500 pounds each) and Division 5.1 material (2,300 pounds) loaded at one
loading facility.
Section 172.504(b) authorizes the use of the DANGEROUS placard instead of the separate
placards specified for the three hazardous materials in Table 2 for shipments of two or more
categories of Table 2 materials in non-bulk packages that require different placards. Thus,
the DANGEROUS placard is authorized for your mixed truckload shipment. However,
when 1,000 kg (2,205 pounds) aggregate gross weight of more than one category of
material is loaded at one loading facility, the placard specified in Table 2 for that category
must be applied. The DANGEROUS placard is already authorized for use on the mixed
truckload shipment. but, since the aggregate gross weight of the Division 5.1 material
the 2.300 pounds of Division 5.1 material that was loaded at one loading facility.
exceeds the 2,205 pound threshold, the OXIDIZER placard is now also required to cover
truckload shipment to indicate the presence of both the Class 8 and Class 3 materials, as
Therefore, both the DANGEROUS and OXIDIZER placards should be used for this mixed
well as the Division 5.1 materials.
I hope this answers your inquiry.
Office of Hazardous Materials Standards
172.504(b)
070074

<<<PAGE 2>>>

Boothe
@ VEOLIA
5172.504(6)
April 10, 2007
17-0074
Office of Hazardous Materials Standards
Mr. Edward T. Mazzullo, Director
USDOT/PHMSA (PHH-10)
400 7th Street, SW
Washington D.C. 20590-0001
Dear Mr. Mazzullo,
Please accept this letter as a request for a formal interpretation from your office. Veolia
§172.504(b).
wishes to receive clarification related to the DANGEROUS placard exception found in
It is our interpretation that a truckload shipment of non-bulk packages containing the
flaring aggregate gross weights would be required to display only the OXIDIZER (5.1)
Class 8 = 500 pounds
Class 3 = 500 pounds
Class 5.1 = 2300 pounds
Is it correct to no longer consider the weight of a Table 2 material for which a specific
determining the appliedity or the DANGEROUS prass weight of Table 2 materials wher
TABLE 2 MATERIAL
REQUIRED PLACARD
Class 5.1 = 2300 pounds
(>2,205 Ibs. loaded at one loading facility)
OXIDIZER 5.1
Class 3 =
Class 8 =
500 pounds
Total =
1,000 pounds
500 pounds
(Total aggregate weight of Table 2 materials is < 1,001 lbs.)
NONE
Your written response to this question is greatly appreciated. If you require any further
information regarding this letter please contact me at 973-448-4209 o
iennifer.eberle@veoliaes.com.
Thank you,
Jennifer Eberle
Manager, Transportation Compliance
the pore wore.c
for 1 07936
- **truncated:** false