# 4th ID-Fort Carson G3/IMT — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 07-0171
- **title:** 4th ID-Fort Carson G3/IMT — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2007-10-16
- **effective on:** Not available
- **summary:** 07-0171 response to 4th ID-Fort Carson G3/IMT concerning 172.504.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-07-0171.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-07-0171.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-07-0171
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070171.pdf
**body:**

<<<PAGE 1>>>

of Transportation
U.S. Department
1200 New Jersey Avenue, SE
Washington, D.C. 20590
Armans herdous
OCT
16 2007
4*h ID-Fort Carson
Mr. Len Hammond
Ref. No. 07-0171
G3/IMT
1675 Long Street
Fort Carson, CO 80913-4138
Bldg. 1117, Room 207
Dear Mr. Hammond:
requirements in the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180).
This responds to your August 31, 2007 letter requesting clarification of the placarding
Specifically, you ask for clarification on the use of the DANGEROUS placard under
§172.504(b) for your scenarios. Your questions are paraphrased and answered as follows:
Q1: A transport vehicle or freight container is loaded with 1,200 kg of Class 3 flammable
liquids; 200 kg Division 6.1 poison material (not an inhalation hazard); and 300 kg Class &
corrosive material. There are no subsidiary hazard classes. May we apply the Class 3
FLAMMABLE LIQUID placard for Item 1 and the DANGEROUS placard for Items 2 and
Al: Yes. Placards are required because the aggregate gross weight (1,700 kg) of the Class 3,
§172.504(b), the DANGEROUS placard may be substituted for the POISON AND
Division 6.1, and Class 8 hazardous materials exceeds 454 kg (1,001 Ib). As provided in
CORROSIVE placards. The FLAMMABLE LIQUID placard must be used for the Class 3
material since it exceeds 1,000 kg (2,205 Ib) loaded at one facility.
Q2: A transport vehicle or freight container is loaded with 500 kg Division 6.1 poison
material. May we apply only the DANGEROUS placard?
material (not an inhalation hazard); 200 kg Class 3 flammable liquid; and 100 kg Class 8
A2: Yes. The DANGEROUS placard may be used to cover all three Table 2 hazardous
materials.
Q3: A transport vehicle or freight container is loaded with 50 kg Division 6.1 poison
orrosive material. Are placards required'
naterial (not an inhalation hazard); 200 kg Class 3 flammable liquid; and 100 kg Class
17250466)
070171

<<<PAGE 2>>>

(1,001 lb), no placards are required.
A3: No. Since the aggregate gross weight of all three Table 2 materials is less than 454 kg
Q4: A transport vehicle or freight container is loaded with 1,200 (exceeds 2,205 lb) Class 3
Class 3 FLAMMABLE LIQUID the only placard required?
flammable liquid; and 200 kg Division 6.1 poison material (not an inhalation hazard). Is the
A4: No. The FLAMMABLE LIQUID placard is required because 1,000 kg of Class 3
material has been loaded at one facility. However, because the entire aggregate gross weight
lacard or POISON placard must be used for the Division 6.1 material
of hazardous materials on the transport vehicle exceeds 454 kg, either the DANGEROUS
I hope this answers your inquiry.
Sincerely
Chief, Standards Development
Office of Hazardous Materials Standards
2

<<<PAGE 3>>>

Boothe
5172.504(6)
•
MEMORANDUM
Placarding
DATE:
31 AUGUST 2007
07-0172
FROM:
LEN HAMMOND
To:
SHANE KELLEY
GLENN FOSTER
OFFICE OF HAZARDOUS MATERIALS SAFETY, PHH-70
CANDACE SIMON
PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION
400 7TH STREET, S.W. ROOM 8421
U.S. DEPARTMENT OF TRANSPORTATION
WASHINGTON, D.C. 20590-0001
SUBJ:
REQUEST FOR CLARIFICATION ON PLACARDING EXCEPTIONS
I am writing to request clarification and a letter of interpretation of the exceptions
for placarding in accordance with 49 CFR §172.504.
§172.504(a) states that "...each freight container, unit load device, transport vehicle
r rail containing any quantity of a hazardous material must be placarded on eac
ide and each end with the type of placards specified in Tables 1 and 2 of thi
section." As this is the basic rule and can only be deviated from with those
exceptions as listed in subsequent exceptions, it is understood that only those items
meeting one or more of the exceptions listed may be exempted from mandatory
placarding.
Those exceptions include:
"Dangerous" placarding for those items in Table 2 for which a placard is required
§172.504(b) Dangerous Placard. This exception provides for a summarizing
[i.e. does not meet the exception of §172.504(c)]. However as I read this section, this
exception does not apply to those items with an aggregate gross weight of more than
1000 kg.
I would like to offer several scenarios for your clarification in the application of the
Dangerous Placard exception.
Scenario # 1:
A transport vehicle/container/unit load device is loaded with the aggregate gross
weights of the following Hazard Classes.
Item 1: Class 3, Flammable liquids; 1,200 kg
Item 2: Class 6.1, Toxic material (not an inhalation hazard), 200 kg
Item 3: Class 8, Corrosive liquids, 300 kg

<<<PAGE 4>>>

All items are in Table 2 and are qualified for the Dangerous Placard Exception
Item 1 is pretty straight forward as it is greater than 1,000 kg and does not meet the
exception as it is addressed in §172.504(b) under the rule for items greater than 100
kg and must be placarded for.
Items 2 & 3 do not meet the greater than 1,000 kg and are subject to the Dangerous
Placard exception.
Therefore in Scenario # 1 the two placards which are to be applied are the
Flammable Liquid, Class 3 placard for Item 1 and the Dangerous Placard for Items
2 & 3. (Item 1 is not to be considered in the computation of aggregate gross weight
for applying this exception since is greater than 1,000 kg and has already been
placarded for).
Scenario # 2
Item 1: Class 6.1, Toxic material (not an inhalation hazard); 500 kg
Item 2: Class 3, Flammable liquid; 200 kg
Item 3: Class 8, Corrosive solids, 100 kg
All items are Table 2 items but since none are greater than 1,000 kg, they are all
three items is greater than 454 kg therefore the Dangerous Placard can be used to
eligible for the Dangerous Placard exception. The total aggregate gross weight of all
summarize all three items.
Placard required for Scenario #2 is only the Dangerous Placard for all three items.
Scenario # 3
Item 1: Class 6.1, Toxic material (not an inhalation hazard); 50 kg
Item 3: Class 8, Corrosive solids, 100 kg
Item 2: Class 3, Flammable liquid; 200 kg
All items are Table 2 items but since none are greater than 1,000 kg, they are all
eligible for the Dangerous Placard exception. The total aggregate gross weight of all
three items is less than 454 kg therefore no placard is required under §172.504(c)
which states "... except for bulk packagings and subject to §172.505 (subsidiary
hazards requiring placarding), when hazardous materials covered by Table 2 of this
section are transported by highway or rail, placards are not required..." on
transport vehicles/containers/rail cars which contains less than 454 kg aggregate
gross weight of Table 2 hazardous materials.
Placards Required: None

<<<PAGE 5>>>

Scenario # 4
Item 1: Class 3, Flammable liquids; 1,200 kg
Item 2: Class 6.1, Toxic material (not an inhalation hazard), 200 kg
Item 1 is pretty straight forward as it is greater than 1000 kg and does not meet the
exception as it is addressed in §172.504(b) under the rule for items greater than
1,000 kg and must be placarded for.
Item 2 does not meet the greater than 1,000 kg and may subject to the Dangerous
exception of §172.504(c) and does not have to be placarded for.
Placard exception. However since the item is less than 454 kg it falls under the
Placards Required: Flammable Liquid 3 only.
The reason I ask for this clarification is that there are continuous questions as to
for the Dangerous Placard exception. I think that only those Table 2 items which are
whether a Table 2 item greater than 1,000 kg is to be considered in the computation
less than 1,000 kg are to be considered based on the statement in §172.504(b)
"However, when 1,000 kg aggregate gross weight or more of one category of
device, transport vehicle, or tail care, the placard specified in Table 2 of paragraph
material is loaded therein at one loading facility on a freight container, unit load
(e) of this section for that category must be applied." This is as demonstrated in
Scenario # 1.
I think the misunderstanding occurs because of he wording of §172.504(b) is often
misinterpreted to require the inclusion of the aggregate gross weights of all Table 2
items, even those already placarded for under the greater than 1,000 kg rule when
computing the aggregate gross weight for the Dangerous exception. As I read this
section, it seems to exclude those Table 2 items already placarded for under the
greater than 1,000 kg rule. Maybe the more correct statement would be to define the
Dangerous Placard rule to those items in Table 2 not already placarded for under
the greater than 1,000 kg rule. This question is most often raised in response to a
scenario such as in # 4 where the gross weight of the one Table 2 item greater than
1,000 kg is included in the Dangerous Placard exception computation. This would
result in that item being placarded for twice, with its own specific placard and again
under the summarization of hazards eligible for the Dangerous Placard rule.

<<<PAGE 6>>>

:
Could you please review these scenarios and provide a clarification of the
That your no lethe koading ale? pervence rised thie a ra consensu in hopes
Thank you for your assistance in insuring that all instruction is based on the same
application of rule.
Len Hammond
LEN HAMMOND
4'* ID - FORT CARSON
G3/IMT ATTN: LEN HAMMOND
1675 LONG STREET
FORT CARSON, CO 80913-4138
BLDG. 1117, RoOM 207
len.hammond@us.army.mil
- **truncated:** false
- **body characters:** 9312
