# E.I. DuPont de Nemours & Co. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 07-0204
- **title:** E.I. DuPont de Nemours & Co. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2008-01-08
- **effective on:** Not available
- **summary:** 07-0204 response to E.I. DuPont de Nemours & Co. concerning 178.345, 178.35.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-07-0204.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-07-0204.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-07-0204
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070204.pdf
**body:**

<<<PAGE 1>>>

ois. ansporation
1200 New Jersey Avenue, SE
Washington, D.C. 20590
Pipeline and Hazardous
Administration
Materials Safety
JAN O 8 2008
Mr. Kevin M. Greene
Ref. No.: 07-0204
Hazardous Materials Distribution Consultant
2650 Highway 43 Nort
E.I. DuPont de Nemours & Co
Axis, Alabama 36505
Dear Mr. Greene:
This is in response to your request for a clarification of the packaging notification
requirements in Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180).
Specifically, you ask if the packaging notification requirements in § 178.2(c)(1)(i) apply to
cylinders.
The answer is no. Section 178.2(c)(1)(i) requires written notification to each person to whom
a packaging is transferred of all Part 178 requirements not met at the time of transfer. A
cylinder manufactured under Part 178, Subpart C must be in full conformance with all
specification requirements at the time of transfer. The cylinder manufacturer certifies that
these requirements have been met by marking the applicable DOT specification marking on
the cylinder, eg. DOT-3A, DOT-4BW. Additionally, the cylinder inspector is responsible for
ensuring each cylinder made is in full conformance with all specification requirements. See
§ 178.35 (c) of the HMR.
In addition, you refer to a December 1, 2005 interpretation letter (Ref. No.: 05-0209) from
this office in which we specify that paragraph (c) should include a reference to § 178.338-19
and that current reference to § 178.345-10 should be replaced with § 178.345-15. You ask
when we plan to implement these corrections. We are currently considering revisions to the
cargo tank specifications and plan to include these corrections in that rulemaking.
I hope this information is helpful. If you have further questions, please do not hesitate to
contact this office.
Sincerely,
Hattie L. Mitchell
Chief, Regulatory Review and Reinvention
Office of Hazardous Materials, Standards

<<<PAGE 2>>>

oct. 18. 2 0 0 7 1 0 : 5 7 P M d u p o n t 544eyCh -+e '$17 3.2.
N o , 0848 P q 1
Axis, Alabama 36505
DuPont Global Logistics
October 18,2007
Mr. Edward T. Mazzullo
Director, Ofice of Hazardous Materials Standards
U.S. DOT/PHMSA (PHH-I 0)
1200 New Jersey Avenue, SE East Bldg., 2nd Floor
Washington, DC 20590-0001
Subject: Applicability of the notification requirements in 178.2 to cylinders.
Dear Mr. Mazzullo:
On December 1,2005, PHMSA issues a letter of clarification (Reference No.:05-0209) to confirm the
notification requirements in 178,2 are not applicable to portable tanks, cargo tanks and tank cars. However,
the letter did not tnention if the notification requirements in 178.2 are applicable to cylinders.
The notification requirement in 178.2 (c)(l)(i) calls for notification if there is a requirement in this part
(i.e., Part 178) that is not met at the time of transfer. To the best of my knowledge, there is no sucb
requirement in part 178 for cylinders. With that said, is the notification requirement in 178.2 of the
Hazardous Materials Regulations (HMR; 49 CFR P a . 17 1-1 80) applicable to cylinders?
Additionally, PHMSA co~nmunicated in its letter that the current reference to 178.345. I0 in paragraph (c)
is in error and should read 178.345-15. Also, the reference for MC-338 cargo tank certification in 178.338-
19 is missing. PIease advise when PHMSA expects to correct the aforementioned errors in the HMR?
I hope this information is helpful. Please contact me if you require additional assistance.
/a* Kevin M, Greene
Hazardous Materials Distribution Consultant
DuPont Global Logistics
12650 Highway 43 North
Axis, Alabama 36505
Phone: (25 1) 679.5330
Fax: (302) 355.2888
Kevin,in.greene@usa.dupont .corn
- **truncated:** false