# Department of the Army, USAMC LOGSA Packaging Storage and Containerization Center — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 08-0184
- **title:** Department of the Army, USAMC LOGSA Packaging Storage and Containerization Center — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2008-08-18
- **effective on:** Not available
- **summary:** 08-0184 response to Department of the Army, USAMC LOGSA Packaging Storage and Containerization Center concerning 178.602.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-08-0184.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-08-0184.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-08-0184
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2008/080184.pdf
**body:**

<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
AUG 1 8 2P38
1200 New Jersey Ave. S E
Wash~nqton DC 20590
Ms. Charlotte A Lent
Chief, USAMC LOGSA Packaging
Storage and Containerization Center
11 Hap Boulevard
Tobyhanna, PA 18466-5097
Ref. No.: 08-0 1 84
Dear Ms. Lent
This is in response to your July 10,2008 letter regarding non-bulk performance-oriented
package testing under the Hazardous Materials Regulations (HMR; 49 CFR Parts 17 1 - 180).
Specifically, you ask if the HMR restrict test substances for non-bulk packages designed to
contain a liquid hazardous material to liquids having the same or higher)specific gravity than
water and prohibit the substitution of solid materials as a replacement te:st product for liquids.
According to 5 178.602(c), it is permissible to use additives, such as bags of lead shot, to
achieve the requisite total package mass so long as they are placed so that the test results are
not affected. You suggest that bags of lead shot cannot be placed in a way that will not affect
drop test results because load distribution and shock absorption are affedFed and the physical
properties of bags lead shot and other solids are materially different thanla liquid.
If a packaging passes the drop test when tested with bags of lead shot an$ liquid, but would
fail if tested with water or a liquid substance with the same properties as the material to be
transported, the results of the test have been affected. Thus, bags of lead shot are not a
suitable additive.
You may petition for a rule change if you believe that a modification shohld be considered.
Procedures for submitting a petition for rulemaking are in 5 106.95.
I hope this answers your inquiry.
Sincerely,
Acting Chief, Standards Development
Office of Hazardous Materials Standards

<<<PAGE 2>>>

DEPARTMENT OF THE ARMY
W A M t L W S T l t S SUPPORT ACTIVITY
REDSTONE ARSENAL. AL -91-7466
REPLY TO
ATTENTION OF
July 10,2008
Logistics Testing and Applications Division
Mr. Edward T. Mazzulo
Director, Office of Standards
US Department of Transportation
Pipeline and Hazardous Materials Safety Administration
East Building, 2nd Floor, PHH-10
1200 New Jersey Avenue SE
Washington, DC 20590
Dear Mr. Mazzulo:
This letter of inquiry for interpretation is written on behalf of the US Army Materiel
Command Logistics Support Activity Packaging, Storage, and Containerization Center
(USAMC LOGS A PSCC), Tobyhanna, Pennsylvania. The USAMC LOFSA PSCC Packaging
Applications Testing Facility is a packaging test facility for the U.S. Depfutment of Defense
(DoD) where military and commercial packaging testing, including, hazardous materials
packaging UN certification testing, has been performed to military, industry, commercial, and
item or material test methods for 60 years.
This letter is being written for a clarification/interpretation of the requirements of the
Hazardous Materials Regulations (HMR) stated below. It is asked that an interpretation be
provided that restricts test substances for liquid lading to only liquids having the same or
higher Specific Gravity as water (Se1.0), and that solids not be permitted as a
replacement test product for liquids.
§I 78.6020)
"For the drop and stacking test, inner and single-unit receptacles must be filled to not less
than 95% of maximum capacity in the case of solids and not less than 98v of maximum in the
case of liquids. The material to be transported in the packagings may be replaced by a non-
hazardous material, except for chemical compatibility testing or where this would invalidate
the results of the tests. "
$1 78.602(c)
''lfthe material to be transported is replaced for test purposes by a non-hazardous material,
the material used must be of the same or higher specific gravity as the material to be carried,
and its other physical properties (grain, size, viscosity) which might influence the results of the
required tests must correspond as closely as possible to those of the hazardous material to be
transported. Water may also be used for the liquid drop test under the conditions specified in
$1 78.603te) of this subpart. It ispennissible to use additives, such as bags of lead shot, to

<<<PAGE 3>>>

achieve the requisite totalpaclcage mass, so long as they are placed so that the test results are
not aflected. "
This facility routinely uses either water or antifreeze and water solutions for all packaging
testing containing liquids. However, it is common practice in private industry to use lead shot
andlor other solids in place of, or along with, liquids for testing. In the aforementioned
paragraphs of the HMR it is permissible to use bags of lead shot, to achieve the requisite total
package mass, so long as they are placed so that the test results are not aflected. However,
from this facility's 60 years of experience in packaging testing for DoD, it can be stated that--
Bags of lead shot cannot be placed in such a way so as to not affect drop test results. The
load distribution andlor center of gravity are different than when only liquid is used, and
Bags of lead shot cannot be placed in such a way so as to not affect drop test results,
inasmuch as the bags of lead shot (other loose materials) absorb shock before the inner
packaging sees the shock, and
Lead shot or other solids, such as steel bolts, do not have the samephysicalproperties as
liquids and should not be used as a replacement test lading for liquids. A solid is not a
liquid, and does not behave as such.
When using water or other liquids having a Specific Gravity 2 1 .O, the drop heights and
stacking top load already incorporate the Specific Gravity of the intended lading in the
calculations for the drop and stack test parameters per the applicable paragraphs in the HMR.
Point of contact for this matter is Ms. Charlotte A. Lent, (570) 895-7160, fax (570) 895-7823,
or e-mail charlotte.lent@,us.armv.mil. All correspondence responding to this memorandum
should be sent to Chief, USAMC LOGSA Packaging, Storage, and Containerization Center
(AMXLS-ATIMs. Charlotte A. Lent), 1 1 Hap Arnold Boulevard, Tobyhanna, PA 18466-5097.
Sincerely,
' JAMES R. BRYANT
Chief, Logistics and
Engineering Center