# TRG Inc. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 09-0114
- **title:** TRG Inc. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2009-05-19
- **effective on:** Not available
- **summary:** 09-0114 response to TRG Inc. concerning 172.407.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-09-0114.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-09-0114.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-09-0114
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2009/090114.pdf
**body:**

<<<PAGE 1>>>

U.S. Department of Transportation
Pipeline and Hazardous Materials
Safety Administration
1200 New Jersey Ave, S.E.
Washington, D.C. 20590
Mr. Robert E. Sever
VP of Engineering
TRG Inc.
4150 Carr Lane Ct.
St. Louis, MO 63119
MAY 1 9 X)09
Ref. No. 09-0114
Dear Mr. Sever:
This is in response to your letters of May 11 and 15,2009, and our meeting on May 14,
concerning colors used by your company to print Oxygen labels onto the sidewalls of
cylinders for medical oxygen.
You submitted a number of printed samples of various shades of yellow for the Oxygen label
for our review, to determine conformance with the color standards for labels set forth in the
Hazardous Materials Regulations (HMR; 49 CFR 171-180) in Subpart E and Appendix A of
Part 172. You also submitted an Engineering Report analyzing, by spectrophotometer, 16
samples printed on a cylinder to determine which shade of yellow, if any, would match the
central color on the DOT Yellow Color Tolerance Chart. As you indicate in your May 15
letter, it was felt that the test results of a spectrophotometer would be less subjective than
comparing color chips.
The test results from the Engineering Report indicate that the number 7 shade of yellow on
the sample cylinder is a very close match to the central color on the DOT Yellow Color
Tolerance Chart. Based on these results and our review, we agree that sample number 7 is the
best color match and conforms to the color standards of the HMR.
I trust this information is helpful. If we can be of further assistance, please contact us.
Sincerely,
gL.l9/9f9c&
Edward T. Mazzullo
Director, Office of Hazardous
Materials Standards

<<<PAGE 2>>>

US Respiratory Pacific Cylinders Penox Technologies EMS+
4150 CARR LANE COURT SAINT LOUIS MO 631 19 USA. 314.659.43001p 877.877.37741~ 314.645.04991f
www.respirator~qroup.com
Mr. Edward Mazzullo, Director
Office of Hazardous Materials Standards
Office of Hazardous Materials Safety
Pipeline and Hazardous Materials Safety Administration
U.S. Department of Transportation
1200 New Jersey Avenue, SE
East Building, 2nd Floor
Washington, DC 20590
Attention: PHH-10
Dear Mr. Mazzullo,
Thank you for updating me on the letter that we requested, stating it would be acceptable to
place a yellow oxygen label over the current oxygen label printed on the cylinder. I look forward
to receiving it on Monday.
I n our meeting on -Thursday, I was asked to take a sample cylinder with the 16 shades of
yellow and have it analyzed with a Spectrophotometer to determine which shade of yellow, if
any, would match the central color on the DOT Yellow Color Tolerance Chart. It was felt that
the test results of a Spectrophotometer would give us a positive result and be less subjective
than comparing color chips.
After our meeting on Thursday, I contacted our Engineering Department and asked them to
take the sample cylinder to a lab that could compare the 16 shades of yellow on the cylinder to
the DOT Yellow Color Tolerance Chart. The results of the test indicate that the number 7 shade
of yellow on the sample cylinder is a very close match to the central color on the DOT Yellow
Color Tolerance Chart. I have attached a copy of the Engineering Report for your review.
I look forward to hearing from you after you have had a chance to look over the test report.
I would like to thank you and all of the DOT associates that have helped us resolve this issue.
Sincerely
Robert E Sever
VP of Engineering
TRG Inc.
4150 Carr Lane Ct.
St. Louis, MO 63119 USA
Work 314-659-4321
Cell 314-753-4404
DIAMOND SPRINGS, CA
800.390.14191p
530.621.20331f
MONTEBELLO, CA ST. LOUIS, MO NEW ALBANY, MS PITTSTON, PA
323.725.17061~ 877,877,37741~ 662.538.6500P 800.233.30291p
323.725.17881f 314.645.04991f 662.538.6561F 570.655.2036K

<<<PAGE 3>>>

DOCUMENT NUMBER ER090515
ENGINEERING REPORT ON
COLOR MATCHING OF YELLOW LABEL
PER 49 CFR 172 APPENDIX A
THE RESPIRATORY GROUP.COM
THE RESPIRATORY GROUP
4150 Carr Lane Ct.
St. Louis, MO 63119
ST. LOUIS, MISSOURI
ENGINEERING REPORT
ON COLOR MATCHING OF YELLOW LABEL

<<<PAGE 4>>>

The purpose of this report is to determine what shade of yellow is
most appropriate for use on the yellow oxygen label used on medical
oxygen cylinders.
1 .I Test Samples
Sixteen yellow labels were applied to two separate M6 cylinders. Each label had
a different shade of yellow.
One cylinder was used for color testing and the second was given to Helen
Engrum at the Office of Hazardous Materials Standards.

<<<PAGE 5>>>

2.0 CONCLUSIONS AND RECOMMENDATIONS
1. Of the sixteen shades of yellow, sample 7 was the closest match to the
Central Yellow color.
2. The Lab coordinates of sample 7 were:
a. L = 75.957143
b. a* = -2.9557143
c. b' = 67.572857
3. The Lab coordinates of the Central Yellow color printout were:
a. L = 78.73
b. a = 0.47
c. b = 69.94
4. The difference, or AE, between the two colors is 2.45.
5. The third party test lab, Group 360 Visual Communications, listed sample 7
as a good visual match to the Central Yellow Color due to the AE of 2.45.
Their general guidelines are as follows:
a. AE of 0-3 is a good visual match
b. AE of 3-7 is a fair visual match
c. AE greater than 7 is a poor match
6. The RGB values used to print Sample 7 on the cylinder were:
a. R = 255
b. G = 222
c. B = O
7. Any cylinder labeling applied by 'TRG after May 15, 2009 will have a warning
label with the same color shade of yellow as sample 7.
3.0 TESTING
3.1 Test Procedure
The printed cylinder and a copy of the DOT Yellow Color Tolerance Chart,
referenced by 49 CFR 172 Appendix A, was sent to a third party test lab.
Each of the 16 yellow labels printed on the cylinder were compared to the
Central Color on the Yellow Color Tolerance Chart.
The analysis of the colors was done using an X-RITE 528 Spectrophotometer.
The color coordinates were read using the ClELab coordinate system.
3.2 Test Results
See Appendix for test results.

<<<PAGE 6>>>

APPENDIX
SIZE
FSCM
DRAWING NO.
REV
A
ER090515
SCALE
SHEET
4 OF 4

<<<PAGE 7>>>

VISUAL COMMUNICATIONS
Orion Oxygen Yellow 5/14/09
- #
b*
mis chart show the dilferenm in hue from the target cola. The center m e pofnl
represents no change. Any change horn center in&caler a change in that direcllon.
Thil* 01 it a9 adding ermr hue to the target cdor.
This chart s h w the difference in lightms
rrom the target cola. Up belng lighter and
dom being darker.

<<<PAGE 8>>>

THE RESPIRATORY GROUP
US Respiratory Pacific Cylinders * Penox Technologies * EMS+
4150 GARR LANE COURT SAINT LOUIS MO 631 19 USA 314.659.4300/p 877.877.3774lp 314.645.049911
www.resairatowaroup.com
May 11, 2009
Mr. Edward Mazzullo, Director
Office of Hazardous Materials Standards
Office of Hazardous Materials Safety
Pipeline and Hazardous Materials Safety Administration
U.S. Department of Transportation
1200 New Jersey Avenue, SE
East Building, 2nd Floor
Washington, DC 20590
Attention: PHH-10
Dear Mr. Mazzullo,
I had a very nice conversation with Ms. Helen Engrum today. We appreciate her time with me
to address the issue of the color of yellow we have on our current oxygen cylinder label.
I sent samples of the label printed on the cylinder to DOT on May 5'h 2009 for review after a
gas company refused to fill our customer's cylinders. After examining the cylinders, Ms.
Engrum called me today to inform me that it was the opinion of the DOT that the color of
yellow used on the label was incorrect. Although we do not agree with this, we understand that
we have two options with regard to the cylinders already in the fields.
1) Request permission to use the 6,836 cylinders currently in the field as is by applying
for a "Special Permit" for this quantity. All future labels would use a shade of yellow
more agreeable to the DOT.
2) The second option was to place a label with a more agreeable shade of yellow over
the existing label currently on 6,836 cylinders in the field.
We would prefer that DOT grant permission to use the cylinders, as is, however we are not sure
how long this process would take. Our customer is in a difficult position needing oxygen for its
patients, so we must resolve this as quickly as possible. Please advise.
With regard to the second option, the gas company filling the cylinders informed me that they
would not fill the cylinders if we installed a label over the existing label unless we received
approval from the DOT in writing to do so. If we received such permission in writing, this
would certainly alleviate our current dilemma for the moment. Please advise as to this option.
DIAMOND SPRINGS, CA MONTEBELLO, CA ST. LOUIS, MO NEW ALBANY. MS PITTSTON, PA
800 390.14191p 323.725.1 7061p 877.877.37741~ 662538.65DOP 800,2)23029/p
530.621 .XI338 323 725,178811 314.645.0499n 662.538.6561F 570.655.20361f

<<<PAGE 9>>>

THE RESPIRATORY GROUP
US Respiratory * Pacific Cylinders * Penox Technologies EMS+
4150 CARR LANE COURT SAINT LOUIS MO 631 19 USA 314.659.4300lp 877,877,37741~ -314.645.0499ff
www.res~iratomrou~.com
I would also like to send you a sample of a shade of yellow we are considering using on the
label to make sure we are in agreement and that the DOT would not object to this new shade
of yellow.
I would like to thank you and all of the DOT associates for your time on this issue. We would
appreciate an immediate response since we have an issue which needs immediate attention.
Robert E Sever
VP of Engineering
TRG Inc.
4150 Carr Lane Ct.
St. Louis, MO 631 19 USA
Work 314-659-4321
Cell 3 14- 753-4404
DIAMOND SPRINGS, CA MONTEBELLO. CA ST. LOUIS, MO NEW ALBANY, MS PITTSTON, PA
800.390.14191p 323.725.1 7061~ 877 877.37741~ 662.538.650W 800.233.30291p
530.621 203311 323.725 1 7 8 1 314.645.0499lf 662.538.6561F 570.655.20366

<<<PAGE 10>>>

THE RESPIRATORYGROUP.COM
4150 Can Lane Court, St. Louis, MO 63 1 19
Phone: (3 14) 659-4300
Customer Service: (877) 877-3774 or (888) 443-7210
Fax: (314) 645-0499 Toll Free Fax: (888) 207-8802
1. TO: Associate Administrator for Hazardous Materials Safety
Pipeline and Hazardous Materials Safety Admin
U.S. Department of Transportation
1200 New Jersey Avenue, SE, East Building, 2nd Floor (PHH)
Washington, DC 20590
Attention: PHH-3 1
2. FROM: The Respiratory Group, Inc. (TRG)
4 150 Carr Lane Ct.
St. Louis, MO 63 1 19
TRG Agent: Bob Sever 3 14-659-4321
3. I f the applicant is not a resident of the United States, the applicant must designate an
agent for service in accordance with 49 CFR 105.40.
Does not apply.
4. For a manufacturing special permit, one must provide a statement of the name and
street address of each facility where manufacturing under the special permit will
occur.
Cylinders and their labeling are manufactured at the TRG facility.
5. I f confidential treatment is requested, the applicant must comply with 49 CFR
105.30(a).
Confidential treatment is not required.
6. State the citation(s) of the specific regulation from which relief is sought.
49 CFR 172.407(d)(4) is the citation for which TRG is seeking a special permit for a
modification.
7. Specify the proposed mode or modes of transportation.
The modes of transportation are by standard freight and trucking lines.

<<<PAGE 11>>>

THE RESPIRATORY GROUP.COM
4150 Carr Lane Court, St. Louis, MO 631 19
Phone: (3 14) 659-4300
Customer Service: (877) 877-3774 or (888) 443-7210
Fax: (314) 645-0499 Toll Free Fax: (888) 207-8802.
8. Provide a detailed description of the proposed special permit (e.g., alternative
packaging, test, procedure or activity) including, as appropriate, written descriptions,
drawings, Jaw charts, plans and other supporting documents.
The color of the Oxygen label used on a medical oxygen cylinder is
supposed to be within a range of colors given by the color data shown in
Appendix A, Table 1 of CFR 172. The color, Pantone 109U, may also be
used to achieve these colors.
Samples of the 6836 cylinders, that are already manufactured, have been sent to DOT
for assessment of the yellow shade used. The shade of yellow was deemed to be
unacceptable. For this reason, we asking for this special permit to use the cylinders
as-is.
9. Specify the proposed duration or schedule of events for which the special permit is
sought.
The special permit is for 6836 cylinders. Future manufacturing would incorporate a
yellow label with a shade approved by DOT.
10. Provide a statement outlining the applicant's basis for seeking relief from compliance
with the specified regulations and, if the special permit is requested for afixed
period, a description of how compliance will be achieved at the end of that period.
TRG is seeking relief from this compliance in order to supply the end-user with
oxygen in a timely fashion.
1 1. v a n emergency special permit is requested, the applicant must comply with 49 CFR
107.11 7 and provide a statement of supporting facts and reasons.
An emergency special permit is being requested so that any delays supplying oxygen
to the end-user will be minimized. These delays can result in oxygen therapy patients
experiencing health problems due top hypoxia.
12. Identify and describe the hazardous materials planned for transportation under the
special permit.
High Pressure Medical-grade Oxygen will be transported in the cylinders.

<<<PAGE 12>>>

THE RESPIRATORY GROUP.COM
4150 Carr Lane Court, St. Louis, MO 631 19
Phone: (3 14) 659-4300
Customer Service: (877) 877-3774 or (888) 443-721 0
Fax: (314) 645-0499 Toll Free Fax: (888) 207-8802
13. Provide a description of each package, and include a specification or special permit
number, as applicable, to be used in conjunction with the requested special permit.
The package is an aluminum cylinder designed to store and transport high-pressure
medical oxygen.
14. For alternative packagings, the applicant must provide documentation of quality
assurance controls, package design, manufacture, performance test criteria, in-
service performance and service-life limitation.
Not applicable
15. The application must demonstrate that a special permit achieves a level of safety at
least equal to that required by regulation, or i f a required safety level does not exist,
is consistent with the public interest.
The risks involved in granting the shade of yellow used to print the oxygen label on
the 6836 cylinders are no greater than a label printed with exactly the correct color.
The shade used is definitely a shade of yellow. The only debate is to whether it is
within a pre-determined tolerance of yellow shades.
In a real world application, this becomes irrelevant to the end-user as they can clearly
read the text, "OXYGEN" on the label.
- **truncated:** false
- **body characters:** 14524