# Air Liquide America Specialty Gases LLC — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 09-0265
- **title:** Air Liquide America Specialty Gases LLC — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2010-01-27
- **effective on:** Not available
- **summary:** 09-0265 response to Air Liquide America Specialty Gases LLC concerning 173.302a.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-09-0265.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-09-0265.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-09-0265
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2009/090265.pdf
**body:**

<<<PAGE 1>>>

U.S. Department 1200 New Jersey Ave., SE
of Transportation Washington, DC 20590
Pipeline and Hazardous Materials
Safety Administration
JAN 2 7 2010
Mr. Ralph Diaz
Air Liquide America
Specialty Gases LLC
2700 Post Oak Blvd.
Houston, TX 77056
Ref. No. 09-0265
Dear Mr. Diaz:
This responds to your e-mail regarding the reuse of a cylinder under the Hazardous Materials
Regulations (HMR; 49 CFR Parts 171-180). Specifically, you ask under what condition the
HMR authorize a cylinder previously used in carbon monoxide (CO) service to be refilled
with a high-purity gas such as helium, argon, or hydrogen. Additionally, you ask whether the
HMR define the term "dry," as used in § I 73.302a(c).
When promulgating regulations regarding the filling and transportation of cylinders used
exclusively in CO service, we did not foresee the need to codify any condition or minimum
qualification for the continued use of such cylinders in another gas service. Although the
HMR do not prohibit such practice, PHMSA strongly discourages it for safety reasons. For
example, the moisture in CO may cause internal micro-cracking of the cylinder. Such
cracking may not be detected through internal visual inspection or hydrostatic testing.
Therefore, until a regulatory solution is adopted, we recommend the following tests be
performed, at a minimum, if considering a change in gas service:
1. Proof pressure test equal to test pressure of the cylinder with a minimum of one (1)
minute hold time; and
2. 100% side wall ultrasonic examination (UE) using shear wave with accept/reject
criteria of 5% of design minimum wall thickness.
Ten percent overfill of the cylinders is not recommended. The term "dry," as used in
§ 173.302a( c), is not defined in the HMR. For the purposes of § 173.302a( c), "dry" means a

<<<PAGE 2>>>

gas having a dew point at or below -46.7 °C (-52 OF) at 101.3 kPa (14.7 psia) (one
atmosphere).
Thank you for bringing this matter to our attention. If we can be of further assistance, please
contact this office.
Sincerely,
.~
Hattie L. Mitchell
Chief, Regulatory Review and Reinvention
Office of Hazardous Materials Standards
2

<<<PAGE 3>>>

Page 1 of 1
Drakeford, Carolyn (PHMSA)
From: Mitchell, Hartie (PHMSA) 'S+e\let1S
Sent: Thursday, November 12, 200911:58 AM
To: Drakeford, Carolyn (PHMSA)
~ 113 ·302a.. (ej
Subject: FW: 49CFR173.302a(c) ~ 11'r1c1ers
From: Diaz, Ralph [mailto:Ralph,Diaz@Airliquide,com] ~q-OLloS
sent: Thursday, November 12, 2009 11:01 AM
To: Toughiry, Mark (PHMSA); Mitchell, Hattie (PHMSA); Cassidy, Duane (PHMSA); Chaney, Wayne (PHMSA)
Subject: 49CFR173,302a{c)
Not sure of proper DOT dept. to answer the following:
49CFR173.302a{c} limits the pressure (to 5/6 service pressure) of cylinders filled with dry carbon monoxide and
also limits the pressure further (to only 1000 psi) of cylinders of 'wet' carbon monoxide.
Questions:
What is DOT's intent on the disposition and continued use of these cylinders when LATER filled with other clean
high purity gases like helium, argon, hydrogen, etc? Can the same cylinders be filled to full service pressure with
these 'clean gases', filled to 10% overfill, etc. provided hydrotest is acceptable for these filling operations? Was it
the intent of DOT to limit the filling pressure of all gases once exposed to carbon monoxide?
Did DOT ever define 'dry'?
Regards,
Ralph Diaz
11112/2009
- **truncated:** false
- **body characters:** 3377
