# Mr. John Cox — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 10-0019R
- **title:** Mr. John Cox — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2011-01-07
- **effective on:** Not available
- **summary:** 10-0019R concerning 180.205, 180.209.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-10-0019r.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-10-0019r.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-10-0019r
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2010/100019-R.pdf
**body:**

<<<PAGE 1>>>

U.S. Department of Transportation Pipeline and Hazardous Materials
Safety Administration
1 200 New Jersey Ave, SE
Washington, D.C. 20590
JAN 7 1.011
Mr. John Cox
Fire Chief
P. 0 Box 21
Jamaica, Iowa 50128
Ref. No.: 1O-0019-R
Dear Mr. Cox:
It has been brought to our attention that our response to your January 31 email regarding the
condemnation criteria in the Hazardous Materials Regulations (HMR; 49 CFR parts 171-180)
applicable to DOT-3AL cylinders manufactured of6351-T6 aluminum alloy was incomplete.
Specifically, you asked about conflicting condemnation criteria in § 180.209(m), Appendix C ofPart
180, and CGA Pamphlet 6.1 regarding these cylinders.
In our April 28, 2010 letter, Ref. No.: 10-0019, we said the following:
Section l80.205(t)(4) requires each specification cylinder manufactured of 6351-T6
aluminum alloy used in self-contained underwater breathing apparatus (SCUBA), selfcontained
breathing apparatus (SCBA), or oxygen service to be inspected for sustained load
cracking (SLC) in accordance with Appendix C of Part 180 every five years. The inspection
must include both a visual inspection and an eddy current examination. Each cylinder with
SLC that has expanded into the neck threads must be condemned in accordance with
§ 180.205(i). That is, the cylinder must be condemned when evidence of cracking exists to
the extent that the cylinder is likely to be weakened.
As prescribed in Appendix C of Part 180, visual examination ofthe neck and shoulder area of
the [DOT 3AL] cylinder (described above] must be conducted in accordance with CGA
Pamphlet 6.1. Cylinders with cracks must be condemned, and repair ofneck cracks is not
allowed. If the visual inspection does not identify cracks in the neck and shoulder area that
would require condemnation ofthe cylinder, it must be subjected to an eddy current
examination. Ifthe eddy current examination reveals any crack in the neck or shoulder area
of two thread lengths or more, the cylinder must be condemned.
In our April 28, 2010 response, we inadvertently provided partial information in the last sentence of
the last paragraph. This letter is intended to clarify the requirements regarding condemnation criteria

<<<PAGE 2>>>

specified in Appendix C of Part 180. The correct response is "[I]f the eddy current examination
combined with a visual inspection reveals any crack in the neck or shoulder area of two thread
lengths or more, the cylinder must be condemned". Therefore, the letter designated as Ref. No.:
10-0019 is retracted and replaced by this letter, Ref. No.: 1O-OO19-R.
We apologize for any misunderstanding, and hope that it has not caused any inconvenience.
r\ Charles E. ;etF0::'
~l;/A'
Director
b Standards and Rulemaking Division
cc: Fred A. Nachman

<<<PAGE 3>>>

October 26, 2010
Mr. Delmer Billings
Director, Special Permits and Approvals
delmer. billings@dot.gov
Mr. Charles Hochman,
Director, Technology
charles.hochman@dot.gov
Mr. Mark Toughity
Mechanical Engineer, Technology
mark. tougbi.[y@dot.gov
Mr. Edward Mazzullo, Director
Hazardous Materials Standards
Edward.mazzullo@dot.gov
Mr. Charles Betts, Chief
Standards Development
Charles.betts@dot.g9v
Mr. Wayne Chaney
Special Investigations
Wayne.chaney@dot.gov
Mr. Ryan Posten
Assistant Associate Administrator
Ryan.posten@dot.gov
U. S. Department of Transportation- PHMSA
1200 New Jersey Ave S.E.
Washington, D. c., 20590-0081
Subject: Request for Clarification of PHMSA Letter of Interpretation No. 10-0019 reo
Eddy Current Condemnation Criteria
PHMSA Interpretation # 1 0-00 19 dated April 28, 2010 attempte~ to clarify the issue of
conflicting condemnation criteria by stating that "If the eddy current examination reveals any
crack in the neck or shoulder area oftwo thread lengths or more, the cylinder must be
condemned." The wording and apparent intent does not allow for any visual confirmation of
those flaws in the neck/thread area. Eddy current examination does not inspect the shoulder area
for flaws.
1

<<<PAGE 4>>>

49CFR180 Appendix C(5) Condemnation Criteria reads ... A cylinder must be condemned if
the eddy current examination combined with visual examination reveals any crack in the neck or
shoulder of2 thread lengths or more.
It is our clear understanding of 49CFR180 that a cylinder which fails either hydrostatic test or
visual inspection must be condemned. The referenced interpretation No. 10-0019 for VE
examinations seems to imply the same thing, i.e., if a cylinder fails hydro, visual inspection or
eddy current examination, it must be condemned. 49CFR180 Appendix C(5) does not say "or"
which would clearly require the requalifier to condemn any 6351-T6 cylinder in SCBA, Scuba or
oxygen service whenever a crack in the neck or shoulder area of 2 threads or more is indicated in
the eddy current scans, regardless ofwhether or not it can be visually confirmed.
The Sept/2000 Nondestructive Inspection of High Pressure Aluminum Gas Cylinders
Report, page 37, prepared for Mark Toughiry at DOT reads ... Ifthe flaw is not visually
detected, it is deemed to be a false positive on the part ofthe eddy current system so the cylinder
is not rejected based on this false positive. Table 4-1 showed the comparisons of effective
identification of flaws by visual vs. eddy vs. UE in detecting neck cracks. Our reading showed
visual inspection to pick up as many flaws as eddy examination without false positives.
Discussions at CGA Cylinder Spec meetings when this regulation was being promulgated also
lead us to understand that the Eddy Exam required Visual Confirmation.
Condemnation criteria quoted above which used the language "combined with" did not use the
word "or" or "and/or" which would have made it perfectly clear that you could not override an
eddy current scan even if the visual did not confirm.
It is our understanding that eddy current machines are not capable of checking the shoulder area
ofa medical cylinder- only the thread area. That area as well as any thread indications can be
picked up and viewed with an Optical-Plus magnification light. .
It is our understanding that it is difficult for the eddy current machine to differentiate a crack
from a tool stop. See Figures 10 and 11 in CGA C6.1- 2006. Accordingly, the visual OpticalPlus
light is needed to confirm it to preclude unnecessary condemnations.
VE examination scans also pickup indications from corrosion, dirt, thread folds, tool stops, etc ..
How would the requalification process preclude unnecessary condemnation of 6351-T6 cylinders
if a visual with a magnified Optical-Plus Light or some other equivalent device wasn't utilized to
confirm a true condemnable defect picked up on the VE scan?
We also question the regulation in its exemption of C02 cylinders from this requirement as we
find a significant percentage of neck cracks that are rejected visually? While they are in a lower
pressure service, they do expand and blow PRDs in high temperature Arizona environments.
Our mission at Thunderbird is to be compliant and safe without unnecessarily condemning our
clients' fleet of6351-T6 aluminum cylinders. Our clients rely on our integrity and diligence to
understand and comply with Federal codes and best practices when requalifying their cylinders.
Accordingly, we were confused by the letter of interpretation. Since we knowlingly overrode
visual eddy indications when unconfirmed by visual, are we subject to DOT sanctions of fines,
incarceration and loss of authorization? What was our liability should injury or death occur?
Would we lose the trust of our clients and regulators, if we did not do the right thing? Should we
2

<<<PAGE 5>>>

ignor past requalifications and just change our procedures moving forward, thus exposing our
customers and their clients to noncompliant requalifications and possible injury? Should we
report our violation ofthe code to DOT as interpreted by 10-00 19?
Our decision, first, was to review and the codes and referenced materials. Second, we made a
weekend review ofall our computerized eddy current scans and overrides to understand the
extent of this change and prepare a recall notice to get those cylinders back for reexamination
and condemnation. Third, we prepared this request to ask what is our requirement as to advising
DOT? How could we get this issue clarified promptly so we could move forward with the
correct procedures as well as how to handle the past requalifications? Not only are we confused,
but we are also embarrassed as we base our reputation of knowing these answers?
We were advised to recall the recall until clarification is received from DOT as other
knowledgeable requalifiers, customers and a manufacturer of these cylinders had similar
misunderstandings of the regulations. We request a prompt response so we can advise our
personnel on how to proceed with future examinations which could result in a 35%
condemnation rate of 6351-T6 cylinders. And, finally, we again request that DOT sets up an
Email distribution list of all its authorized requalifiers to distribute code changes and letters of
interpretation when they are issued.
Respectfully submitted,
Fred A. Nachman
President