# Mr. Juan Gonzalez — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 10-0091
- **title:** Mr. Juan Gonzalez — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2010-10-20
- **effective on:** Not available
- **summary:** 10-0091 concerning 173.301, 180.213.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-10-0091.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-10-0091.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-10-0091
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2010/100091.pdf
**body:**

<<<PAGE 1>>>

U.S. Department of Transportation Pipeline and Hazardous Materials
Safety Administration
OCT 20 2010
1200 New Jersey Ave, SE
Washington, D.C. 20590
Mr. Juan Gonzalez
Calle 29 # 17 B 100 Casa 4
EI Retiro - Antioquia
Colombia
Reference No. 10-0091
Dear Mr. Gonzalez:
This is in response to your request for clarification ofthe Hazardous Materials Regulations (HMR;
49 CFR Parts 171-180) applicable to certain cylinder marking requirements. Your questions are
paraphrased and answered below.
Ql. Section 173.301(b) (Note: your e-mail refers to the out-of-date cite, § 173.34. The
information was moved to § 173.301 in a final rule, "Hazardous Materials: Requirements for
Maintenance, Requalification, Repair and Use of DOT Specification Cylinders," HM-220D,
67 FR 51652, published August 8, 2002.) states that additional information may be marked
on the cylinder provided it does not affect the required markings prescribed in the applicable
cylinder specification. What type of additional information is referred to in this statement?
A1. Section 173.30 1 (b) refers to any information that is not required. The non-required
additional information may not diminish or obstruct the required information. In addition,
§ 178.35(f) addresses additional marking requirements for specification cylinders.
Additional markings include those that are not required in Part 180 of Subpart C and
§ 178.35(f).·
Q2. Who is authorized to place information on the cylinder?
A2. The application ofrequalification markings required under the HMR are only authorized by
individuals meeting the requirements ofPart 107, Subpart I, "Approval ofIndependent
Inspection Agencies, Cylinder Requalifiers, and Non-domestic Chemical Analyses and Tests
ofDOT Specification Cylinders."
Q3. Is the indentation of new information over the surface where original information was
initially stamped acceptable?
A3. Requalification markings inust conform to requirements in § 180.213, including maintaining
the minimal wall thickness and specifications for the marking size and location. Generally,

<<<PAGE 2>>>

all specification markings must be maintained, legible, and visible at all times. Previous
requalification markings may not be obliterated except as provided in § 180.213(b )(2).
I hope this information is helpful. Please contact this office should you have additional questions.
Sincerely,
rr4~~
T. Glenn Foster
Chief, Regulatory Review and Reinvention
Office of Hazardous Materials Standards

<<<PAGE 3>>>

Drakeford. Carolyn (PHMSA)
From: INFOCNTR (PHMSA)
Sent: Friday, April 23, 201012:06 PM 
 Jo- 009I
To: Drakeford, Carolyn (PHMSA)
Subject: FW: Question about CFR 49 part 173.34
Carolyn,
Thanks,
Rob
This gentleman would like a written letter of interpretation based on the emails contained below.
From: Juan Carlos Gonzalez Velez [mailto:gonzaljk@yahoo.com]
Sent: Friday, April 23, 2010 12:01 PM
To: INFOCNTR (PHMSA)
Cc: masanchez@andi.com.co
Subject: Re: Question about CFR 49 part 173.34
This morning called up to the numbers provided by you in the US and I had a phone conversation
with a Subject Matter Expert who guided me in a very detailed way. Thanks for that.
Can you please send a WRITTEN RESPONSE to my questions bellow? I really appreciate your
assitance.
Best Regards,
Juan Gonzalez.
From: Juan Carlos Gonzalez Velez <gonzaljk@yahoo.com>
To: INFOCNTR@dot.gov
Sent: Fri, April 23, 2010 9:30:53 AM
Subject: Re: Question about CFR 49 part 173.34
Thank you for your prompt response.
My question is basically about seamless cylinders used to fill and transport industrial and medical
gases at high pressure. I will be happy to speak with a subject matter expert in this field, so thanks for
the phone # given, I will be ringing soon.
My phone number is +57 311 7645952, you can reach me any time. Thanks again
Best regards,
Juan Gonzalez
From: "INFOCNTR@dot.gov" <INFOCNTR@dot.gov>
To: gonzaljk@yahoo.com
Sent: Fri, April 23, 2010 8:28:00 AM
Subject: RE: Question about CFR 49 part 173.34
Dear Juan Carlos Gonzalez Velez,
We have received your inquiry about the hazardous materials regulations (49 CFR Parts
171-180). The hazardous materials regulations are available at the following URL:
.htm
1

<<<PAGE 4>>>

A hazardous materials regulatory specialist would be happy to speak with you regarding
your inquiry. You may contact the Hazardous Materials Information Center, which is
staffed with regulatory who can quickly answer your ions phone,
Monday through Friday, 9 AM - 5 PM EST at (800) 467 4922 or (202) 366-4488.
Alternatively, if you would like a regulatory specialist to contact you directly, please
respond to this e-mail with a telephone number where you can be reached between 9 AM and
5 PM EST.
Sincerely,
Robert Benedict, Hazardous Materials Specialist
An e-mail response from this office is considered informal guidance. Formal guidance may
be requested in accordance with 49 CFR 105.20.
From: Juan Carlos Gonzalez Velez [mailto:gonzaljk@yahoo.com]
Sent: Thursday, April 22, 2010 5:40 PM
To: contactcenter@gpo.gov; INFOCNTR (PHMSA)
Cc: masanchez@andi.com.co
Subject: Question about CFR 49 part 173.34
I do not know if you are the right department to ask for this information but just in case is not your business,
please pass this message to the appropriate department or person who deals with questions asked to regulations
boards in the TRANSPORTATION field.
I am sending this message to three agencies (GPO, NARA by another means, and DOT to whom I also sent this
question through its web page) that may offer some assistance. Please respond even ifthe three of you have a
response.
Reading CFR 49 part 173.34 about qualification, maintenance and use of cylinders, a doubt comes up regarding
the nature of additional information that may be placed on the cylinder. Basically note (C-1) about cylinder
marking says: "Additional information not affecting the markings prescribed in the applicable cylinder
specification may be placed on the cylinder. No indentation may be made in the sidewall of the cylinder unless
specifically permitted in the applicable specification". My questions are:
1. What type of additional information is referred to here?, Is it additional to the original one when
cylinder was manufactured. If that is the case, could it be even original information that is becoming
illegible because of its usage?
2. Who is authorized to place such information on the cylinder, and what kind of tests may endorse the
new information stamped?
3. Is it reasonable to accept indentation of new information over the surface where original information
was initially stamped?
Thanks in advance for your prompt response.
Juan Gonzalez