# Integrity Inspection Services — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 10-0174
- **title:** Integrity Inspection Services — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2010-09-03
- **effective on:** Not available
- **summary:** 10-0174 response to Integrity Inspection Services concerning 173.443.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-10-0174.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-10-0174.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-10-0174
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2010/100174.pdf
**body:**

<<<PAGE 1>>>

U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration
SEP 3 2010
1200 New Jersey Ave, SE
Washington, D.C. 20590
~r.JanaesJagernann
Integrity Inspection Services
21422 Provincial Boulevard
Katy, TX 77450
Ref. No. 10-0174
Dear ~r. Jagernann:
This responds to your August 12,2010 enaail regarding the transportation ofradioactive·
naaterial under the Hazardous ~aterials Regulations (H~R; 49 CFR Parts 171-180).
Specifically, you request clarification ofthe naethod of calculation used to deternaine the level of
contanaination on the external surfaces ofa package in accordance with § 173.443 ofthe HMR.
Your question is paraphrased and answered as follows:
For instances when the wipe efficiency is assunaed to be 0.10, ifthe instrunaent used to naeasure
radioactivity provides a reading in counts per nainute (cpna), do I need to include a factor to
convert cpna to disintegrations per nainute (dpna) or does the assunaed 0.10 wipe efficiency
incorporate a conversion frona cpna to dpna?
In addition to the assunaed 0.10 wipe efficiency, an instrunaent efficiency factor is needed to
calculate the contanaination activity on the wiping naaterial. The wipe efficiency factor does not
account for the effectiveness ofthe instrunaent in naeasuring radioactivity. The instrunaent
efficiency factor is a function ofthe efficiency ofthe specific instrunaent in naeasuring the
radioactivity on the wiping naaterial. This instrunaent efficiency factor naay be provided on the
instrunaent, obtained through the naanufacturer or supplier ofthe instrunaent, or deternained by
using reference standards ofknown radioactivity. Therefore, in your case, both a wipe
efficiency factor and an instrunaent efficiency factor are needed to calculate the level of
contanaination in dpna.
I hope this infornaation is helpful. Ifyou have further questions, please contact this office.
Sincerely,
<BWt~~
Ben Supko
Acting Chief, Standards Developnaent
Office ofHazardous Materials Standards

<<<PAGE 2>>>

Drakeford, Carolyn (PHMSA)
From: INFOCNTR (PHMSA) KANl
Sent: Friday, August 13, 2010 9:00 AM 10- Oli'f
To: Drakeford, Carolyn (PHMSA)
Cc: DerKinderen, Dirk (PHMSA)
Subject: FW: Hazmat Information Center Feedback: General Information, Regulations, and Definitions
(Sections 171.1 &ndash; 171.26)
-----Original Message----From:
PHMSA-Feedback [mailto:PHMSA-Feedback]
Sent: Thursday, August 12, 2010 1:05 PM
To: PHMSA HM InfoCenter; PHMSA Webmaster
Subject: Hazmat Information Center Feedback: General Information, Regulations, and
Definitions (Sections 171.1 &ndash; 171.26)
I would like to obtain clarification for the calculation of NORM loose surface contamination
for DOT purposes is correct.
Per the regulations:
Removable (loose) contamination levels shall be established by w1p1ng an area of 300cm2 of
the surface concerned with an absorbent material, using moderate pressure, and measuring the
activity on the wiping material. Sufficient measurements must be taken in the most
appropriate locations to yield a representative assessment of the non-fixed contamination
levels. [49CFR173.443(a) (1)]
The amount of radioactivity measured on any single wiping material, divided by the surface
area wiped and the efficiency of the wipe procedure (the fraction of removable contamination
transferred from the surface to the absorbent material), may not exceed 22 dpm/cm2 alpha or
220 dpm/cm2 beta/gamma. For this purpose the actual wipe efficiency may be assumed to be
0.10. [49CFR173 .443 (a)(1) ]
If using the above regulations, the loose surface calculation would be:
cpm/300/0.1/ = dpm/cm2
where:
• cpm = meter reading
• 300 = wipe area cm2
• 0.1 wipe efficiency
My question is, do I also need to input a factor for converting cpm to dpm due to the fact
that the field survey instrument used to count the smear reads out in units of cpm or does
the above wipe efficiency assumption include that conversion?
Thank you for your help in this matter.
~~~~~li~~~~ Jageman~
Email: james.jagemann@yahoo.com
Phone: 713-885-2745
1:-k Jr-{f1 ~ ~p e.J ~t.h Su VILL':;:.
7l'lz '- P('~"' '''c-~ t 6l,J.
~ r {efti5 77150 1
- **truncated:** false
- **body characters:** 4141
