# AVOX Systems Inc. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 10-0253
- **title:** AVOX Systems Inc. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2010-12-22
- **effective on:** Not available
- **summary:** 10-0253 response to AVOX Systems Inc. concerning 173.168, 173.56.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-10-0253.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-10-0253.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-10-0253
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2010/100253.pdf
**body:**

<<<PAGE 1>>>

U.S. Department of Transportation 1200 New Jersey Ave, SE
Washington, D.C. 20590
Pipeline and Hazardous Materials
Safety Administration
DEC 222010
Mr. Joesph Contino
A VOX Systems Inc.
225 Erie Street
Lancaster, PA 14086
Reference No.: 10-0253
Dear Mr. Contino:
This responds to your November 24, 2010 email regarding the requirements for the examination,
testing and approval of Chemical Oxygen Generators under the Hazardous Materials Regulations
(HMR; 49 CFR Parts 171-180). Your questions are paraphrased and answered as follows:
Q1. Does the requirement to have chemical oxygen generators examined in accordance with
§ 173.56, include the rigid outer packaging specified in § 173.168( d)?
AI: The answer is no. In accordance with § 173.168(a), a "chemical oxygen generator that is
shipped with an explosive or non-explosive means of initiation attached must be classed
and approved by the Associate Administrator in accordance with the procedures specified
in § 173.56 of this subchapter." The requirements in § 173.56 apply to the chemical
oxygen generator itself; not the packaging referenced in § 173.168( d). In accordance
with § 173.168(d), a chemical oxygen generator and a chemical oxygen generator
installed in equipment, (e.g., a Protective Breathing Equipment), when transported by
cargo-aircraft only, must be placed in a rigid outer packaging that is capable of
successfully passing the Flame Penetration Resistance Test specified in Appendix E and
the Thermal Resistance Test specified in Appendix D to part 178 of this subchapter.
These tests are performance oriented tests and are independent of the examination of the
chemical oxygen generator required by § 173.56.
Q2. If the rigid outer packaging does require this testing, does the testing have to be
performed by a competent authority laboratory?
A2. The answer is no. The rigid outer packaging must be able to successfully pass the Flame
Penetration Resistance Test specified in Appendix E and the Thermal Resistance Test
specified in Appendix D to part 178 of this subchapter. However, there is no requirement
for an approved laboratory to perform these tests.

<<<PAGE 2>>>

Q3 If the answer to 02 is yes: Are the various packaging providers which advertise, test,
mark and certify their packagings as HM-224B compliant for chemical oxygen
generators, without sending or referring the product and package to an approved lab,
doing so in compliance or in violation on § 173.168?
A3. See A2.
I hope this satisfies your inquiry. Please contact us if we can be of further assistance.
Sincerely,
T. Glenn Foster
Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division

<<<PAGE 3>>>

Drakeford, Carol
From: INFOCNTR (PHMSA)
Sent: Wednesday, November 24,20102:44 PIVI
To: Drakeford, Carolyn (PHMSA)
Subject: FW: Hazmat Information Center Feedback: Interpretations (Letters) Issued by PHMSA
Hi Carolyn,
Joseph Contino would like to submit the below request for a formal letter of interpretation.
He has spoken with HMIC staff previously, and was referred to the June 2009 advisory alert on
chemical oxygen generator packaging.
Thanks,
Victoria Lehman
202-366-1035
-----Original Message----From:
PHMSA-Feedback [mailto:PHMSA-Feedback]
Sent: Tuesday, November 23, 2010 3:18 PM
To: PHMSA HM InfoCenter; PHMSA Webmaster
Subject: Hazmat Information Center Feedback: Interpretations (Letters) Issued by PHMSA
BACKGROUND
AVOX Systems Inc., formerly known as Scott Aviation, has been manufacturing Chemical Oxygen
Generators (COG) products for the aviation industry for more than thirty years. AVOX has
previously received classification for these products as, oxygen generator, chemical, UN
3356, and UN classification code of 5.1. This classification bears reference number
EX1997080041 per RSPA letter dated September 23, 2004. We are currently shipping these
products per 49 CFR 173.168 in DOT31FP compliant containers in accordance with the new rule
HM224B.
We have made some minor changes and identified these new configurations with new part
numbers. The new series generators differ only in minor details of appearance and the
external fittings which interface with the aircraft they are intended to be installed in.
Improvements were also made to the chemical formulation that included the elimination of
Barium (Ba02) as required by current industry standards. The new series generators contain
the same basic chemicals however they were reformulated to replace the Barium (Ba02) with
Mn02, KMn04, and KOH and different inert binders and reaction moderators (Si02, Mica, MgO,
and Talc) that improve the overall COG performance.
We are having these new generators classed in accordance with 49 CFR 173.56 including testing
performed at an approved DOT test lab. Subsequent to the lab proposal and completing all
of the tests, the lab informed us that they had to perform additional testing per appendix D
and E of 173.168. We advised that we already had qualified packaging to meet this
requirement and provided copies of the test reports to the DOT approved lab. They informed
me that they could not accept the data because the lab that performed the testing was not a
competent authority lab. They said this even though there is no requirement for a competent
authority lab to qualify to meet 173.168 appendix D and E.
QUESTIONS:
1. Does the requirement to have the COG examined per 173.56, include the packaging testing
and certifying specified in 173.168 appendices D and E?
1

<<<PAGE 4>>>

2. If it does require this testing~ does the testing have to be performed by a competent
authority lab?
3. If the answer is yes: Are the various packaging providers which advertise~ test~ mark and
certify their packages as HM224B compliant for COG~s~ without sending or referring the
product and package to an approved lab~ doing so in compliance or in violation of 173.168?
A written response is requested.
Sincerely,
Joseph Contino
Director of Technology &Market Developmen AVOX SYSTEM INC.
225 Erie St. -
Lancaster~ NY 14e86 - USA
Tel: 716-686-1615
Joseph.Contino@zodiacaerospace.com
Name: Joseph Contino
Organization: AVOX Systems Inc.
Email: joseph.contino@zodiacaerospace.com
Address: 225 Erie Street
City: Lancaster
Zip Code: 14e86
Phone: 716-686-1615
2
- **truncated:** false
- **body characters:** 6267