# Chart Industries, Inc. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 11-0144
- **title:** Chart Industries, Inc. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2012-01-19
- **effective on:** Not available
- **summary:** 11-0144 response to Chart Industries, Inc. concerning 171.22, 172.101, 173.320.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-11-0144.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-11-0144.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-11-0144
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2011/110144.pdf
**body:**

<<<PAGE 1>>>

1200 New Jersey Avenue SE
U.S. Department WashIngton. DC 20590
of Transportation
Pipeline and Hazardous
M.aterials Safety
Administration
JAN 192012
Mr. Marty Beyer
Quality Analyst
Chart Industries lric.
1300 Airport Drive
Ball Ground, GA 30107
Ref. No.: 11-0144
Dear Mr. Beyer:
This responds to your initial July 1,2011 request and subsequent July 13, 2011 email seeking
clarification of the requirements in the International Air Transport Association's (IA TA)
Dangerous Goods Regulations and the Hazardous Materials Regulations (HMR; 49 C.F.R. Parts
171-180). As information, the lATA regulations do not have official standing under the HMR.
The regulations recognized by the HMR and conditionally authorized for use in § 171.22 are the
International Civil Aviation Organization's (ICAO) Technical Instructions. Since the 2011-2012
edition of the ICAO Technical Instructions includes the same Packing Instruction 202, this letter
interprets the ICAO provision. Your questions are paraphrased and answered below.
Q1. Would the requirements in Packing Instruction 202 for open cryogenic receptacles allow the
markings to be engraved or printed on a permanently attached data plate welded to the upper
surface ofthe receptacle?
A 1. Yes. Package Instruction 202 requires the marks to be "permanently affixed, e.g. by
stamping, engraving or etching." Markings on a data plate welded to the upper surface of the
receptacle would be considered permanently affixed.
Q2. Would the requirements in Packing Instruction 202 for open cryogenic receptacles allow the
markings to be on an adhesive label attached to the upper surface ofthe receptacle?
A2. Yes. Package Instruction 202 ofthe ICAO Technical Instructions states that the receptacle
must be "designed, manufactured, tested and equipped in such a way as to withstand all
conditions, including fatigue, to which they will be subjected during their normal use and during
normal conditions oftransport." Further, Package Instruction 202 requires that the marks be
permanently affixed to the receptacle. While this office generally does not recommend the use
ofa label for permanently affixing package markings to a receptacle, provided the label is of a
permanent character and affixed in a permanent manner, it is our opinion that affixing a printed
label is acceptable.

<<<PAGE 2>>>

Q3. Would the requirements in Packing Instruction 202 for open cryogenic receptacles allow the
markings to be engraved on a tag that is attached by a cable or short chain to the upper surface of
the receptacle?
A3. No. It is our opinion that a tag is not affixed to the receptacle.
Q4. May open top cryogenic receptacles with free liquid nitrogen in the bottom be shipped
under Package Instruction 202 as a dry shipper?
A4. No. Section 173.320(a) oftheHMR provides that cryogenic liquids in Dewar flasks
designed and constructed so that the pressure will not exceed 25.3 psig under normal ambient
temperature conditions when transported by rail and motor vehicle are not subject to the HMR
requirements. However, for transportation by aircraft, an offeror must follow all applicable air
transportation requirements. Additionally, when transported by aircraft, a dry shipper may not
contain any unabsorbed liquid.
Q5. When returned empty with some absorbed liquid nitrogen, is the container still considered a
dry shipper?
A5. Yes. A dry shipper, which is a specially designed Dewar flask that uses nitrogen,
refrigerated liquid as a refrigerant, would still be considered a dry shipper if the absorbent
material is saturated with nitrogen, refrigerated liquid, with no free liquid present in the
packaging.
Q6. What is the function of the UN number marking?
A6. The UN number is an identification number assigned to each proper shipping name of a
material designated as a hazardous material in the HMR or a dangerous good in the ICAO
Technical Instructions. A list ofhazardous materials and their identification numbers is located
in the Hazardous Materials Table in § 172.101 ofthe HMR, and in Table 3.1 ofthe ICAO
Technical Instructions.
I hope this answers your inquiry. If you need additional assistance, please contact the Standards
and Rulemaking Division at (202) 366-8553.
Sincerely, ~
t:.r:.
t:tor
Standards and Rulemaking Division

<<<PAGE 3>>>

Drakeford, Carolyn (PHMSA)
From: INFOCNTR (PHMSA)
Sent: Friday, July 01, 2011 1 :32 PM
To: Drakeford, Carolyn (PHMSA)
Cc: DerKinderen, Dirk (PHMSA)
Subject: FW: Internationallnterp Request
Hi Carolyn,
We received the following request for an interpretation ofthe ICAO TI. Dirk Der Kinderen advised that Shane Kelley
should be consulted for this letter.
Thanks,
Victoria
Victoria Lehman
Hazmat Information Center (HMIC)
http://phmsa.dot.gov/hazmat/info-center
(202) 366-1035
From: Beyer/ Marty [mailto:Marty.Beyer@chartindustries.com]
Sent: Friday/ July 01, 2011 11:36 AM
To: INFOCNTR (PHMSA)
Subject: FW: Request for formal letter of interpretation lATA 52nd edition/ Packing Instructions 202 - Identification
marking question
Hello, my name is Marty Beyer and I would like the proper direction to a identification marking question.
I was directed David Brennan of lATA that in the US the Pipeline and Hazardous Materials Safety
Administration (PHMSA) is the agency that enforce the regulations, and that I should confirm what I propose is
acceptable.
I work for Chart Inc. in Ball Ground GA. One of our product lines is Cryopreservation Equipment for
Transport Systems for Biological Materials (Non pressurized open top cryogenic vessels with non oxidizing
refrigerated liquid). After reviewing the responses below I have a couple questions regarding the new 52nd
Edition of the lATA Dangerous Goods Regulations, specifically Packing Instructions 202. We manufacture
Liquid Nitrogen biological receptacles, and I'm particularly concerned about the NEW requirement Packing
Instructions 202 (i) that Open Cryogenic Receptacles must bear the following marks permanently affixed, e.g.
by stamping, engraving or etching (model, manufacturer name & address, serial number, capacity, UN number)
I would like to get an interpretation of what permanently affixed means. We manufacture aluminum units that
are then painted and have a long life adhesive label for identification. The problem lies in the complexities of
stamping or engraving the compound curve surface on the top of our units and would like clarification on
acceptable alternatives.
I would like to have this information so I can direct manufacturing on the correct path.
Will it be acceptable to attach to the upper part of the container as an alternate to stamping, engraving or
etching:
1

<<<PAGE 4>>>

Engraved aluminum data plate welded on the data plate corners to the upper surface of the units.
Engraved aluminum data plate 20 gauge (.030") or thicker with permanent adhesive (min 32 oz
pull/sqin) to the upper surface of the units.
A heavy aluminum tamperprooffoillabel (.010) with permanent adhesive (min 32 oz pull/sqin) to the
upper surface of the units.
A heavy plastic tamperprooflabel (.010) with permanent ink and adhesive (min 32 oz pull/sqin) to the
upper surface of the units.
Engraved aluminum data plate 20 gauge (.030") or thicker lanyard attached (short cable or chain) to
the upper surface of the unit.
The clarification will greatly assist us as all of these alternatives have been discussed but are not known to be
acceptable.
Marty Beyer
Quality Analyst
770-721-7686
-----Original Message----From:
BRENNAN Dave [mailto:brennand@iata.org]
Sent: Friday, July 01, 2011 3:40 AM
To: Beyer, Marty
Cc: Maloy, Neal; KadrlikJ Ben; Thissen, Kevin
Subject: RE: 52nd edition, Packing Instructions 202
Marty,
What you describe for the permanent marking appears to be reasonable. HoweverJ as compliance
with the regulations is enforced by the competent authority, in the US it's the Pipeline and
Hazardous Materials Safety Administration (PHMSA), you should really confirm with PHMSA that
what you propose is acceptable.
PHMSA have a safety information center that provides answers/interpretations on the
regulations. They can be contacted at: Tel: 1 800 467 4922, (202) 366 4488 or email:
infocntr@dot.gov
Regards,
David BRENNAN
Asst. Director Cargo Safety &Standards
Tel: +41-22-770-2947
Fax: +41-22-770-2678
email: brennand@iata.org
International Air Transport Association
33 J Route de l'Aeroport
1215 Geneva 15 Airport
2

<<<PAGE 5>>>

Switzerland
www.iata.org/dangerousgoods
Please consider the environment before printing this email
-----Original Message----From:
Beyer, Marty [mailto:Marty.Beyer@chartindustries.com]
Sent: Thursday, 3e June 2e11 22:13
To: BRENNAN Dave
Cc: Maloy, Neal; Kadrlik, Benj Thissen, Kevin
Subject: FW: 52nd edition, Packing Instructions 2e2
Hi Dave my name is Marty Beyer) and I also work for CAIRE Inc. After reviewing the responses
below I have a couple questions regarding the new 52nd Edition of the lATA Dangerous Goods
Regulations) specifically Packing Instructions 2e2. We manufacture Liquid Nitrogen
receptacles) and I'm particularly concerned about the NEW requirement that Open Cryogenic
Receptacles must bear the following marks permanently affixed) e.g. by stamping) engraving or
etching (model) manufacturer name &address) serial number) capacity) UN number)
I would like to get an interpretation of what permanently affixed means. We manufacture
aluminum units that are then painted and have a long life adhesive label for
identification. The problem lies in engraving the compound curve surface on the top of the
units.
I would like to have this information so I can direct manufacturing on the correct path.
Will it be acceptable to attach to the upper part of the container as an alternate to
stamping, engraving or etching:
Engraved aluminum data plate welded on the data plate corners to the upper surface of the
units.
Engraved aluminum data plate 2e gauge (.e3e") or thicker with permanent adhesive (min 32 oz
pull/sqin) to the upper surface of the units.
A heavy aluminum tamperproof foil label (.e1e) with permanent adhesive (min 32 oz pull /sqin
) to the upper surface of the units.
A heavy plastic tamperproof label (.e1e) with permanent ink and adhesive (min 32 oz pull
/sqin ) to the upper surface of the units.
Engraved aluminum data plate 2e gauge (.e3e") or thicker lanyard attached (short cable or
chain) to the upper surface of the unit.
The clarification will greatly assist us as all of these alternatives have been discussed but
are not known to be acceptable.
Marty Beyer
Quality Analyst
77e-721-7686
marty.beyer@chart-ind.com
ASQ CQE) CQA, CQT
-----Original Message--- ­ From: BRENNAN Dave [mailto:brennand@iata.org]
3

<<<PAGE 6>>>

Sent: Wednesday, February 23, 2011 2:19 PM
To: Kadrlik, Ben
Subject: RE: 52nd edition, Packing Instructions 202
Ben J
My apologies I should have gotten back to you on this. I raised this at the UN Subcommittee
in December and there was agreement that existing cryogenic receptacles should be
grandfathered and the marking would only apply to new receptacles manufactured after 1
January 2012. ICAD has adopted this and it will also be brought into the other regulations.
Attached is a copy of the addendum to the 52nd edition of the DGR that reflects this in PI
202.
Regards J
David
-----Driginal Message----From:
Kadrlik, Ben [mailto:Ben.Kadrlik@CHART-IND.com]
Sent: Wednesday, 23 February 2011 13:51
To: BRENNAN Dave
Subject: RE: 52nd edition, Packing Instructions 202
David-
Hi this is Ben Kadrlik, we spoke back in December regarding the new 52nd edition. I was
wondering if you had heard anything further from the last time we spoke. Thank you, Ben K.
-----Driginal Message----From:
BRENNAN Dave [mailto:brennand@iata.org]
Sent: Tuesday, December 07, 2010 4:34 AM
To: Kadrlik, Ben
Subject: RE: 52nd edition, Packing Instructions 202
Ben,
The issue of the marking of open cryogenic receptacles has just been discussed by the UN
Subcommittee. What was agreed was:
1. The new marking on open cryogenic receptacles will not come into effect until 1 January
2012. This will be addressed in an addendum to the 52nd edition of the DGRj 2. The size of
the marking should be as required for cylinders as set out in DGR 6.4.2.7.1j and 3. Existing
open cryogenic receptacles do no not have to be marked.
Regards,
David
From: Kadrlik, Ben [Ben.Kadrlik@CHART-IND.com]
Sent: Wednesday, December 01 J 2010 3:20 PM
To: BRENNAN Dave
Subject: 52nd edition, Packing Instructions 202
David 8rennandHi
my name is Ben Kadrlik, and I work for CAIRE Inc., and I have a couple questions regarding
the new 52nd Edition of the lATA Dangerous Goods Regulations, specifically Packing
4

<<<PAGE 7>>>

Instructions 202. We manufacture Liquid Nitrogen receptacles, and I'm particularly concerned
about the NEW requirement that Open Cryogenic Receptacles must bear the following marks
permanently affixed, e.g. by stamping, engraving or etching (model, manufacturer
name&address, serial number, capacity, UN number) ...
My question(s) are the following:
* Does this affect units already in the field i.e. will be need to develop a
service plan to take units in and alter them with this engraving/stamping, or will they get
to be "grandfathered" in?
* Does size & location of the engraving/stamping matter? Can we place this
information on the outer bottom of the unit (as not to disrupt our paint process)?
* Since this is lATA and not DOT, it seems to be an international change only, does
that mean we are currently okay in the US? Are there plans to harmonize with DOT?
I know this is a lot, but any help would be greatly appreciated!! I believe one of my
colleagues, Kevin Thissen, may have already contacted you.
Thank you again, Ben K.
Ben Kadrlik
Quality Engineer
CAIRE INC.
2200 Airport Industrial Drive
Suite S00, Ball Ground, GA 30107
Office: 770.721.7730
Mobile: 678.469.6471
Fax: 770.721.7700
This message contains confidential information and is intended only for the individual named.
If you are not the named addressee you should not disseminate, distribute or copy this email.
Please notify the sender immediately bye-mail if you have received this e-mail by
mistake and delete this e-mail from your system.
E-mail transmission cannot be guaranteed to be secure or error-free as information could be
intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The
sender therefore does not accept liability for any errors or omissions in the contents of
this message which arise as a result of e-mail transmission.
This message contains confidential information and is intended only for the individual named.
If you are not the named addressee you should not disseminate, distribute or copy this email.
Please notify the sender immediately bye-mail if you have received this e-mail by
mistake and delete this e-mail from your system.
E-mail transmission cannot be guaranteed to be secure or error-free as information could be
intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The
sender therefore does not accept liability for any errors or omissions in the contents of
this message which arise as a result of e-mail transmission.
This message contains confidential information and is intended only for the individual named.
If you are not the named addressee you should not disseminate, distribute or copy this email.
Please notify the sender immediately bye-mail if you have received this e-mail by
mistake and delete this e-mail from your system.
5

<<<PAGE 8>>>

E-mail transmission cannot be guaranteed to be secure or error-free as information could be
interceptedJ corrupted) lost, destroyed, arrive late or incomplete, or contain viruses. The
sender therefore does not accept liability for any errors or omissions in the contents of
this message which arise as a result of e-mail transmission.
6

<<<PAGE 9>>>

Winter, lisa (PHMSA)
From: Beyer, Marty [Marty.Beyer@chartindustries.com]
Sent: Wednesday, July 13, 2011 8:21 AM
To: Winter. Usa (PHMSA)
Subject: Chart - Request For Formal Letter of Interpretation
Attachments: MVE Doble Series - catalog page. pdf; MVE Cryro Shipper QWick Series - catalog page.pdf;
MVE Doble QWick Series - catalog page.pdf
Lisa I thank you for responding back. I am relatively new to this product line and process and I am trying to assist in
getting information and interpretations.
We are in the process of getting pictures of the different ways to identify the open cryogenic receptacles. Since we were
only discussing these other options it will take us awhile to create and get the pictures for you to review. I have attached
catalog pages as a representation of the 3 model lines that will probably be affected by the changes on Packaging
Instruction 202
In the meantime I have a few other questions for clarification if you could assist us in clarification it would be greatly
appreCiated.
On our non pressurized open top cryogenic receptacles the MVE Doble Series & MVE Doble QWick Series are mostly
used as dry shippers by our customers. The customers add liquid nitrogen into the unit and is absorbed in a
hydrophobic compound so the liquid nitrogen is not in a free state. (Dry shipper). My question is some of our customers
"top off lithe units with a little free liquid nitrogen in the bottom of the unit to extend the storage time when shipping.
Will this still be acceptable under Packaging Instruction 202 as a dry shipper? Or would the unit change category as a
Dry shipper to a liquid shipper. Or is there a limit- say only max 2/1 of free liquid in the bottom is acceptable?
The next question is when the units need to be returned empty. It may still be cold with some absorbed liquid nitrogen
or warm. Would this returning unit be considered a dry shipper or something else like standard freight?
This next question came up in discussion and I am a little confused as I have not seen it stated or have missed it in the
standard.
The question is of the function of the UN number? Is this related to the new labeling or registration # ? Or is it
something totally not related.
Please assist me and clarify.
I look forward to your reply as we looking forward to implement changes to meet the new requirements.
Thank you
Marty Beyer
Quality Analyst
770-721-7686
From: lisa.winter@dot.gov [mailto:lisa.winter@dot.gov]
Sent: Thursday, July 07,201110:15 AM
To: Beyer, Marty
Subject: Request For Formal Letter of Interpretation
1

<<<PAGE 10>>>

Dear Mr. Beyer:
I have been assigned your request for interpretation of ICAO Packing Instruction 202 pertaining to Paragraph 9 and the
meaning of "permanently affixed." You provide five scenarios and ask if they meet the requirements of Packing
Instruction 202. For us to better determine if the options you describe meet the specifications of Packing Instruction
202, would it be possible for you to provide photographs of the involved open top cryogenic vessels with the markings
as provided in each scenario?
Thank you in advance for your help.
Sincerely,
Lisa (Winter) O'Donnell
Transportation Regulations Specialist
Pipeline and Hazardous Materials Safety Administration
United States Department of Transportation
202.366.6415
http://www.phmsa.dot.gov/hazmat
2

<<<PAGE 11>>>

The Doble QWick Series utilizes an absorbent wicking material that charges with liquid nitrogen in fewer than two
hours. providing the capacity for same-day vapor shipping. A unique absorbent layer in the base of the storage
tanks enables them to be charged with nitrogen and employed as dry shippers with hold times of up to 30 days.
Once at the final destination, the tanks can be filled with liquid and used for long term storage, therefore avoiding
the need tor return shipments. Equipped with the same capacity and dimensions as the comparable Doble Series,
Features Include:
•CHARGES IN LESS THAN TWO HOURS
• Liquid and vapor storage options
• Low liquid nitrogen consumption
• Convenient lightweight package
Accessories:
r
t,
CryoGloves Vapor Insert Liquid Level Straws Roller Base
Measuring Stick
20 Cryopreservation Equipment Catalog

<<<PAGE 12>>>

~ .' ".',' ,
;:'," ~1, ;',', \
"~ ~,:', (
MVE CryoShipper QWick Series utilizes an absorbent wicklng malerial that charges with liquid nitrogen in fewer " ,
than two hours, providing the capacity for same-day vapor shipping. Manufactured from durable, lightweight
aluminum, they employ a hydrophobic compound which absorbs the liquid nitrogen to ensure dry, spill-free
shipping.
Protective shipping cartons are available. These containers may be used to ship your samples with a "nonhazardous"
classi'fication throughout the world, thus reducing shipping costs and helping to assure sample viability.
Equipped with the same capacity and dimensions as the comparable MVE Vapor Shipper Series.
Features Include:
• CHARGES IN LESS THAN TWO HOURS
• Protective shipping carton to ensure upright shipping
• Low liquid nitrogen consumption
• Convenient lightweight packages
Accessories:
r
CryoGloves Vapor Inserts CryoBlocks Square Racks Datalogger Plastic Boxes
18 Cryopreservation Equipment Catalog

<<<PAGE 13>>>

The Doble QWick Series utilizes an absorbent wicking material that charges with liquid nitrogen in fewer than two
hours, providing the capacity for same-day vapor shipping. A unique absorbent layer in the base of the storage
tanks enables them to be charged with nitrogen and employed as dry shippers with hold times of up to 30 days.
Once at the final destination, the tanks can be filled with liquid and used for long term storage, therefore avoiding
the need for return shipments. Equipped with the same capacity and dimensions as the comparable Doble Series.
Features Include:
• CHARGES IN LESS THAN TWO HOURS
• Liquid and vapor storage options
• Low liquid nitrogen consumption
• Convenient lightweight package
Accessories:
r
CryoGloves Vapor Insert Straws Roller Base
Liquid Level
Measuring Stick
20 Cryopreservation Equipment Catalog
i---,
i
1
1.

<<<PAGE 14>>>

Sample label layout- Label and
markings will be of material that is LN2
compatible with permanent adhesive.
Dewar's are aluminum with LN2
compatible paint that very seldom needs
repainting for the life of the unit. Label
size 1.5" x 3.5" this is max size to use
to be near top of neck.

<<<PAGE 15>>>

Sample label layout- Label and
markings will be of material that is LN2
compatible with permanent adhesive.
Dewar's are aluminum with LN2
compatible paint that very seldom needs
repainting for the life of the unit. Label
size is 2" x 4"
- **truncated:** false
- **body characters:** 22490