# Broward Fire Equipment and Service Inc. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 12-0075
- **title:** Broward Fire Equipment and Service Inc. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2012-03-09
- **effective on:** Not available
- **summary:** 12-0075 response to Broward Fire Equipment and Service Inc. concerning 173.309, 173.6.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-12-0075.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-12-0075.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-12-0075
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2012/120075.pdf
**body:**

<<<PAGE 1>>>

U.S. Department Ni1shlnglon. DC' 20590
1200 New Jersev Avenue SE
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
MAR 0 9 2012
John A. Gioseffi
President
Broward Fire Equipment and Service (nc.
1 0 1 SW 6th Street
Fort Lauderdale, FL 33301
Ret: No. 12-0075
Dear Mr. Gioseffi:
This is in response to your email and conversation with a member ofPHMSA's field operations
staff concerning the requirements tor fire extinguishers shipped by motor vehicle in contormance
with § 173.309 ofthe Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180).
Fire extinguishers charged with a limited quantity ofcompressed gas are excepted from labeling
and the specification packaging requirements ifthe cylinder is packaged and offered for
transportation in accordance with § 173.309(a) through § 173.309(a)(3)(iv). One of those
conditions requires the fire extinguisher to be shipped as an inner packaging.
You asked several questions regarding the applicability of the limited quantity exception to
unpack aged fire extinguishers and the selection ofa proper shipping name for a fire extinguisher
that does not meet the limited quantity provisions. We have paraphrased and answered these
questions below:
Q 1. Does the practice of placing many fire extinguishers into a large fiberboard carton, a cage or
a rack meet the condition of § t 73.309(a) that requires fire extinguishers to be shipped as an
inner packaging?
A 1. The answer is yes. In the examples described above, the fire extinguisher is the inner
packaging and the cage, rack or large tiberboard carton is the outer packaging. The outer'
packaging must be marked accordingly if intended for transportation.
Q2. Does strapping fire extinguishers into a vehicle meet the condition of § I 73.309(a) that fire
extinguishers be shipped as an inner packaging?
A2. No, however a person may transport by motor vehicle, fire extinguishers that are secured
against shifting and protected against damage without an outer packaging in conformance the

<<<PAGE 2>>>

provisions § 173.6 provided the fire extinguishers meet the definition of material oftrade in §
171.8. .
Q3. Ifa fire extinguisher is not shipped as an inner package of a combination package, and the
aggregate gross weight limit for the materials of trade exception is exceeded, how should these
fire extinguishers be marked?
A3. Fire extinguishers that exceed the aggregate gross weight limits authorized by the materials
of trade exception must be marked with the proper shipping name "Fire extinguishers" and the
identitication number II UN 1 044" and each cylinder must display the Division 2.2 label.
I hope this information is helpful. If you have further questions, please contact this office.
Sincerely,
~~~~
r~~ar1es E. Betts
~ctor
Standards and Rulemaking Division
cc: Norb Makowka, National Association ofFire Equipment Distributors

<<<PAGE 3>>>

L~Ctrq
Here is Norb's email address NorbM@nafed.org.
~ 113.jo'f.
Thanks for your assistance with this. ~i tf'e.. f::,)(.+-," Y\~ Lt rsher;
Rob I Z. - 0016
From: John Giosefft [mailto:jgioseffi@browardfire.com]
Sent: Thursday, March 01, 2012 2:07 PM
To: 'Norb Makowka'
Cc: Streck, Stuart (PHMSA); DiGiacomandrea, Robert (PHMSA)
Subject: DOT News
To: Norb Makowka
Executive Director - T echnicaJ
National Association of Fire Equipment Distributors (NAFEO)
122 South Michigan Ave., Suite 1040
Chicago,lL 60603
(312) 461-9600
Norb,
This past weekend, FFEDA hosted a training seminar in Ocala where we were fortunate to have two representatives from
the U.S. Department of Transportation conduct a very interesting and informative presentation. They were Stu Streck,
HAZMAT Safety Assistance Team, and Robert (Rob) Oigiacomandrea, Investigator. Both are out of the Southem Region
Field Operations Office, located in Atlanta.
I can not adequately reflect how informative the presentation was. Both DOT representatives were very professional and
responsive to our questions and concems. They told the fire equipment distributors in attendance that some of the most
common violations of 49 CFR that they see in the field during fire equipment facility inspections are using the correct
hydrotest label format (NAFED has the solution to that problem) and fire extinguishers labeled as UN1066 "Nitrogen"
instead of UN1044 "Fire Extinguisher." We requested whatever documentation they could share with the industry and Stu
Streck followed-up with me earlier today to let me know that they currently have only an internal memorandum and that
they are working on a document for general distribution that clarifies the UN1044 issue.
Stu Streck also informed me of a multi-modal seminar they have scheduled for the Atlanta area on June 19 - 20, where
they are going to use part (second half) of the same information they presented for FFEOA in Ocala. I'm sure it will
include information critical for NAFED members. I have cc'd both Stu Streck and Robert Digiacomandrea on this email so
you have their email addresses. The phone for Stu Streck in the Atlanta DOT office is (404) 832-1145. I'm sure they
would welcome and encourage NAFEO's attendance at their seminar.
Let me know if I can be of any assistance in "getting the word out."
John
John A. Gioseffl
President
Broward Fire Equipment and Service Inc.
101 SW 6th Street
Fort Lauderdale, FL 33301
Phone: (954) 467-6625
Fax: (954) 467-6640
2
- **truncated:** false
- **body characters:** 5387