# Western International Gas & Cylinders — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 13-0075
- **title:** Western International Gas & Cylinders — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2013-05-15
- **effective on:** Not available
- **summary:** 13-0075 response to Western International Gas & Cylinders concerning 173.301b.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-13-0075.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-13-0075.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-13-0075
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2013/130075.pdf
**body:**

<<<PAGE 1>>>

U.S. Department of Transportation
Pipeline and Hazardous Materials
Safety Administration
1 200 New Jersey Ave, SE
Washington, D.C. 20590
MAY 1 5 2013
Dr. Wesley D. Scott
Western International Gas & Cylinders
P.O. Box 668, 7173 Highway 159 East
Bellville, Texas 77418
RefNo.: 13-0075
Dear Dr. Scott:
This is a response to your April 4, 2013 email requesting clarification of the Hazardous Materials
Regulations (HMR; 49 CFR Parts 1 00-185) with regard to UN pressure receptacles. Specifically,
you request clarification of the "H" marking required by § 173.301 b(f) and the filling of steel UN
pressure receptacles.
In your email you note that § 173.301 b(f) requires that a steel UN pressure receptacle bearing an
"H'' mark be used for hydrogen bearing gases. You indicate that based on information provided at
Compressed Gas Association (CGA) meetings and discussions with Mark Toughiry ofPHMSA's
Engineering and Research Division, the intent of this section is not to limit pressure receptacles
bearing an "H" marking exclusively to hydrogen bearing or embrittling gas service. You request
confirmation that pressure receptacles bearing the "H" mark are suitable for use for all gases in
which a steel cylinder is specified as acceptable.
It is the opinion of this office that pressure receptacles bearing the "H" mark may be filled with
hydrogen bearing gases, embrittling gases, or any other gases for which a steel pressure receptacle
is indicated as appropriate. For hydrogen bearing and embrittling gases for which Special
Provision N89 is listed in column 7 of the Hazardous Materials Table (HMT) in § 1 72.101 and
when a steel UN pressure receptacle is used, that pressure receptacle must bear the "H" mark.
I hope this information is helpful. If you have any more questions, please do not hesitate to
contact this office.
Sincerely,
Robert Benedict
Chief, Standards Development
Standards and Rulemaking Division
-----------
-~-··--·-~-

<<<PAGE 2>>>

.Qrakeford, Carolyn (PHMSA)
From:
Sent:
To:
Subject:
INFOCNTR (PHMSA)
Tuesday, April 09, 2013 2:18PM
Drakeford, Carolyn (PHMSA)
FW: Request for Interpretation 49CFR173.301b
Hi Carolyn,
This caller would like their letter submitted a letter of interpretation.
Thanks,
Victoria
From: Wesley Scott [mailto:wesleyscott@westernintl.com]
Sent: Thursday, April 041 2013 3:25 PM
To: INFOCNTR (PHMSA)
Cc: Toughiryr Mark (PHMSA)
Subject: Request for Interpretation 49CFR173.301b
Western International Gas & Cylinders, Inc. requests a formal interpretation of 49CFR173.301b, specifically sub-paragraph
(f).
(f) Hydrogen bearing gases. A steel UN pressure receptacle bearing an "H" mark must be used for hydrogen bearing gases
or other embrittling gases that have the potential of causing hydrogen embrittlement .
.
'
Western International Gas & Cylinders, Inc. is a distributor of UN/ISO cylinders manufactured to ISO specification 9809-
1. One of our customers has expressed concern that "H" marked cylinders can only be used for hydrogen
bearing/embrittling gases based on the phrase "must be used for" in 49CFR173.301b(f).
It is Western's understanding based on information received at Compressed Gas Association (CGA) meetings and
discussion with Mark Toughiry (US Department of Transportation, Pipeline and Hazardous Materials Safety
Administration, Engineering and Research) that the intent of 49CFR173.301b(f) is to require hydrogen bearing/embrittling
gases be limited to cylinders with the "H" mark. However, steel cylinders bearing an "H" mark are suitable for use for all
gases where a steel cylinder is specified as acceptable, excluding those gases that require a high grade stainless steel.
Confusion over the meaning of the "H" mark will adversely affect the acceptance of UN cylinders in the US market. We
therefore request an official confirmation that cylinders with an "H" mark are not limited to hydrogen bearing/embrittling
gas service.
Wesley D. Scott, PhD, PE
Senior Review Technologist (SRT)
Western International Gas & Cylinders, Inc.
P.O. Box 668, 7173 Highway 159 East
Bellville, Texas 77418
T:979.413.2186 F:979.413.2386
E-mail: wesleyscott@westernintl.com
www.westernintl.com
NOTICE BY WESTERN INTERNATIONAL GAS & CYLINDERS, INC. This electronic message is sent for the sole purpose of
delivery to an intended recipient. Its contents are confidential and may be legally privileged. If you have received this
1

<<<PAGE 3>>>

message in error, any use, dissemination hereof is strictly prohibited, and you should immediately delete the message and
any attachments, and notify me of your receipt of the message.
2