# 5N Plus Wisconsin, Inc. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 14-0136
- **title:** 5N Plus Wisconsin, Inc. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2014-10-24
- **effective on:** Not available
- **summary:** 14-0136 response to 5N Plus Wisconsin, Inc. concerning 173.28, 178.503.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-14-0136.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-14-0136.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-14-0136
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2014/140136.pdf
**body:**

<<<PAGE 1>>>

of Transportation
U.S. Department
1200 New Jersey Avenue, SE
Washington, D.C. 20590
Materials Safety
Pipeline and Hazardous
Administration
OCT 2 4 2014
Ms. Laura Buholca
Plant Manager
SN Plus Wisconsin, Inc.
6474 Blanchar's Crossing
Windsor, WI 53598
Ref. No. 14-0136
Dear Ms. Buholca:
This responds to your July 11, 2014 request for clarification on the reuse of metal and plastic
drums under the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180).
Specifically, you ask if you need a wall thickness marking on the UN 1H2 drum (used as the
outer packaging of a combination packaging) used to transport "UN3260, Corrosive solids,
acidic, inorganic, n.o.s. (gallium trichloride), 8, PGII," under the reuse provisions in
§ 173.28(b)(4).
In a conversation with a member of our staff in the Hazardous Materials Information Center
(HMIC), you asked if the wall thickness marking is required to reuse a UN 1H2 plastic drum.
The HMIC informed you that under § 173.28(b)(4) the wall thickness marking is required to
be marked on the drum if it is the outer drum of a composite packaging or a single packaging.
It is your understanding then that combination packaging is not required to be marked with
the wall thickness under the reuse provisions in § 173.28(b)(4).
Your understanding is correct. In accordance with §§ 173.28(b)(4) and 178.503(a)(9), plastic
drums used as single packagings or outer packaging of composite packagings and intended to
e reused must be marked with the minimum wall thickness of the packaging material. Thus
plastic drum of a combination packaging is not required to be marked with the wal
thickness. The packaging scenario you illustrate is considered a combination packaging by
definition and is not required to be marked with the wall thickness under the reuse provisions
in § 173.28(b)(4).
I hope this answers your inquiry. If you need additional assistance, please contact this Office
at (202) 366-8553.
Acting Chief, Standards Development Branch
Standards and Rulemaking Division

<<<PAGE 2>>>

Boothe
178.503
173,29
Goodall, Shante CTR (PHMSA)
From:
INFOCNTR (PHMSA)
Markings f
Packings
Sent:
Monday, July 14, 2014 4:07 PM
To:
Hazmat Interps
14-0136
Subject:
FW: letter of interpretation
Hi Alice and Shante,
We received this request for a letter of interpretation. Thanks.
-Adam
From: Laura Buholca [mailto:Laura.Buholca@5nplus.com]
Sent: Friday, July 11, 2014 3:10 PM
To: PHMSA HM InfoCenter
Subject: letter of interpretation
Good afternoon,
I spoke to Adam earlier today and received a very good interpretation on the topic; however, in order to satisfy my
customers request, I would like to receive letter of interpretation, because our goal is to be in complete compliance and
transport our haz mat product safely.
5N PLUS
1 Fastening ausche»

<<<PAGE 3>>>

Material we are shipping:
UN3260
Corrosive Solids, Acidic,
Inorganic, N.O.S. (Gallium Trichloride)
CLASS 8
PG IT
Here is the packaging what we are using:
- Material (7.5 kgs) is being placed in glass ampule; seal tape is applied; ampule is placed in fibreboard drum with foam
ushioning, it is packaged tight filling all space between bottle and fibreboard drum (picture on lower left); fibreboar
rum is sealed with tape and placed in plastic bag and bad is sealed; all that is inserted into blue outer drum; foan
cushioning fills space between fibreboard drum and blue drum; Blue drum is sealed;
The question is regards outer drum; drum is UN certified, but has no wall thickness identified on the drum.
Here is the specifications for the drum:
IH2 X225/S/12
DABAN 9624
My question is - do we need a wall thickness, any additional certification or anything else possible that I've overlooked
regards this outer drum that would limit us from re-using this drum for future shipments.
Please do not hesitate to contact me if there is any additional information needed.
2 12f
Many thanks
Laura
Laura Buholca | Plant Manager
5N Plus Wisconsin Inc.
6474 Blanchar's Crossing, Windsor, WI 53598
170
2
T. 608-846-1357x8004
F. 608-846-1394
c. 608-512-9319
Confidentiality: This message is intended solely for the addressee or the entity to which it is addressed and may contain information which is privileged
eproduction of this document is strictly forbidder
confidential or protected from disclosure. If you are not the intended recipient, please notify us immediately and destroy this document. Any use, copying o
2
- **truncated:** false
- **body characters:** 4424