# Green Environmental Consulting — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 15-0130
- **title:** Green Environmental Consulting — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2015-10-02
- **effective on:** Not available
- **summary:** 15-0130 response to Green Environmental Consulting concerning 172.101, 173.120, 173.150, 173.22.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-15-0130.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-15-0130.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-15-0130
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2015/150130.pdf
**body:**

<<<PAGE 1>>>

of Transportation
U.S. Department
1200 New Jersey Avenue, SE
Washington, D.C. 20590
Materials Safety
Pipeline and Hazardous
Administration
OCT 0 2 2015
Ms. Peggy Haase
2822 Grants River Circle
Green Environmental Consulting
Sugar Land, TX 77479
Ref. No. 15-0130
Dear Ms. Haase:
This responds to your June 23, 2015 request for clarification pertaining to combustible liquid
material under the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180).
Specifically, you ask whether "UN1223, Kerosene" with a flash point of 150 °F must be
classified as a "Combustible liquid," or whether the more stringent flammable liquid class
may be used
Based on the information you provided, the material must be classified as a Combustible
liquid. Flammable and combustible liquids must be classed and described according to
defining criteria in § 173.120 and the shipper's knowledge of the material (See § 173.22).
Therefore, if the material meets the definition of a combustible liquid in § 173.120, it must
be classed and described as such. If the flash point of your material is greater than 140 °F
but less than 200 °F, and the material does not meet the definition of any other hazard class,
it must be classed as a combustible liquid for domestic transportation. Furthermore,
§ 172.101(d)(4) requires that each reference to a Class 3 material is modified to read
"Combustible liquid" when that material is reclassified in accordance with
§ 173.150(e) or (f) or has a flash point above 60 °C (140 °F) but below 93 °C (200 °F).
I hope this satisfies your request.
Sincerely,
TAlenn Fister
-
T. Glenn Foster
Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division

<<<PAGE 2>>>

Lehman:
173.120
Goodall, Shante CTR (PHMSA)
class 3 firation
From:
Geller, Shelby CTR (PHMSA)
15 - 0130
Sent:
Wednesday, June 24, 2015 4:32 PM
To:
Hazmat Interps
Subject:
FW: Interpretation Request
Hi Shante and Alice,
Please see the request below for a formal letter of interpretation. Ms Haase spoke with both Adam Lucas and Jordan
Rivera. Below is her mailing address:
2822 Grants River Circle
Sugar Land, TX 77479
Thanks,
Shelby
From: phaase [mailto:phaase@green-envi.com]
Sent: Tuesday, June 23, 2015 3:41 PM
To: PHMSA HM InfoCenter
Subject: Interpretation Request
I understand that if a Kerosene product has a flash point of 150 F, UN 1223 should still be used, but
the hazard class can be changed from "3" to "Combustible". My question is whether or not it is
acceptable to leave the hazard class as "3".
Thank you,
Peggy Haase
GREEN Environmental Consulting
832-515-3452
- **truncated:** false
- **body characters:** 2591