# Infineum USA L.P. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 15-0247
- **title:** Infineum USA L.P. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2016-03-07
- **effective on:** Not available
- **summary:** 15-0247 response to Infineum USA L.P. concerning 173.24.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-15-0247.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-15-0247.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-15-0247
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2016/150247.pdf
**body:**

<<<PAGE 1>>>

of Transportation
U.S. Department
Washington, D.C. 20590
1200 New Jersey Avenue, SE
Pipeline and Hazardous
Materials Safety
Administration
APR 0 4 2016
David B. Bower, Ph.D.
Product Stewardship Advisor, Americas
Infineum USA L.P.
1900 East Linden Avenue
P.O. Box 735
Linden, NJ 07036
Reference No. 15-0247
Dear Mr. Bower:
This is in response to your December 16, 2015 letter requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to testing. Specifically, you
ask if the tests your company performed on high-density polyethylene that are fluorinated at
several levels of barrier protection for compatibility with Class 3 (flammable) liquids, comply
with the "Procedure for Testing Chemical Compatibility and Rate of Permeation in Plastic
Packaging and Receptacles" as prescribed in 49 CFR Part 173, Appendix B of the HMR.
The answer is no. Section 2 of 49 CFR Part 173, Appendix B, prescribes only three test
methods for determining compatibility and rate of permeation in plastic packagings and
receptacles. Test Method 2 requires 28 days of testing at a temperature no lower than 50 °C
(122 °F). Your report states that its tests were conducted at 50 °C for 112 days. While the
HMR is clear that the temperature used for this test method can be higher, the length of time
permitted for the test must be 28 days. If your company would like to vary from these test
methods, it must apply for an approval in conformance with the requirements prescribed in
§ 173.24(e)(3)(iii). This section states that if alternative procedures or rates of permeation are
requested they must yield a level of safety equivalent to or greater than that prescribed in
§ 173.24(e)(3)(ii), and must be specifically approved by the Associate Administrator. To
apply for this approval, you must submit an approval application to the Associate
Administrator for Hazardous Materials Safety in conformance with the requirements
prescribed in 49 CFR Part 107, Subpart H.
I hope this satisfies your request.
Sincerely,
T. Glenn Foster
Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division

<<<PAGE 2>>>

Edmonson
118.403k)iii)
Goodall, Shante CTR (PHMSA)
Doptertin
From:
Geller, Shelby CTR (PHMSA)
15-0247
Sent:
Wednesday, December 16, 2015 4:08 PM
To:
Hazmat Interps
Subject:
FW: Request for interpretation 49 CFR 173 Appendix B
Dear Shante and Alice,
Forwarded is a request for a formal letter of interpretation.
Thanks,
Shelby
To: PHMSA HM InfoCenter
Subject: Request for interpretation 49 CFR 173 Appendix B
You have received * fise
Usa the secure linke t:elow to download
Dear Sir or Madam:
Infineum USA L.P. respectfully requests an interpretation as described in the attached letter. If you have any questions,
please contact me.
Thank you in advance and best regards,
David Bower
David B. Bower, Ph.D.
Product Stewardship Advisor, Americas
Product Stewardship and Regulatory Compliance
INFINEUM USA L.P.
1900 East Linden Avenue, P.O. Box 735
Linden, NJ 07036 USA
Phone +1.908.474.2634
Fax +1.908.474.3025
e-mail david.bower@infineum.com
This note may contain Infineum confidential information. If you are an unintended recipient: (i) place no reliance on the
information contained herein; (il) do not disclose, distribute, or duplicate any information from this note; and (il) please
contact the author. Thank you.
1

<<<PAGE 3>>>

Downiced Flles
Available until: 14 December 2020
Download File: 181264 DOT Interpretation MOPS compedblit
29.96 KBytes,
Secred byaccaffeny
2

<<<PAGE 4>>>

Infineum USA L.P
Product Stewardship and Regulatory Compliance
David B. Bower, Ph.D.
Linden, NJ 07036-1111
1900 East Linden Avenue
Product Stewardship Advisor, Americas
phone +1.908.474.2634
e-mail david.bower@infineum.com
fax +1.908.474.3025
Infineum
14 December 2015
United States Department of Transportation
Attention: PHH-10
PHMSA Office of Hazardous Materials Standards
East Building
1200 New Jersey Avenue South East
Washington, DC 20590-0001
Dear Sir or Madam:
Infineum USA L.P. respectfully asks the Department for its interpretation on the suitability of materials
compatibility tests we have conducted.
49 CFR 173, Appendix B specifies the "Procedure for Testing Chemical Compatibility and Rate of Permeation
in Plastic Packaging and Receptacles" used to transport liquid hazardous materials. Infineum has tested high-
density polyethylene (HDPE) fluorinated at several levels of barrier protection for compatibility with Class 3
flammable liquids. Solvent permeation and drop tests were conducted on small containers made of the same
resin, additives and wall-thickness, by the same process as the full-size 330 gallon tote containers we plan to
use as permitted under Paragraph 4. Strength & hardness were tested using coupons made of the same
materials as the small containers. However, studies were conducted by ageing samples at 50 °C for 112 days
instead of the 28 days as specified in Paragraph 2(b). The test complied with all other requirements of
Appendix B, including the number of containers, measurement of permeation rate and tensile
strength/hardness, and drop testing according to 49 CFR 178.603(e)(iii) for Packing Group Ill materials.
All test containers made of untreated HDPE as well as all fluorinated samples passed the drop test. Solvent
permeation meeting DOT requirements were achieved at the AL (automotive level) of fluorination barrier
treatment. A report from the test laboratory is available if needed.
Infineum contacted the PHMSA call center and was informed verbally that these 112-day test data would be
accepted by the Department. We would appreciate it if you could review the information provided and
confirm this opinion in writing. If you have any questions or need more information, please contact me.
Sincerely,
David B. Bower, Ph.D.
Product Stewardship Advisor, Americas
- **truncated:** false
- **body characters:** 5879