# The Dow Chemical Company — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 16-0063
- **title:** The Dow Chemical Company — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2016-08-02
- **effective on:** Not available
- **summary:** 16-0063 response to The Dow Chemical Company concerning 178.274, 180.605.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-16-0063.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-16-0063.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-16-0063
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2016/160063.pdf
**body:**

<<<PAGE 1>>>

of Transportation
U.S. Department
1200 New Jersey Avenue, SE
Pipeline and Hazardous
Washington, D.C. 20590
Administration
Materials Safety
AUG 0 2 2016
Mr. John Heater
Transportation Safety and Security Specialist
The Dow Chemical Company
100 Independence Mall West
Philadelphia, PA 19106
Reference No. 16-0063
Dear Mr. Heater:
This letter is in response to your April 7, 2016, email requesting clarification of the
Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to requirements
for the periodic testing, inspection, and repair of portable tanks. Specifically, you ask
whether a United Nations (UN) portable tank may be tested with an inert gas, such as .
nitrogen, for the leakage test prescribed in § 180.605(h).
The answer is yes. For the purposes of design and construction of UN portable tanks under
subpart H of part 178 of the HMR, the definition of leakage test in § 178.274(a)(3) means a
test using gas to subject the shell and its service equipment to an internal pressure. Thus, an
inert gas, such as nitrogen, may be used as a test medium for tests conducted as required by
§ 180.605(h).
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
T. Glenn Foster
Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division

<<<PAGE 2>>>

Stevens
178.274
Goodali, Shante CTR (PHMSA)
specifecation tor Un Potae Tak
From:
110 - 0062
Sent:
Geller, Shelby CTR (PHMSA)
To:
Hazmat Interps
Friday, April 08, 2016 9:22 AM
Subject:
FW: Interpretation Letter Request - Dow Chemical
Attachments:
Dow Interpretation Letter Request.pdf
Dear Shante and Alice,
Forwarded is a request for a formal letter of interpretation.
Thanks,
Shelby
From: Heater, John L (J) [mailto:jheater@dow.com]
To: PHMSA HM InfoCenter
Sent: Thursday, April 07, 2016 3:44 PM
Cc: Casillas, Victor (PHMSA)
Subject: Interpretation Letter Request - Dow Chemical
The Dow Chemical Company respectfully submits the attached request for an interpretation letter. Your prompt
processing is necessary and would be greatly appreciated.
Please contact me with any questions or need for additional information.
Sincerely,
John Heater
Transportation Safety and Security Specialist
The Dow Chemical Company
100 Independence Mall West
Philadelphia, PA 19106
Phone: (215) 592-3157
Email: iheater@dow.com

<<<PAGE 3>>>

The Dow Chemical Company
Midland, MI 48674
U.S.A.
April 7, 2016
Via Email
U.S. DOT
PHMSA Office of Hazardous Materials Standards
Attn: PHH-10
East Building
1200 New Jersey Avenue, SE.
Washington, DC 20590-0001
phmsa.hm-infocenter@doi.gov
Subject: Interpretation Letter Request
The Dow Chemical Company ("Dow") respectfully submits this request for an interpretation letter.
• Dow's request is with regard to the intermediate 2.5 year periodic leakage test on UN portable tanks,
specifically the required test medium in the Hazardous Materials Regulations ("HMR"). In
reviewing both the HMR and International Maritime Dangerous Goods ("IMDG") Code, it appears
that 'a gas' is the required test medium. For example, if the hazardous material offered for
transportation in a UN portable tank is water-reactive and oxygen-reactive, nitrogen would be the
preferred test medium, as there would be significant risk in using air; residual air or contaminants
could initiate a dangerous reaction or adversely affect product quality when the hazardous material
would again be introduced into the UN portable tank. Can you please validate that nitrogen, as a gas,
is an authorized test medium for the intermediate 2.5 year periodic leakage test on UN portable tanks
under the HMR? Included below are both the applicable HMR and IMDG Code regulations for your
reference:
HMR
§178.274 Specifications for UN portable tanks.
(a) General.
***
(3) Definitions. The following definitions apply for the purposes of design and construction
of UN portable tanks under this subpart:
internal pressure.
Leakage test means a test using gas to subject the shell and its service equipment to an
§180.605 Requirements for periodic testing, inspection and repair of portable tanks.
2.5 year periodic inspection and test must include at least an internal and external
(d) Intermediate periodic inspection and test. For IM and UN portable tanks the intermediate

<<<PAGE 4>>>

The Dow Chemical Company
Midland, Mi 48674
U.S.A.
examination of the portable tank and its fittings taking into account the hazardous materials
intended to be transported; a leakage test; and a test of the satisfactory operation of all service
equipment. Sheathing, thermal insulation, etc. need only be removed to the extent required
for reliable appraisal of the condition of the portable tank. For portable tanks intended for the
transportation of a single hazardous material, the internal examination may be waived if it is
leakage tested in accordance with the procedures in paragraph (h) of this section prior to each
filling, or if approved by the Associate Administrator. Portable tanks used for dedicated
transportation of refrigerated liquefied gases that are not fitted with inspection openings are
excepted from the internal inspection requirement.
***
(h) Pressure test procedures for specification 51, 56, 57, 60, IM or UN portable tanks. (1)
Each Specification 57 portable tank must be leak tested by a minimum sustained air pressure
of at least 3 psig applied to the entire tank. Each Specification 51 or 56 portable tank must be
tested by a minimum pressure (air or hydrostatic) of at least 2 psig or at least one and one-
half times the design pressure (maximum allowable working pressure, or re-rated pressure) of
the tank, whichever is greater. The leakage test for portable tanks used for refrigerated
liquefied gas must be performed at 90% of MAWP. Leakage tests for all other portable tanks
must be at a pressure of at least 25% of MAWP. During each air pressure test, the entire
surfáce of all joints under pressure must be coated with or immersed in a solution of soap and
water, heavy oil, or other material suitable for the purpose of detecting leaks. The pressure
must be held for a period of time sufficiently long to assure detection of leaks, but in no case
less than five minutes. During the air or hydrostatic test, relief devices may be removed, but
all the closure fittings must be in place and the relief device openings plugged. Lagging need
not be removed from a lagged tank if it is possible to maintain the required test pressure at
constant temperature with the tank disconnected from the source of pressure.
IMDG Code
6.7.2
Provisions for the design, construction, inspection and testing of portable
tanks intended for the transport of substances of class 1 and classes 3 to 9
6.7.2.1
Definitions
***
For the purposes of this section:
Leakproofness test means a test using a gas, subjecting the shell and its
MAWP;
service equipment to an effective internal pressure of not less than 25% of the
***
6.7.2.19.5
The intermediate 2.5-year periodic inspection and test shall at least include an
internal and external examination of the portable tank and its fittings with due

<<<PAGE 5>>>

The Dow Chemical Company
Midland, MI 48674
USA
regard to the substances intended to be transported, a leakproofness test and a
test of the satisfactory operation of all service equipment.***
I trust this is sufficient information for issuance of a letter of interpretation. If additional information
is needed, please contact me.
Sincerely,
John Heater
John Heater
Transportation Safety and Security Specialist
The Dow Chemical Company
100 Independence Mall West
Philadelphia, PA 19106
Phone: (215) 592-3157
E-mail: jheater@dow.com