# Catalina Composites — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 17-0107
- **title:** Catalina Composites — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2018-02-13
- **effective on:** Not available
- **summary:** 17-0107 response to Catalina Composites concerning 178.71.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-17-0107.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-17-0107.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-17-0107
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/57321/170107.pdf
**body:**

<<<PAGE 1>>>

Ray Denny
Engineering Manager
Catalina Composites
11700 Monarch Street
Garden Grove, CA 92841
Reference No. 17-0107
Dear Mr. Denny:
This letter is in response to your October 2, 2017, email requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to the design and construction
requirements for UN composite cylinders. Specifically, you refer to part 8.5.10.2 of ISO 11119-
2(E), Gas cylinders-Gas cylinders of composite construction-Specification and test
methods-Part 2. You ask if a cylinder can be fitted with any authorized pressure relief device
(PRD) and valve combination, if it passed the test in 8.5.10.2(b).
The answer is yes, provided the service equipment meets the requirements of § 178.71(d). The
test requirement you reference in ISO 11119-2(E) is for the cylinder itself, not the service
equipment.
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
Reprite
Chief, Standards Development Branch
Standards and Rulemaking Division

<<<PAGE 2>>>

Please submit this as a letter of interpretation. Let me know if you have any questions.
Thanks!
Eamonn
From: Ray Denny [mailto:RDenny@catalinacomposites.com]
Sent: Monday, October 02, 2017 12:53 PM
To: INFOCNTR (PHMSA) <INFOCNTR.INFOCNTR@dot.gov>
Subject: Request for Letter of Interpretation - ISO 11119-2:2012 Section 8.5.10.2
To whom it may concern,
I am writing to request a letter of interpretation from the DOT concerning a test requirement in the ISO 11119-2:2012
specification. The specific section in question is 8.5.10.2 (part of Fire Resistance Test). Based on the information given
in the specification (shown below) there are two options for testing.
8.5.10.2 Procedure
Two cylinders shall be fitted with either
3) the valves and PRDs intended for use (if known); or
b) a valve fitted with bursting disc set to operate at between pr and 1,15 x pr
if the test is conducted with the PRDs and valve intended for use in service i.e. option a). the specification of
the valve and PRDs shall be marked on the design drawing and the approval certificate
It is our assumption that if option b) is selected then the cylinder would then be approved for any valve and PRD
combination. We would like to request a letter of interpretation from the DOT on this subject. Please let me know if
you need any additional information.
Thank you,
Ray Denny
Engineering Manager
Direct: 714.793.5755 Main: 714.894.5300
CATALINA
Email:
rdenny@catalinacomposites.com
ComPoSITES
Website: www.catalinacomposites.com
DIVISION OF CATALINA CYLINDERS
Address:
11700 Monarch St., Garden Grove, CA 92841
1