# HazMat Resources, Inc. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 17-0122
- **title:** HazMat Resources, Inc. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2018-07-12
- **effective on:** Not available
- **summary:** 17-0122 response to HazMat Resources, Inc. concerning 178.345, 178.347.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-17-0122.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-17-0122.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-17-0122
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/60216/170122.pdf
**body:**

<<<PAGE 1>>>

0
U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
1200 New Jersey Avenue, SE
Washington, DC 20590
JUL 1 2 2018
Mr. Danny Shelton
President
HazMat Resources, Inc.
124 Rainbow Drive, Suite 24 71
Livingston, TX 77399-1024
Reference No. 17-0122
Dear Mr. Shelton:
This letter is in response to your November 1, 2017, email requesting clarification of the
Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to the marking and
inspection of U.S. Department of Transportation specification cargo tank motor vehicles
(CTMV). We have paraphrased and answered your questions as follows:
Q 1. You ask if the manufactured thickness must be marked on a nameplate when the
manufacturer builds in a corrosion allowance.
Al. The answer is yes. As prescribed in§ 178.345-14(b)(13) and (14), the manufactured
thickness is required to be marked on a CTMV nameplate when additional thickness is
provided by the manufacturer for corrosion allowance.
Q2. You note that a CTMV is not required to have a vacuum breaker if its tank is designed to
be loaded by vacuum or built to withstand a full vacuum. Therefore, you ask how a
registered inspector is to determine if the CTMV meets the specification requirement if
there is no indication on the nameplate that its tank is designed to be loaded by vacuum
or built to withstand a full vacuum.

<<<PAGE 2>>>

A2. Section § 178.345-14(b) of the HMR prescribes the information required to be marked on
a cargo tank's nameplate, in addition to any applicable information required by the
ASME Code. Paragraph UG-116(a)(4) in Section VIII of the 2015 ASME Code requires
the maximum allowable working pressure (MA WP) to be marked on the nameplate as
"maximum allowable working pressure (internal or external)," when specified as a design
condition. Consequently, if the marked MA WP ( external) is below 1 atmosphere
(14. 7 psi), it does not meet the exemption requirements of § 178 .34 7-4(b) and vacuum
relief devices (e.g., breaker) are required.
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
A-C. \
Shane C. Kelley
Director,
Standards and Rulemaking Division
Office of Hazardous Materials Standards

<<<PAGE 3>>>

January, lkeya CTR (PHMSA)
From:
Sent:
To:
Subject:
Foster, Glenn (PHMSA)
Monday, November 06, 2017 12:26 PM
Dodd, Alice (PHMSA); January, Ikeya CTR (PHMSA)
Issues with Specification Plates
11- O(d-J.-
Alice/ lkeya,
Please have the following inquiry checked in as a request for a Letter of Interpretation and assign it to a Specialist.
Thanks,
Glenn
From: Daniel Shelton [mailto:dshelton@hazmatresources.com]
Sent: Wednesday, November 01, 2017 10:39 AM
To: Foster, Glenn (PHMSA) <Glenn.Foster@dot.gov>
Cc: Bomgardner, Paul (FMCSA) <paul.bomgardner@dot.gov>; Fleener, Arthur (FMCSA) <arthur.fleener@dot.gov>; Ellis,
Suzanne (FMCSA) <Suzanne.Ellis@dot.gov>; Ford, David (FMCSA) <david.ford@dot.gov>; Simmons, James (FMCSA)
<james.simmons@dot.gov>; Solomey, Joe (OST) <Joe.Solomey@dot.gov>
Subject: Issues with Specification Plates
Good morning Mr. Foster,
When a DOT 407 stainless steel cargo tank is manufacturer, it is my understanding that the manufactured thickness is
required to be on the specification plate so one can calculate the corrosion allowance when performing a thickness test.
Question: Is the manufactured thickness required to stamped on the specification plate for a cargo tank when the
manufacture builds in a corrosion allowance.
It is my understand that a DOT 407 is not required to have a vacuum breaker if the tanks is "designed to be loaded by
vacuum" or "built to withstand full vacuum". How does a registered inspector determine if the cargo tank meets the
specification requirement when there is no indication on the specification plate that the cargo tank is "designed to be
loaded by vacuum" or "built to withstand full vacuum"?
Question: How does the registered inspector determine whether or not a vacuum breaker is required on a DOT 407
cargo tank.
Regards
Glenn, can you please confirmed that you received this message