# Dominion Technology Gases Ltd. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 18-0127
- **title:** Dominion Technology Gases Ltd. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2019-04-08
- **effective on:** Not available
- **summary:** 18-0127 response to Dominion Technology Gases Ltd. concerning 180.205, 180.207.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-18-0127.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-18-0127.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-18-0127
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/71061/180127.pdf
**body:**

<<<PAGE 1>>>

0
U.S. Department
of Transportation
· Pipeline and Hazardous
Materials Safety
Administration
1200 New Jersey Avenue, SE
Washington, DC 20590
APR O 8 2019
Eric Watson
Dominion Technology Gases Ltd.
Howe Moss Avenue
Kirkhill Industrial Estate
Dyce, Aberdeen AB21 0GP
United Kingdom
Reference No. 18-0127
Dear Mr. Watson:
This letter is in response to your October 5, 2018, email requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to cylinder requalification. You
state that your company has a fleet of United Nations (UN) ISO 9809-2, USA/M8304 cylinders
that you intend to retest (requalify) in the United Kingdom under ISO 6406 once they reach their
10-year requalification period. However, you note that testing will be done without a United
States Requalification Identification Number (RIN). Specifically, you ask whether these
cylinders may be used and transported in the United States after being requalified.
The answer is no. UN pressure vessels due for requalification cannot be filled and offered for
transportation in commerce unless they have been successfully requalified and marked in
accordance with the HMR (see§ 180.207(a)(2)). Section 180.205(b) states that no person may
represent that a repair or requalification of a cylinder has been performed in accordance with the
HMR unless that person holds a current approval issued under the procedural requirements in
Subpart I of 49 CFR Part 107 (see§ 107.801). Therefore, the facility where the cylinders are to
be tested (requalified) must be an approved and authorized RIN holder.

<<<PAGE 2>>>

If a facility is not an authorized RIN holder and seeks approval to engage in the requalification of
UN pressure receptacles, an Independent Inspection Agency (IIA) must conduct a review of a
facility's requalification operations. Once the review has been completed with satisfactory
results, the applicant (ex., Dominion Technology Gases Ltd.) must submit a letter of
recommendation from the IIA, an inspection report, and an application certifying that the facility
will perform requalification operations for UN pressure receptacles in compliance with the
applicable requirements of the HMR (see§ 107.805).
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
Der 'nd n
Chief, Standards Development Branch
Standards and Rulemaking Division

<<<PAGE 3>>>

Dodd, Alice (PHMSA)
From: INFOCNTR (PHMSA)
Sent:
To:
Subject:
Attachments:
Wednesday, October 10, 2018 1:10 PM
Hazmat Interps
FW: Cylinder Re-qualification
S_S8157811_Flaschenzeichnung.pdf; 6_S815781l_Einschlag.pdf
Hello Alice and lkeya,
Below is a request for a letter of interpretation.
Thanks,
Jonathon, HMIC
From: Eric_ Watson@Praxair.com [mailto:Eric_ Watson@Praxair.com]
Sent: Friday, October 05, 2018 11:37 AM
To: INFOCNTR (PHMSA) <INFOCNTR.INFOCNTR@dot.gov>
Subject: Cylinder Re-qualification
The mailing address for the letter of interpretation is:
Dominion Technology Gases Ltd
Howe Moss Avenue
Kirkhill Industrial Estate
Dyce
Aberdeen
AB21 0GP
UK
For attention of Eric Watson
Hey Jonathon,
I've looking in FM and only saw letters that pertained to ISO standard 11119-2.
Since they've already spoken with APD, and there aren't any letters pertaining to his particular standard, I've
put in your box to move his request to the next level.
-Breanna
---------------------
To Whom it Concerns,
Could I ask for a letter of interpretation please, that could explain why retesting (requalifing) these UN, ISO 9809-2,
USA/M8304 cylinders in the UK under ISO standard 6406, will not allow their continued use
to be transported in USA.
Eric Watson
Engineering Support Manager-Dominion Gas
1

<<<PAGE 4>>>

Telephone +44 1224 215663
Mobile: +44 7711 367505
www.dominion-gas.com
From:
To:
Date:
Subject:
"Pascal, Irwin (PHMSA)" <irwin.pascal@dot.gov>
"Eric Watson@Praxair.com" <Eric Watson@Praxair.com>
01/10/201814:37
RE: Cylinder Re-qualification
••• Please note the message below originated on the Internet. Please use ca ution when replying or opening links or attachments. '**
Good Morning Eric
It is my understanding that once the requalification is performed by an Authorized RIN holder in accordance with 49 CFR § 180.207,
then yes the cylinders would be allowed in the USA, providing that the service life is not exceeded. You can also request an official
letter of interpretation from PHMSA's Standard Division (202) 366~ 8553 (infocntr@dot.gov) .
Respectfully
Irwin Pascal CDGP
Transportation Specialist
Pressure Vessels Branch
Approvals and Permits Division - PHH-30
OHMS, PHMSA, U.S. DOT
Office: (202) 366-8181
Fax: (202) 366 3753
East Building, E23-412
1200 New Jersey Ave., SE
Washington, D.C. 20590-0001
From: Bartrum, Zeudi CTR (PHMSA) On Behalf Of Approvals (PHMSA)
Sent: Friday, September 28, 2018 3:54 PM
To: Pascal, Irwin (PHMSA) <irwin.pascal@dot.gov>
Subject: FW: Cylinder Re-qualification
Irwin,
Please see the email below. Thanks.
Zeudi
From: Eric Watson@Praxair.com (mailto:Eric Watson@Praxair.com)
Sent: Wednesday, September 26, 2018 10:53 AM
To: Approvals (PHMSA) <Approvals@dot.gov>
Subject: Cylinder Re-qualification
To Whom it concerns,
2

<<<PAGE 5>>>

Below is the correspondence trail regarding cylinder re-qualification following the original e-mail
We have gas cylinders in our fleet which were manufactured by Worthington Cylinders GmbH - Austria, to UN, ISO 9809-
2, USA M8304.
When these cylinders reach their 10 year re-qualification period, we intend to have the cylinders re-tested by UT (UE) in
the UK to ISO 6406 standard (or replacement)
will this re-test also allow continued use of the cylinders in USA if required?
Mr. Watson,
I am working with my colleague in our engineering office to determine the appropriate response to your below email. I will get back
to you shortly.
Regards,
Andrew Eckenrode
Eric,
I ended up having to speak with some folks in our Pressure Vessels Branch about this and they are of the opinion that the cylinder
must be requalified by a RIN holder in order to be transported within the United States under the HMR. I do not have a regulatory
citation that I can point to that confirms this, so you may want to request a letter of interpretation from our Standards and
Rulemaking Division.
Regards,
Andrew
Hello Andrew,
As previously advised we have gas cylinders in our fleet which were manufactured by Worthington Cylinders GmbH -
Austria, to UN, ISO 9809-2, USA M8304.
It is my understanding that these cylinders can be transported within the United States during the 10 year period after manufacture
& testing.
When these cylinders reach their 10 year re-qualification period, we intend to have the cylinders re-tested by UT (UE) in
the UK to ISO 6406 standard (or replacement ISO 18119 when issued)
Your e-mail indicates that the retesting of these cylinders by UT in the UK to relevant ISO standard will not be accepted
for transport in USA?
WiUa RIN holder be able to requalify these cylinders by UT to satisfy both US DOT & ISO 6406?
Regards
Eric Watson
Eric,
If these cylinders are requalified by a RIN holder that is authorized to perform UE testing, there should be no issue.
I am trying to avoid making a definitive statement regarding whether it is absolutely necessary as cylinder requalification is not my
3

<<<PAGE 6>>>

area of expertise. For a definitive answer, I would recommend talking with our Pressure Vessels Branch and/or requesting a letter of
interpretation.
Let me know if you have any additional questions.
Regards,
Andrew Eckenrode (PHMSA) has suggested I contact yourselves regarding this subject.
Eric Watson
Engineering Support Manager-Dominion Gas
Telephone +44 1224 215663
Mobile: +44 7711 367505
www.dominion-gas.com
From:
To :
Date:
Subject:
"Eckenrode, Andrew (PHMSA)" <andrew.eckenrode@dot.gov>
"Eric Watson@Praxair.com" <Eric Watson@Praxair.com>
26/09/2018 15:07
RE: Cylinder Re-qualification
••• Please note the message below originated on the Internet. Please use caution when replying or opening links or attachments. ***
Eric,
They are in DC. You can try 202-366-4535 as well. The person answering those numbers might not be at their desk, so you can
always try back latter. Please feel free to also reach out to them via email at approvals@dot.gov.
Let me know if you have any further issues.
Regards,
Andrew
From: Eric Watson@Praxair.com <Eric Watson@Praxair.com>
Sent: Wednesday, September 26, 2018 10:01 AM
To: Eckenrode, Andrew (PHMSA) <andrew.eckenrode@dot.gov>
Subject: RE: Cylinder Re-qualification
Andrew,
Where are they based no answer at that number
Regards
Eric Watson
Engineering Support Manager-Dominion Gas
Telephone +44 1224 215663
Mobile: +44 7711 367505
www. dominion-gas. com
From:
To:
Date:
Subject:
"Eckenrode, Andrew (PHMSA)" <andrew.eckenrode@dot.gov>
"Eric Watson@Praxair.com" <Eric Watson@Praxair.com>
26/09/2018 14:00
RE: Cylinder Re-qualification
4

<<<PAGE 7>>>

Eric,
approach.
Regards,
Andrew
Call 202-366-4511 and ask to speak with someone within the Pressure Vessels Branch. Let me know if you have any issues with that
From: Eric Watson@Praxair.com <Eric Watson@Praxair.com>
Sent: Wednesday, September 26, 2018 7:43 AM
To: Eckenrode, Andrew (PHMSA) <andrew.eckenrode@dot.gov>
Subject: RE : Cylinder Re-qualification
Hello Andrew,
Could you please advise how to contact the Pressure Vessels Branch.
Regards
Eric Watson
Engineering Support Manager-Dominion Gas
Telephone +44 1224 215663
Mobile: +44 7711 367505
www.dominion-gas.com
From:
To:
Date:
Subject:
"Eckenrode, Andrew (PHMSA)" <andrew.eckenrode@dot.gov>
"Eric Watson@Praxair.com" <Eric Watson@Praxair.com>
26/09/2018 12:21
RE: Cylinder Re-qualification
Eric,
If these cylinders are requalified by a RIN holder that is authorized to perform UE testing, there should be no issue.
I am trying to avoid making a definitive statement regarding whether it is absolutely necessary as cylinder requalification is not my
area of expertise. For a definitive answer, I would recommend talking with our Pressure Vessels Branch and/or requesting a letter of
interpretation.
Let me know if you have any additional questions.
Regards,
Andrew
From: Eric Watson@Praxair.com <Eric Watson@Praxair.com>
Sent: Wednesday, September 26, 2018 3:07 AM
To: Eckenrode, Andrew (PHMSA) <andrew.eckenrode@dot.gov>
Subject: RE: Cylinder Re-qualification
Hello Andrew,
As previously advised we have gas cylinders in our fleet which were manufactured by Worthington Cylinders GmbH -
Austria, to UN, ISO 9809-2, USA M8304.
It is my understanding that these cylinders can be transported within the United States during the 10 year period after manufacture
& testing.
5

<<<PAGE 8>>>

When these cylinders reach their 10 year re-qualification period, we intend to have the cylinders re-tested by UT (UE) in
the UK to ISO 6406 standard (or replacement ISO 18119 when issued}
Your e-mail indicates that the retesting of these cylinders by UT in the UK to relevant ISO standard will not be accepted
for transport in USA?
Will a RIN holder be able to requalify these cylinders by UT to satisfy both US DOT & ISO 6406?
Regards
Eric Watson
Engineering Support Manager-Dominion Gas
Telephone +44 1224 215663
Mobile: +44 7711 367505
www.dominion-gas.com
From:
To:
Date:
Subject:
"Eckenrode, Andrew (PHMSA)" <andrew.eckenrode@dot.gov>
"Eric Watson@Praxair.com" <Eric Watson@Praxair.com>
25/09/2018 20:03
RE: Cylinder Re-qualification
Eric,
I ended up having to speak with some folks in our Pressure Vessels Branch about this and they are of the opinion that the cylinder
must be requalified by a RIN holder in order to be transported within the United States under the HMR. I do not have a regulatory
citation that I can point to that confirms this, so you may want to request a letter of interpretation from our Standards and
Rulemaking Division.
Regards,
Andrew
From: Eric Watson@Praxair.com [mailto:Eric Watson@Praxair.com]
Sent: Friday, September 21, 2018 5:30 AM
To: Special Permits (PHMSA) <specialpermits@dot.gov>
Subject: RE: Cylinder Re-qualification
Hello Andrew,
Have you and your colleague had the opportunity to look into this subject ?
Regards
Eric Watson
Engineering Support Manager-Dominion Gas
Telephone +44 1224 215663
Mobile: +44 7711 367505
www. dominion-gas. com
From:
To:
Date:
Subject:
Sent by:
"Special Permits (PHMSA)" <specialpermits@dot.gov>
"Eric Watson@Praxair.com" <Eric Watson@Praxair.com>
13/09/2018 17:47
RE: Cylinder Re-qualification
"Eckenrode, Andrew (PHMSA)" <andrew.eckenrode@dot.gov>
Mr. Watson,
6

<<<PAGE 9>>>

I am working with my colleague in our engineering office to determine the appropriate response to your below email. I will get back
to you shortly.
Regards,
Andrew Eckenrode
From: Eric Watson@Praxair.com fm ailto:Eric Watson@Praxair.com]
Sent: Thursday, September 13, 2018 9:27 AM
To: Special Permits (PHMSA) <specialpermits@dot.gov>
Subject: Cylinder Re-qualification
To whom it concerns,
We have gas cylinders in our fleet which were manufactured by Worthington Cylinders GmbH - Austria, to UN, ISO 9809-
2, USA M8304.
When these cylinders reach their 10 year re-qualification period, we intend to have the cylinders re-tested by UT (UE) in
the UK to ISO 6406 standard (or replacement)
will this re-test also allow continued use of the cylinders in USA if required?
Regards
Eric Watson
Engineering Support Manager-Dominion Gas
Te~phone+441224215663
Mobile: +44 7711 367505
www.dominion-gas.com
This e-mail, including any attachments, is intended solely for the person or entity to which it is addressed ond may contain confidential, proprietary and/or non-public
material. Except as stated above, any review, re-transmission, dissemination or other use of, or taking of any action in reliance upon this information by persons or entities
other than an intended recipient is prohibited. If you receive this in error, please so notify the sender and delete the material from any media ond destroy any printouts or
copies.
7

<<<PAGE 10>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety Administration
East Building, PHH - 33
1200 New Jersey Avenue, Southeast
Washington, D.C. 20590
APPROVAL CA2006050031
(15th Revision)
ISSUED BY THE COMPETENT AUTHORITY OF THE UNITED STATES
EXPIRATION DATE: September 21, 2020
1.
APPROVAL HOLDER: Worthington Cylinders GmbH , Austria
Beim Flaschenwerk 1
A-3291 Kienberg bei Gaming
Austria
2. REGULATORY AUTHORITY: 49 CFR § 107.807 & 178.37
3 . SYNOPSIS: Worthington Cylinders GmbH is authorized to to
use the term Cro-Mo ly steel within the required levels for
4130X steel specified in 49 CFR 178.37 for the material
used for manufacturing DOT-3AA cyl inders . Worthington
Cylinders GmbH, Austria is also authorized to manufacturer
DOT 3AA cylinder designs: R0180 100 31 11 Rev 1, N5000 229
26 10, N2000 229 26 10, N1340 204 48 11-1 and UN ISO designs
(identified by drawing number): ISO 9809-1 N1600-
N65002295811-4, ISO 9809-2 N1500-N62002296611-2 Rev.1, I SO
9809 -1 N1200-N32002045211-1, I SO 9809 -1 R0300-R13501403611-
1 Rev.l, 9809-1 drawing number N1600-N6500 229 47 11-1,
9809-2 drawing number N1500-N6400 229 44 11-1, 9809-2
drawing numbers N1600-N6200 228 60 11-1 and N2500-N8500 268
50 and 9809 -1 drawing number R0600-R1600 17 8 35 11 Rev.1,
9809 - 2 drawing number N2500-N8500 268 50 11, 9809-1 drawing
number N1800-N5500 228 87 11-1, N1600-N6200 229 49 11,
N3000-N8800 268 30 11 and 9809-2 drawing number N2500-N8500
268 75 11-1 specification cylinders by the Billet
manufacturing method at the facility l ocated at the address
above, under the supervision of the Independent Inspection
Agency identified under section 5(b) of this approval.
4. BASIS: Thi s approva l is issued in response to Worthington
Cy linders GmbH, Austria 's application on July 28 , 2017 to
add one (1) DOT 3AA design, drawing number: Nl340 204 48
11-1 to their current CA Approval.
CA2006050031 (15th Rev) Page 1 of 5 Tracking Number: 2017080056

<<<PAGE 11>>>

5. PERIOD OF VALIDITY AND CONDITIONS OF APPROVAL: This
approval does not provide relief from any requirements of
the Hazardous Materials Regulations except as stated
herein. This approval is valid until the posted expirati on
date o r until terminated by the Associate Administrator for
Hazardous Materials Safety.
a. Approved Authority: The holder of this approval is
authorized to Manufacture and Mark the following DOT
specification cylinders under the supervision of an
independent inspection agency approved for that purpose in
accordance with§ 107.803:
DOT 3AA, UN ISO 9809-1 and UN ISO 9809-2 Cylinders -
Manufactured in accordance with§§ 178.35, 178.37,
178.69, 178 . 70 and 178.71.
Only designs on file with the department may be
manufactured and marked under the terms of this
approval .
b. Approved Independent Inspector (IIA): Only the
following IIA is currently authorized to conduct onsite
inspections at your manufacturing facility:
Bureau Veritas Austria GmbH,
Prinz-Eugen-Strasse 8-10,
A-1040 Wien, Austria
c. Registration number: M8304 is your assigned
registration number and must be marked on all DOT cylinders
manufactured under the terms of this approval.
6. SAFETY CONTROLS:
a. If DOT specification cylinder production has not been
undertaken for more than six months, The Pipeline and
Hazardous Materials Safety Administration must be
notified prior to resumption of production. Additional
sample testing and/or an onsite inspection may be
required prior to resumption of production, at the
discretion of PHMSA.
b. No deviation from designs, materials, method of
manufacture, inspection procedures or any technical
information submitted in support of the manufacturer's or
CA2006050031 (I 5th Rev) Page 2 of 5 Tracking Number: 2017080056

<<<PAGE 12>>>

inspector's applications for approval is authorized
unless approved in accordance with 6.d. of this approval.
c. Failure to assure adequate independent inspection and
verification will be grounds for termination or other
enforcement action as provided for in the regulations.
PHMSA must be notified in writing prior to a change in
independent inspection agency service companies.
d. Advanced notice and written approval is required before
any of the following can be implemented:
1) Technical changes in the manufacturing process or
procedures are made.
2) Changes in the approved designs on file. However,
additional approval is not required for design
changes to the UN ISO designs identified above,
provided the changes to the design are within the
previously approved design type family as identified
in the applicable UN ISO specification on file with
PHMSA, and as certified by the currently approved
Independent Inspection Agency on file with PHMSA.
New designs that fall outside the approved design
type family, which are identified as a new design
type family within the confines of the authorized UN
ISO specification, or production of new UN ISO
specification cylinder not currently authorized by
PHMSA, must be approved prior to manufacture under
the terms of this approval.
3) Adding a new DOT or UN ISO specification design, not
meeting the requirements above, or which does not
currently have design change criteria listed in the
respective UN ISO specification (i.e. UN ISO 11120
tubes), or authorization to manufacture a cylinder
specification not currently authorized to be
manufactured under the authority of this approval.
e. If non-technical information, submitted in your
application for approval changes, Approvals and Permits
must be notified, in writing, within 20 days.
CA2006050031 (15th Rev) Page 3 of 5 Tracking Number: 2017080056

<<<PAGE 13>>>

7. SPECIAL PROVISIONS:
a. A current copy of this approval must be maintained and
made available for examination at each location where
cylinders are manufactured.
8. GENERAL PROVISIONS:
a. Failure by any person to comply with the terms and
conditions of this approval and the Hazardous Materials
Regulations, 49 CFR Parts 171-180, may result in the
modification, suspension or termination of that person's
authority to use this approval. Failure to comply may
also subject that person to penalties prescribed by 49
U.S.C. §§ 5123 and 5124. This approval may be modified,
sus pended or terminated in its entirety if that action is
justified in light of changes in circumstances or
additional information not available when this approval
was issued. Unless immediate modification, suspension or
termination is necessary to avoid a risk of significant
harm to persons or property, befo re action is taken, that
person will be notified and provided with an opportunity
to show why the proposed action should not be taken.
b. Each "Hazmat employee," as defined in § 171. 8, who
performs a function subject to this approval must be
provided training on the requirements and conditions of
this approval in addition to the training required by
§§ 172.700 through 172.704.
c. Any person operating under the terms of this approval
must comply with the security plan requirement in Subpart
I of Part 172 of the HMR, when applicable.
d. This approval, as revised, supersedes all previous
versions.
CA200605003 l (15th Rev) Page 4 of 5 Tracking Number: 2017080056

<<<PAGE 14>>>

Issued in Washington, D.C.
Dated: 01/17/2018
;\ )!ldl!/ 'Jt! _ // ,, ,1/;
/ ✓--;
./
For William Schoonover
Associate Administrator for Hazardous Materials Safety
Address all inquiries to:
Materials Safety, Pipeline
Administration, Department
20590. Attention: PHH-30.
Associate Administrator for Hazardous
and Hazardous Materials Safety
of Transportation, Washington, D.C.
CA200605003 I (I 5th Rev)
Page 5 of 5 Tracking Number: 2017080056

<<<PAGE 15>>>

Einschlagskizze ■-~ WORTHINGTON
- INDUSTRIES
F S81578'11
Gasbezeichnung:
Sonderangaben:
Abnahmedatum
(Jahr/Monat)
Leergewicht
(ohne Ventil)
"UN"-Stempel
(Grol1e 10 mm)
Abnahmestempel
(Bureau Veritas)
Schrifthohe: 8 mm

<<<PAGE 16>>>

Threaded to customer's requirement
min. 9,9
Calculation of wall thickness
I
D ( IO x F x R - Ph x .fj J
~ I Q = - X ] - ' eg = 6,52 mm
2 JO X F X Re g
~ I ~
Guaranteed minimum wall thickness:
I
~ a'= 6,6 mm
C>
&t') -
------r------t--
00
..... min. 6,6
' C> - --- <O F= - = 0, 735
&t') -
I 0 229 ±1% _
0,65 0,65
.
Reg / Rmg 990/ 1120
-----
+-------
-
min. ~ -
I
I N
..... .....
<D C:
It)
_J .,;-
· e
~~+~,,1
, I /
N
I
&t')
.,;- ,..:
R~~
.....
N
C: C:
·e · e
All rights for using and copying of this drawing belong to: COPYRIGHT © 2010
rJ Alie R echte der Benutzung und Vervielfiiltigung dieser Zeichnung liegen bei:
+) Allowable gases to be filled: WORTHINGTON
• UN1002 Air Beim Flaschenwerk 1 CYL INDERS
• Gases of arouo 1,4,5,6,7,8,9, 10 accordina to ISO 11114-1 A-3291 Kienberg/Gaming A Worthington lr1dustries Company
Specification Material 34CrMo4 - Steel Yield point (Reg} 990 MPa
ISO 9809-2:2010 Heat treatment quenched and tempered U. TS. (Rmg I Rmmax) 1120/1240 MPa
T ype EXTRA• 5 Chemical composition Elongation min. 12 % (Lo=S,65 .J So)
Name of gas +) C 0,32 - 0,35 % s ,:; 0,005 % Impact value (trans.) A-value 35 Jlcm'
Water capacity 15-62 I Mn 0,65 - 0,80 % Cr 0,95-1,15 % ISO-V (-50°C) 8-value 50 Jlcm'
Filling weight -
kg Si 0,15-0,30 % Mo 0,17-0,27 % Rev. 0 Rev. 1 Rev. 2 Rev. 3
Working pressure (Pw) :S 310 bar p ,:; 0,010 % Ni ,:; 0,20 % PJ Drawn PJ
Test pressure (Ph} 465 bar V +Nb+ Ti+B+Zr
~ 0,15 % 29.09.10 Date 05.11 .10
Weight empty 29-80 kg WF Checked WF
Title: 04.10.10 Date 05.11 .10
Seamless Steel Cylinder Drw. no.
Notes: Manufacturer's process: from billet N1500-N6200 229 6611-2 Rev.1
Burst pressure Pb~ 744 bar; Yield pressure Py~ 633 bar
- **truncated:** false