# Hasa, Inc. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 20-0053
- **title:** Hasa, Inc. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2021-04-27
- **effective on:** Not available
- **summary:** 20-0053 response to Hasa, Inc. concerning 173.28.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-20-0053.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-20-0053.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-20-0053
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/74946/200053.pdf
**body:**

<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
1200 New Jersey Avenue, SE
Washington, DC 20590
April 27, 2021
Mr. Dave Johnson
Hasa, Inc.
23119 Drayton Street
Saugus, CA 91350
Reference No. 20-0053
This letter is in response to your July 17, 2020, letter and subsequent emails requesting
clarification of the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180) applicable
to pressure differential testing. In your letter, you state that your company reuses and refills 5,
15, 30, and 55 gallon polyethylene drums—rated for Packing Group (PG) II or III materials—
with materials similar to materials the drums previously contained. You ask whether your
company’s proposed test procedure, as outlined below, is in compliance with the pressure
differential testing requirements specified in paragraph 2 of Appendix B to Part 178 - Alternative
Leakproofness Test Methods.
You described your proposed test procedure as follows:
• A test fixture with a single pressure gauge is connected to an opening in the drum. All
other openings on the drum are sealed with closures.
• Utilizing a compressed air source and hand valve, the drum under test is pressurized to
3 psig, as indicated on a single pressure gauge measuring the internal pressure of the
drum.
• A hand valve is closed, isolating the air source from the drum and pressure gauge
measuring the internal pressure of the drum.
• The pressure gauge is monitored for one minute. If no pressure drop is observed on the
pressure gauge, the drum is considered to pass the test and is marked accordingly, per
§ 173.28. If the pressure is not maintained, the drum is considered to fail and is marked
out of service and disposed of through a plastic recycler.
It is the opinion of this Office that the proposed test procedure you describe complies with the
pressure differential test requirements in paragraph (2) of Appendix B to Part 178. Therefore,
the PG II and III polyethylene drums that successfully pass this test may be reused and refilled
under § 173.28, provided these packagings comply with all applicable requirements of the HMR.
Please be advised that plastic drums may expand under pressure. Therefore, it is recommended

<<<PAGE 2>>>

that the drums be pressurized to 20kPa and held at that pressure prior to testing. In addition, as it
may be difficult to detect a slow leak, it is also recommended that a low-pressure gauge be used.
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
T. Glenn Foster
Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division

<<<PAGE 3>>>

Edmonson
20-0053
HB&B
, Inc.
Shane Kelley
Director, Standards and Rulemaking Division
US DOT/PHMSA (PHH-10)
1200 New Jersey Avenue, SE East Building, 2nd Floor
Washington, DC 20590
Subject: Letter of Interpretation concerning 49 CFR Part 178, Appendix B - Alternative Leakproofness
Test Methods
Dear Mr. Kelley,
Hasa is requesting a letter of interpretation concerning the alternate leakproofness test methods
contained in 49 CFR Part 178, Appendix B. Specifically, Hasa is seeking a determination that our test
method and procedure for reusing non-bulk plastic packages is compliant with the Pressure differential
test regulations contained in paragraph (2) of 49 CFR Part 178, Appendix B. See referenced paragraph
below:
(2) Pressure differential test. The packaging shall be restrained while either pressure or a
vacuum is applied internally. The packaging must be pressurized to the pressure required by
§178.604(e) of this subchapter for the appropriate packing group. The method of restraint must
not affect the results of the test. The test must be conducted for a period of time sufficient to
appropriately pressurize or evacuate the interior of the packaging and to determine if there is
leakage into or out of the packaging. A packaging passes the pressure differential test if there is
no change in measured internal pressure.
Hasa is refilling plastic poly 5,15,30, and 55 gallon drums with the same type of products in accordance
with CFR § 173.28. All containers are being packaged in Packing Group II or III UN approved
containers.
Hasa is specifically requesting if the following test procedure methodology is compliant with paragraph
(2) of 49 CFR Part 178, Appendix B:
• A test fixture with a single pressure gauge is connected to an opening in the drum. All other
drum openings are sealed with closures.
• Utilizing a compressed air source and hand valve the drum under test is pressurized to 3 psig as
indicated on a single pressure gauge measuring the internal pressure of the drum.
• A hand valve is closed isolating the air source from the drum and pressure gauge measuring the
internal pressure of the drum.
Hasa, Inc. 23119 Drayton Street, Saugus, CA 91350 Phone: 661-259-5848 Fax: 661-259-1538

<<<PAGE 4>>>

Please advise if the above leakproofness test methodology procedure complies with the current DOT
regulatory requirements for conducting the pressure differential test under 49 CFR Part 178, Appendix
B, paragraph (2) for the reuse and refilling of packages under 49 CFR 173.28.
If you need any further information or have any questions, please feel free to contact myself at (925)
432-3866.
Sincerely,
Dish
Dave Johnson
Hasa Inc.
Hasa, Inc. 23119 Drayton Street, Saugus, CA 91350
Phone: 661-259-5848
Fax: 661-259-1538
- **truncated:** false