# Cylinder Sales and Testing, LLC d/b/a Coastal Hydrotesting — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 20-0086
- **title:** Cylinder Sales and Testing, LLC d/b/a Coastal Hydrotesting — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2021-07-28
- **effective on:** Not available
- **summary:** 20-0086 response to Cylinder Sales and Testing, LLC d/b/a Coastal Hydrotesting concerning 180.205, 180.207, 180.209.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-20-0086.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-20-0086.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-20-0086
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/75691/200086.pdf
**body:**

<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
1200 New Jersey Avenue, SE
Washington, DC 20590
July 28, 2021
Mr. Jeffery Strong
Manager
Cylinder Sales and Testing, LLC
d/b/a Coastal Hydrotesting
7120 Golden Ring Road, Ste. 104
Baltimore, Maryland 21221
Reference No. 20-0086
Dear Mr. Strong:
This is in response to your November 3, 2020, letter requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to hydrotesting and ultrasonic
examination of foreign compressed gas cylinders. Your questions have been paraphrased and
answered below.
Q1. You ask whether International Organization for Standardization (ISO) cylinders,
manufactured with a country of approval other than the United States, must be retested in
accordance with the Requalification of Cylinders table found in § 180.209 or the
requirements for requalification of United Nations (UN) pressure receptacles specified in
§ 180.207.
A1. As discussed on page 85388 of the final rule issued under Docket No. PHMSA-2011-
0140 (12/28/2020, 85 FR 85380) (HM-234) ISO cylinders with a country of approval of
the United States or Canada must be tested in accordance with the test requirements in
§ 180.207 which specifies requirements for the requalification of UN pressure
receptacles. ISO cylinders must be manufactured with a country of approval of the
United States or Canada to be considered an approved package (See § 180.205(a)).
Q2. You ask whether is it acceptable to perform an ultrasonic examination on foreign ISO
cylinders (i.e., manufactured with a country of approval other than the United States or
Canada) under your current retester’s certification letter and your current calibration
standards manufactured for UN/ISO 9809-1,2,3 USA cylinders.

<<<PAGE 2>>>

A2. The answer is no. Your company’s Requalifier Identification Number (RIN) H949,
authorizes:
“DOT cylinder specification(s): 3A, 3AA, 3AL, UN ISO: 9809-1, 9809-2 and 9809-3 and Special
Permit(s): 6557 and 14175 by the “ultrasonic” test method, in accordance with Special Permit(s):
16461, 14546 and 20831.”
PHMSA retester’s certification letters authorize RIN holders testing authority for DOT
approved cylinders. Your company’s RIN does not specifically authorize testing UN ISO
cylinders with a country of approval other than the United States or Canada.
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
T. Glenn Foster
Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division

<<<PAGE 3>>>

Pollack
From: INFOCNTR (PHMSA)
To: Subject: Date: Dodd, Alice (PHMSA); Hazmat Interps
FW: Interpretation Request - Retesting Foreign UN/ISO Cylinders
Monday, November 9, 2020 1:48:42 PM
Attachments: Interpretation Request 11-3-20.docx
20-0086
Hi Alice,
Please see attached for a letter of interpretation request. Jonathon had spoken with Eamonn about
this situation, and Eamonn advised that whoever is assigned the letter speak with him regarding its
content.
Please contact our office with any questions.
Best,
Sarah (HMIC)
From: Nickels, Matthew (PHMSA)
Sent: Tuesday, November 3, 2020 10:13 AM
To: INFOCNTR (PHMSA) <INFOCNTR.INFOCNTR@dot.gov>
Cc: Nickels, Matthew (PHMSA) <Matthew.Nickels@dot.gov>
Subject: FW: Interpretation Request - Retesting Foreign UN/ISO Cylinders
From: Jeff Strong <jeff.strong@cylindersalesandtesting.com>
Sent: Tuesday, November 3, 2020 9:58 AM
To: Gale, John (PHMSA) <john.gale@dot.gov>
Cc: Dave Reeves <dave.reeves@cylindersalesandtesting.com>
Subject: Interpretation Request - Retesting Foreign UN/ISO Cylinders
CAUTION: This email originated from outside of the Department of Transportation (DOT). Do not click on links or
open attachments unless you recognize the sender and know the content is safe.
Good morning Mr. Gale,
Attached is a letter requesting an interpretation regarding the retesting of foreign UN/ISO cylinders.
If I need to forward this request to anyone else within your department or if you require any
additional information feel free to contact me.
Thank you,
Jeffery Strong
Manager
Cylinder Sales and Testing, LLC

<<<PAGE 4>>>

d/b/a Coastal Hydrotesting
7120 Golden Ring Road
Suite 104
Baltimore, MD 21221
443-904-0566 (cell)
Let us know how we're doing. Click Here.
- **truncated:** false