# Union Tank Car Company — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 23-0054
- **title:** Union Tank Car Company — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2023-09-21
- **effective on:** Not available
- **summary:** 23-0054 response to Union Tank Car Company concerning 179.100, 179.200.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-23-0054.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-23-0054.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-23-0054
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/77901/230054.pdf
**body:**

<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
1200 New Jersey Avenue, SE
Washington, DC 20590
September 21, 2023
Jon Schultz
Director of Fleet Engineering
Union Tank Car Company
175 W. Jackson Blvd.
Suite 2100
Chicago, IL 60604
Reference No. 23-0054
Dear Mr. Schultz:
This letter is in response to your June 22, 2023, email requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to the requirements in Part 179
for tank car jackets and jacket flashing. In your email, you describe several methods that you
believe could potentially be used to manufacture and repair flashed openings in tank car jackets:
1. Fillet weld of faying jacket sheets;
2. Intermittent fillet weld of faying jacket sheets (known as a skip weld) and sealant
caulking;
3. Non-welded joint consisting of faying jacket sheets with fasteners and gasket or sealant
caulk to form a shedding barrier to prevent ingress of weather past the jacket opening; or
4. Non-welded slip joint consisting of faying jacket sheets that overlap that allow for
expansion and contraction of faying surfaces.
Specifically, you ask whether the methods identified here are appropriate to meet the
requirements for tank car jackets in §§ 179.100-4(a) or 179.200-4(a).
The answer is that a tank car jacket is in compliance with §§ 179.100-4(a) or 179.200-4(a) if it is
metal, not less than 11 gauge thick, and flashed around all openings so as to be weather-tight.
Note that tank car jacket patches must have 100% welding around the jacket sheet edges and the
jacket patch repair must be in compliance with the original tank car design approval. We further

<<<PAGE 2>>>

emphasize that tank car jacket patches may not be secured without 100% welding around the
jacket patch. For example, the skip weld and caulk method described in option #2 above would
not be an acceptable method, unless otherwise authorized by a DOT Special Permit.
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
Dirk Der Kinderen
Chief, Standards Development Branch
Standards and Rulemaking Division

<<<PAGE 3>>>

Patrick
23-0054
From: Kelley, Shane (PHMSA)
To: Hazmat Interps
Cc: DerKinderen, Dirk (PHMSA); Patrick, Eamonn (PHMSA)
Subject: FW: Union Tank Car Company Letter of Interpretation Request
Date: Thursday, June 22, 2023 11:35:23 AM
Attachments: image001.png
Union Tank Car Company Jacket Flashing LOI Request.pdf
Please process as an interp
Thank you
From: Jonathan M Schultz <SchultzJ@utlx.com>
Sent: Thursday, June 22, 2023 11:33 AM
To: Kelley, Shane (PHMSA) <shane.kelley@dot.gov>
Subject: Union Tank Car Company Letter of Interpretation Request
CAUTION: This email originated from outside of the Department of Transportation (DOT). Do
not click on links or open attachments unless you recognize the sender and know the content
is safe.
Mr. Kelley,
Union Tank Car is seeking a letter of interpretation regarding 49 C.F.R. §179.100-4(a) and 49 C.F.R.
§179.200-4(a). Please see our formal request attached here.
Sincerely,
Jon Schultz | Director of Fleet Engineering
Union Tank Car Company | A Marmon/Berkshire Hathaway Company
175 W. Jackson Blvd. | Suite 2100 | Chicago, IL 60604
P: 312-431-2708 | schultzj@utlx.com| www.utlx.com

<<<PAGE 4>>>

175 W. Jackson Blvd., Suite 2100
Chicago, IL 60604
utlx.com
June 22, 2023
Mr. Shane Kelley
Director, Standards and Rulemaking Division
U.S. DOT/PHMSA
1200 New Jersey Avenue, SE East Building, 2nd Floor
Washington, DC 20590
Dear Mr. Kelley,
I am writing to request a letter of interpretation regarding 49 C.F.R. §179.100-4(a) and 49 C.F.R.
§179.200-4(a), specific to the following requirement:
“The entire insulation must be covered with a metal jacket of a thickness not less than 11 gauge
(0.1196 inch) nominal (Manufacturer's Standard Gauge) and flashed around all openings so as
to be weather tight.”
These sections are prescriptive that the jacket material must be at least 11-gauge metal but
non-prescriptive as to the method of ensuring the openings are flashed as weather tight. 49
C.F.R. §171.8 does not provide definitions for the language of weather tight and flashed. Based
on the webster dictionary, flashing1 is sheet metal used in waterproofing (as at roof valleys or
hips or the angle between a chimney and a roof). Weathertight2 is descriptive as proof against
wind and rain.
Typical manufacturing and repair methods of flashed openings of tank jackets include methods
of:
• Fillet weld of faying jacket sheets
• Intermittent fillet weld of faying jacket sheets (skip weld) and sealant caulking
• Non-welded joint consisting of faying jacket sheets with fasteners and gasket or sealant
caulk to form a shedding barrier to prevent ingress of weather past the jacket opening.
• Non-welded slip joint consisting of faying jacket sheets that overlap that allow for
expansion and contraction of faying surfaces.
1 “Flashing.” Merriam-Webster.com Dictionary, Merriam-Webster, https://www.merriam-webster.com/dictionary/flashing. Accessed 15 Jun.
2023.
2 “Weathertight.” Merriam-Webster.com Dictionary, Merriam-Webster, https://www.merriam-webster.com/dictionary/weathertight. Accessed
15 Jun. 2023.

<<<PAGE 5>>>

175 W. Jackson Blvd., Suite 2100
Chicago, IL 60604
utlx.com
Do the methods described above satisfy the requirements of 49 C.F.R. §179.100-4(a) and 49
C.F.R. §179.200-4(a) for flashing the jacket openings to a weather tight condition?
Sincerely,
Jon Schultz
Director of Fleet Engineering
- **truncated:** false