# Carbochem Inc, — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 23-0058
- **title:** Carbochem Inc, — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2023-11-30
- **effective on:** Not available
- **summary:** 23-0058 response to Carbochem Inc, concerning 173.22.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-23-0058.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-23-0058.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-23-0058
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/78081/230058.pdf
**body:**

<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
November 30, 2023
1200 New Jersey Avenue, SE
Washington, DC 20590
Mr. Gavin Kahn
President
Carbochem Inc,
308 East Lancaster Ave
Wynnewood, PA 19096
Reference No. 23-0058
Dear Mr. Kahn:
This letter is in response to your June 28, 2023, email pertaining to activated carbon transported
in accordance with the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180). In your
email, you note that chemically-activated carbon is often shipped as a Division 4.2
(Spontaneously Combustible Material) material due to its self-heating properties. To determine
the classification of your product, you arranged for your Carbochem® activated carbon grades to
be tested using United Nations (UN) Test N.4 “Test method for self-heating substances,
” in
accordance with Section 33.3.1.6 of the UN Manual of Test and Criteria (UNMTC). You state
that the results of the testing—as provided in your email—indicate that Carbochem® DC-50
(steam activated) exhibits no self-heating; while Carbochem® CA-50 (chemically activated)
shows some self-heating, but not at 140 °C with a 25mm cube sample. You ask for confirmation
that your test results accurately determine that your Carbochem products should not be classified
as Division 4.2 hazardous materials.
In accordance with § 173.22 of the HMR, it is the shipper's responsibility to properly classify a
hazardous material. This Office generally does not perform this function. However, based on
the test data and certification you provided, we agree that your company’s products—as
described in your email—do not meet the definition of a Division 4.2 hazardous material.
Accordingly, if your products do not meet any other hazard class as defined in part 173 of the
HMR, and are not a hazardous substance, hazardous waste, or marine pollutant, they are not
subject to the HMR.
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
T. Glenn Foster
Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division

<<<PAGE 2>>>

Andrews
23-0058
From: INFOCNTR (PHMSA)
To: Dodd, Alice (PHMSA)
Cc: Hazmat Interps
Subject: FW: Letter of Interpretation Request for Activated Carbon
Date: Friday, June 30, 2023 3:05:06 PM
Attachments: image001.png
Self Heating test per UN N.4 using Procedure 33.3.1.6 2023.pdf
Self Heating Result for Test UN N.4 - Carbochem DC-50 2-23.pdf
Self Heating Result for Test UN N.4 - Carbochem CA-50 2-23.pdf
Importance: High
Hello Alice,
Please see the below and attached interpretation requests.
Let me know if you need anything else.
Regards,
-Breanna
From: Gavin Kahn <Gavin.Kahn@carbochem.com>
Sent: Wednesday, June 28, 2023 9:54 AM
To: INFOCNTR (PHMSA) <INFOCNTR.INFOCNTR@dot.gov>
Cc: CARBOCHEM <HQ@carbochem.com>
Subject: Letter of Interpretation Request for Activated Carbon
Importance: High
CAUTION: This email originated from outside of the Department of Transportation (DOT). Do
not click on links or open attachments unless you recognize the sender and know the content
is safe.
To Whom it May Concern:
I have been working with Commissioner Carl Bentzel from the FMC regarding an issue with
the major shipping carriers that has been a problem for quite some time.
Background: Primary uses of Activated Carbon are purification of drinking water (Municipal
water treatment plants and beverage companies such as Coca-Cola and Pepsi) and
decolorizing food products such as sugar and other sweeteners, fruit juice, citric acid, MSG
etc. Obviously, the grades of Activated Carbon for these applications are all Food Grade
quality.
The United Nations has classified Activated Carbon produced by Chemical Activation to be
a Division 4.2 material because it exhibits self-heating properties and thus UN1362 was
applied to the product to designate this. The shipping lines used this as justification to
charge a freight premium on Activated Carbon as it was deemed dangerous cargo (also
permitting the carrier s to cancel freight bookings at their whim). They also applied this
classification to Activated Carbon produced by Steam Activation which is not valid, so they

<<<PAGE 3>>>

could benefit from greater revenues.
We arranged for a reputable laboratory with the necessary expertise to perform the self-
healing UN Test N.4 according to procedure Section 33.3.1.6, UN 2009 to determine if our
activated carbon products should be classified in Division 4.2. The results are attached for
our specific Carbochem® grades which confirm that our activated carbon should not be
classified in Division 4.2. The conclusion is based on the following analysis (test method
attached):
Carbochem® DC-50 (coal based, steam activated carbon, acid washed): No self-
heating detected for basic test at 140º C.
Carbochem® CA-50 (wood based activated carbon, chemically activated): Self-
heating detected at 140º C but not at 140º C with a 25 mm cube sample. Packing
Group II restriction not required as the packing size is less than 3 cubic meters
volume.
While we cannot speak for other grades of Activated Carbon, our grades are produced with
proprietary technology to ensure that they are exempt from Division 4.2 Classification, but
the shipping lines refuse to accept this.
Please advise how we can obtain a DOT/PHMSA letter of interpretation for clarification on
the federal process for classification of Activated Carbon.
Sincerely,
Gavin Kahn
President
Carbochem Inc,
308 East Lancaster Ave
Wynnewood,
PA 19096
Phone: (610)645-9200
Fax: (610)645-5501
E-Mail: Gavin.Kahn@carbochem.com

<<<PAGE 4>>>

SUITE 218, LONDON, ON,
ADDRESS: 700 COLLIP CIRCLE,
PHONE: (519) 777-5232
N6G 4X8,
CANADA
LCS
EMAIL: INFO@LCSLABORATORY.COM
WEB: WWW.LCSLABORATORY.COM
LABORATORY INC.
CERTIFICATE OF ANALYSIS
Client:
Carbochem Inc. 308 E.
Work Order:
PA 19096 USA
Lancaster Ave, Wynnewood
Date Received:
23MIS090
January 19, 2023
Date Analyzed:
Date Reported:
January 26-30, 2023
February 1, 2023
Requested By:
Gavin Kahn
Analysis:
Self-Heating Test
Client's
Self Heating Regulation per
Reference
reference:
UN
UN Test N.4. Paragraph.
Procedure:
33.3.1.6, UN 2009
Sample Description: Powder Activated Carbon, CA50
Laboratory sample ID: 23MIS090-SH1
Results:
Sample Size
Oven
Maximum Observed Sample
(mm)
Temperature (°C)
Observations
Temperature in the sample
Result
core (°C)
100 × 100 × 100
140
3041)
No smoke or
Self-Heating is
smoldering
detected
25 × 25x25
140
140
No smoke or
smoldering
Self-Heating is
not detected
100 × 100 x 100
120
124
No smoke or
Self-Heating is
smoldering
not detected
Comments:
: 1) The test was ste Sed atter the positive set ignition
UN defines positive Self Heating test in paragraph 33.3.1.6.4.1, as a test where the Maximum Observed Temperature in the
sample core exceeds the oven temperature by 60°C.
Note:
• Test duration is 24 hours unless the sample shows the self-ignition properties
Accuracy of the temperature reading is 1°C
Sample is tested in "as received" form
Test results pertain only to analysis of samples herein reported.
Ict
Analyst:
Stepan Reut, Ph.D.
Reviewer:
Raisa Stadnichenko, Ph.D.
LCS Laboratory Inc.
Page 1 of 1

<<<PAGE 5>>>

SUITE 218, LONDON, ON,
ADDRESS: 700 COLLIP CIRCLE,
PHONE: (519) 777-5232
N 6G 4X8,
CANADA
LCS
WEB: WWW.LCSLABORATORY.COM
EMAIL: INFO@LCSLABORATORY.COM
LABORATORY INC.
CERTIFICATE OF ANALYSIS
Client:
Carbochem Inc. 308 E.
Work Order:
23MIS090
Lancaster Ave, Wynnewood
Date Received:
PA 19096 USA
January 19, 2023
Date Analyzed:
January 26-30, 2023
Date Reported:
February 1, 2023
Requested By:
Gavin Kahn
Analysis:
Self-Heating Test
Client's
reference:
Self Heating Regulation per
UN
Reference
Procedure:
UN Test N.4. Paragraph.
33.3.1.6, UN 2009
Sample Description: Granular Activated Carbon, DC50
Laboratory sample ID: 23MIS090-SH2
Results:
Sample Size
Oven
Maximum Observed Sample
Observations
Result
(mm)
Temperature (°C)
Temperature in the sample
core (°C)
100 × 100 × 100
140
151
No smoke or
Self-Heating is
smoldering
not detected
Comments:
• UN defines positive Self Heating test in paragraph 33.3.1.6.4.1, as a test where the Maximum Observed Temperature in the
sample core exceeds the oven temperature by 60°C.
Note:
: Test duration is 24 hours unless the sample shows the self-ignition properties
Accuracy of the temperature reading is 1°C.
: Sample is tested in "as received" form
Test results pertain only to analysis of samples herein reported.
Analyst:
Stepan Reut, Ph.D.
Reviewer:
Raisa Stadnichenko, Ph.D.
LCS Laboratory Inc.
Page 1 of 1

<<<PAGE 6>>>

Copyright © United Nations, 2009. All rights reserved
33.3.1.6
Test N.4: Test method for self-heating substances
33.3.1.6.1
Introduction
to air at temperatures of 100 °C, 120 °C or 140 °C in a 25mm or 100mm wire mesh cube.
The ability of a substance to undergo oxidative self-heating is determined by exposure of it
33.3.1.6.2
Apparatus and materials
The following apparatus is required:
a)
a hot-air circulating type of oven with an inner volume of more than 9 litres and
capable of controlling the internal temperature at 100 °C, 120 °C or 140 °C + 2 °C;
cubic sample containers of 25 mm and 100 mm side, made of stainless steel net with a
mesh opening of 0.05 mm, with their top surface open; and
c)
Chromel-Alumel thermocouples of 0.3 mm diameter; one placed in the centre of the
sample and another between the sample container and the oven wall.
mesh opening of 0.60 mm, and slightly larger than the sample container. In order to avoid the effect of air
Each sample container should be housed in a cubic container cover made from a stainless steel net with a
of 0.595 mm and 150 × 150 × 250 mm in size.
circulation, this cover is installed in a second stainless steel cage, made from a net with a mesh size
33.3.1.6.3
Procedure
sample container and the container tapped several times. If the sample settles, more is added. If the sample is
The sample, powder or granular,
in its commercial form, should be filled to the brim of the
heaped it should be levelled to the brim. The container is housed in the cover and hung at the centre of the
sample and of the oven should be recorded continuously. The first test' may be conducted with a 100 mm
oven. The oven temperature should be raised to 140 °C and kept there for 24 hours. The temperature of the
cube sample. A positive result is obtained if spontaneous ignition occurs or if the temperature of the sample
exceeds the oven temperature by 60 °C. If a negative result is obtained, no further test is necessary. If a
determine whether or not packing group II should be assigned. If a positive result is obtained at 140 °C with
positive result is obtained, a second test should be conducted at 140 °C with a 25mm cube sample to
substance in a 100 mm sample cube should be performed:
the substance in a 100mm sample cube, but not a 25mm sample cube, then an additional test with the
(a) At 120 °C if the substance is to be transported in packagings of more than 450 litre
volume but not more than 3 m' volume; or
(b) At 100 °C if the substance is to be transported in packagings of not more
than 450 litres volume.
33.3.1.6.4
Test criteria and method of assessing results
33.3.1.6.4.1
sample exceeds the oven temperature by 60 °C during the 24 hour testing time. Otherwise, the result is
A positive result is obtained if spontaneous ignition occurs or if the temperature of the
considered negative.
obtained using a 25 mm cube sample then, for safety and environmental protection, the first test may be
The tests may be performed in any order. For example, if it is expected that a positive result will be
performed with a 25 mm cube sample. If a positive result is obtained with a 25 mm cube sample then a test
with a 100 mm cube sample is not necessary.
- 364 -

<<<PAGE 7>>>

Copyright © United Nations, 2009. All rights reserved
33.3.1.6.4.2
A substance should not be classified in Division 4.2 if:
(a)
A negative result is obtained in a test using a 100mm cube sample at 140 °C;
(b)
negative result is obtained in a test using a 25 mm cube sample at 140 °C, a negative
A positive result is obtained in a test using a 100mm sample cube at 140 °C and a
result is obtained in a test using a 100mm cube sample at 120 °C and the substance is
to be transported in packages with a volume not more than 3 m°;
(C)
negative result is obtained in a test using a 25 mm cube sample at 140 °C, a negative
A positive result is obtained in a test using a 100 mm sample cube at 140 °C and a
result is obtained in a test using a 100 mm cube sample at 100 °C and the substance is
to be transported in packages with a volume not more than 450 litres.
33.3.1.6.4.3
Packing group Il should be assigned to self-heating substances which give a positive result in
a test using a 25mm sample cube at 140 °C.
33.3.1.6.4.4
Packing group III should be assigned to self-heating substances if:
(a)
negative result is obtained in a test using a 25mm cube sample at 140 °C and the
A positive result is obtained in a test using a 100mm sample cube at 140 °C and a
substance is to be transported in packages with a volume of more than 3 m;
A positive result is obtained in a test using a 100 mm sample cube at 140 °C and a
negative result is obtained in a test using a 25 mm cube sample at 140 °C, a positive
to be transported in packages with a volume of more than 450 litres;
result is obtained in a test using a 100mm cube sample at 120 °C and the substance Is
(c)
A positive result is obtained in a test using a 100 mm sample cube at 140 °C and a
negative result is obtained in a test using a 25mm cube sample at 140 °C and a
positive result is obtained in a test using a 100 mm cube sample at 100 °C.
33.3.1.6.5
Examples of results
Substance
Oven
Cube size
Maximum
Result
temperature
(°C)
(mm)
temperature
reached (°C)
Cobalt/molybdenum catalyst
140
140
100
25
>200
granules
181
P.G. III of 4.2ª
Manganese ethylene bis
(dithiocarbamate) 80% (Maneb)
140
25
> 200
P.G. Il of 4.2
Manganese ethylene bis
(dithiocarbamate) complex
with zinc salt 75% (Mancozeb)
140
25
> 200
P.G. Il of 4.2
Nickel catalyst granules
with 70% hydrogenated oil
140
100
140
Not 4.2
Nickel catalyst granules
140
100
> 200
with 50% white oil
140
25
140
P.G. III of 4.2 a
Nickel/molybdenum catalyst
140
140
100
> 200
granules (spent)
25
150
P.G. III of 4.2ª
Nickel/molybdenum catalyst
granules (passivated)
140
100
161
Not 4.2
Nickel/vanadium catalyst
Granules
140
25
> 200
P.G. II of 4.2
Not tested at 100 °C or 120 °C.
- 365-

<<<PAGE 8>>>

Copyright © United Nations, 2009. All rights reserved
Figure 33.3.1.3.3.1: CLASSIFICATION OF SELF-HEATING SUBSTANCES
NEW SUBSTANCE
the substance undergo
Does
No
dangerous self-heating when tested
in a 100mm sample cube
Yes
the substance undergo
Does
dangerous self-heating when tested
Yes
in a 25 mm sample cube
Packing Group /I*
at 140 °C?
No
the substance undergo
Does
No
dangerous self-heating when tested
in a 100mm sample cube
at 120 °C?
• Yes
the substance undergo
Does
dangerous self-heating when tested
Yes
Packing Group I!I*
in a 100mm sample cube
at 100°C?
- No
→
xempted if transported in package
f not more than 450 litres volum
of not more than 3 cubic metres volume
Exempted if transported in packages
Not a self-heating substance
of Division 4.2
•
*
classified in Division 4.2.
Substances with a temperature for spontaneous combustion higher than 50 °C for 27 m?' should not be
- 361-