# W. R. Grace & Co. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 23-0065
- **title:** W. R. Grace & Co. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2024-04-16
- **effective on:** Not available
- **summary:** 23-0065 response to W. R. Grace & Co. concerning 178.275.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-23-0065.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-23-0065.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-23-0065
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/2024-05/230065.pdf
**body:**

<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
April 16, 2024
1200 New Jersey Avenue, SE
Washington, DC 20590
Mr. Paul Errichetti
Sr. Mgr., Fleet and Dangerous Goods
W. R. Grace & Co.
7500 Grace Drive
Columbia, MD 21044
Reference No. 23-0065
Dear Mr. Errichetti:
This letter is in response to your July 7, 2023, letter requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to pressure relief devices on
specification Department of Transportation (DOT) 51 portable tanks. In your letter, you state that
you have a fleet of DOT 51 portable tanks—comprised of both 250 gallon and 430 gallon
capacities—with a test pressure of 300 psig and a maximum allowable working pressure
(MAWP) of 200 psig. Specifically, you ask whether the required pressure relief devices may
start to discharge at less than 110% of two-thirds of the test pressure.
The answer is no. As provided by § 178.275(g)(6)(ii)—and described in a previous Letter of
Interpretation (LOI) Ref. No. 21-0035—the required pressure relief devices must be set to start
to discharge at a nominal pressure of five-sixths of the test pressure for shells having a test
pressure of not more than 4.5 bar (450 kPa) and 110% of two-thirds of the test pressure for shells
having a test pressure of more than 4.5 bar (450 kPa). Since the applicable portable tanks have a
test pressure of more than 4.5 bar (450 kPa), the start to discharge pressure for the pressure relief
devices is required to be set at 110% of two-thirds of the test pressure (220 psig).
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
Steven W. Andrews Jr.
Acting Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division

<<<PAGE 2>>>

Pollack
23-0065
From: INFOCNTR (PHMSA)
To: Dodd, Alice (PHMSA)
Cc: Hazmat Interps
Subject: FW: LOI for 49 CFR 178.275(g)(6)(ii)
Date: Friday, July 14, 2023 10:56:17 AM
Attachments: DOT-PHSMA LoI 49CFR178.275(g)(6)(ii) - 07Jul2023.pdf
Hi Alice,
Please see the attached interpretation request.
Let us know if you need anything.
Regards,
-Breanna
From: Errichetti, Paul <Paul.Errichetti@grace.com>
Sent: Friday, July 7, 2023 11:11 AM
To: INFOCNTR (PHMSA) <INFOCNTR.INFOCNTR@dot.gov>
Subject: LOI for 49 CFR 178.275(g)(6)(ii)
CAUTION: This email originated from outside of the Department of Transportation (DOT). Do
not click on links or open attachments unless you recognize the sender and know the content
is safe.
Hi,
Please find attached a request for a formal letter of interpretation.
If you have questions with regards to this request please contact me via email or my mobile number
listed below in my signature.
Thanks,
Paul Errichetti | Senior Manager, Fleet & Dangerous Goods
W. R. Grace & Co – Conn. | 7500 Grace Drive, Columbia, MD 21044, USA | T +1 410.531.8215 | M +1
732.306.0683 | paul.errichetti@grace.com
THIS EMAIL AND ANY ATTACHED FILES ARE CONFIDENTIAL AND MAY BE LEGALLY PRIVILEGED. If you are not the addressee, any disclosure,
reproduction, copying, distribution, or use of this communication is strictly prohibited. If you have received this transmission in error please notify the
sender immediately and then delete this email.
Our privacy policy can be found here. At any time, you may change your preferences or remove your data by clicking here. Unsubscribe

<<<PAGE 3>>>

Paul Errichetti
Sr. Mgr., Fleet and Dangerous Goods
T +1 410.531.8215
M +1 732.306.0683
Paul.Errichetti@grace.com
W. R. Grace & Co.-Conn.
7500 Grace Drive
Columbia, MD, USA, 21044
July 7, 2023
Mr. Shane Kelley
Director, Standards and Rulemaking Division
U.S. DOT/PHMSA (PHH-10)
1200 New Jersey Avenue
SE East Building, 2nd Floor
Washington, DC 20590
Dear Mr. Kelley:
I am contacting the agency on behalf of WR Grace with this formal request for a letter of interpretation regarding the Hazardous
Materials Regulations 49 CFR 178.275(g)(6)(ii).
We have a fleet of 250 gallon and 430 gallon DOT 51 portable tanks. The tanks have a test pressure of 300 psig and a maximum
allowable working pressure of 200 psig. Based on the referenced above code, the pressure relief device on these tanks should start to
discharge at 220 psig.
Question: Can we set the pressure relief device on these tanks to start to discharge at 200 psig versus 110% of two-thirds of the test
pressure which noted above would be 220 psig?
If you have any questions or need clarification to my questions, please feel free to contact me by cell phone at (732) 306-0683 or via
email at Paul.Errichetti@grace.com.
Sincerely,
Paul Errichetti
Paul Errichetti
Sr. Mgr., Fleet and Dangerous Goods
1 grace.com