# Manchester Tank — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 98-0564
- **title:** Manchester Tank — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1997-12-31
- **effective on:** Not available
- **summary:** 98-0564 response to Manchester Tank concerning 178.35.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-98-0564.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-98-0564.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-98-0564
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/1998/980564.pdf
**body:**

<<<PAGE 1>>>

•
of Transportation
U.S. Department
Washington, D.C.
400 Seventh Street, S.W.
20590
Research and
Special Programs
Administration
DEC 3 | 1997
Mr. Randy Wahl
Director of Technical Development
Manchester Tank
1749 Mallory Lane #400
Brentwood, TN 37027
Dear Mr. Wahl:
This is in response to your letter requesting clarification of inspection report requirements in
49 CFR 178.35. Specifically, you ask whether your current Inspector's Report is acceptable after
October 1, 1997, since the report currently contains at least the minimum information required in._
the Compresses Gas Association (CGA) Pamphlet C-11.
The answer is yes. Section 178.35(g) specifies that each report must contain, at a minimum, the
applicable information listed in CGA Pamphlet C-11.
I hope this information is helpful. Should you have further questions, do not hesitate to contact
us.
Sincerely,
Hate 2 mitchell
Hattie L. Mitchell, Chief
Exemption and Regulations Termination
Office of Hazardous Materials Standards
..-

<<<PAGE 2>>>

Bette
File: 178.35
SC: 33%,
August 18, 1997
Mr. Edward T. Mazullo
Director of Office of Hazardous Materials Standards
U.S. Department of Transportation
4007* Street S.W.
Washington, D.C. 20590
Dear Mr. Mazullo:
Manchester Tank & Equipment Company would like to request a clarification for
49CFR - Section 178.35 (g).
It is our interpretation that our current Inspector's Report format will be acceptable
atter Uctober 1, 1997, since the report currently contains at least the minimum
information required in CGA Pamphlet C-11. Manchester has put forth considerable
cost and effort towards having custom software written to the current report format
and would like to avoid having the programs being re-written if at all possible.
Manchester Tank would greatly appreciate a written confirmation of our
interpretation for our files.
Thank you.
Sincerely,
Randy Wall fee
Randy Wahl
Director of Technical Development
RW:ms
CC:
Jerry Stockinger
Tom Freeland
MANCHESTER
1749 Mallory Lane, #400, Brentwood, TN 37027 • (615) 370-3833 • Fax (615) 370-6150

<<<PAGE 3>>>

MANCHESTER
(..
1749 Mallory Lane, #400, Brentwood, TN 37027
8 M
DHM-1O
Mr. Edward T. Mazulio
Director of Office of Hazardous Materials
Standards
U.S. Department of Transportation
400 7th Street S.W.
Washington, D.C. 20590
- **truncated:** false