# Ten-E Packaging Services, Inc. — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 99-0054
- **title:** Ten-E Packaging Services, Inc. — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1999-08-10
- **effective on:** Not available
- **summary:** 99-0054 response to Ten-E Packaging Services, Inc. concerning 178.601.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-99-0054.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-99-0054.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-99-0054
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/1999/990054.pdf
**body:**

<<<PAGE 1>>>

of Transportation
U.S.Department
Washington, D.C.
400 Seventh Street, S.W.
20590
Special Programs
Research and
Administration
AUG 1 O 1999
Mr. Robert J. Ten Eyck
Ref. No: 99-0054
Director, Technical Services
Ten-E Packaging Services, Inc.
1666 County Road 74
Newport, Minnesota 55055
Dear Mr. Ten Eyck:
This is in response to your letter of March 1, 1999, requesting clarification on the requirements
for testing packagings under the Hazardous Materials Regulations (HMR; 49 CFR parts 171-
180). Specifically you ask whether each closure for a packaging used under Variation 5 of
§ 172.601(g) must be tested when the periodic design requalification is performed.
The answer is no. Nothing in the HMR requires testing of each different closure used under
Variation 5.
I hope this information is helpful.
Sincerely,
Selm 763l6
Delmer F. Billings
Chief, Standards Development
Office of Hazardous Materials Standards
990054
178.601

<<<PAGE 2>>>

TENOE
3178.601
Setting the standard
99-0054
March 1, 1999
Edward Mazzullo
Office of Hazardous Materials Standards
DHM-10
U.S. DEPARTMENT OF TRANSPORTATION
Research and Special Programs Administration
400 Seventh Street, S.W.
Washington, DC 20590
Dear Ed:
I am writing to request clarification on the use of selective testing provisions for single
packagings found in Section 178.601(g)(5) of Title 49 CFR. Do.the periodic retesting provisions
found in Section 178.601(e) apply to those packagings with different closure devices or gaskets
qualified under the Variation 5 selective testing provisions? For example, a manufacturer
design qualifies a 20 liter, UN 1H1 drum with a 2" pipe threaded plug and then employs
selective testing Variation 5 to qualify alternative closures such as a 2" buttress plug, a crimp-on
closure with pour spout and a friction-fit plug. When the 12 month periodic retest date arrives,
is the manufacturer obligated to evaluate all the closure systems identified above or only the 2"
pipe threaded plug design for which complete design qualification testing was originally
conducted ?
Your clarification on this testing matter is greatly appreciated.
Sincerely,
Robert J. Ten Evck/
Director, Technical Services
TEN-E Packaging Services Inc.
1666 CoUnty Road 74
Hewport. Minnesota 55055
email:info@ten-e.com
NOE
NOH
web:uwo.len-e.com
0671
4591430
ISO 9002