# Printronix — Hazardous Materials Safety Interpretation

- **operation:** document
- **citation:** 99-0318
- **title:** Printronix — Hazardous Materials Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1999-12-17
- **effective on:** Not available
- **summary:** 99-0318 response to Printronix concerning 173.306.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-99-0318.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-99-0318.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-99-0318
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/1999/990318.pdf
**body:**

<<<PAGE 1>>>

U.S. Department
400 Seventh Street, S.W.
of Transportation
Washington, D.C. 20590
Research and
Special Programs
Administration
DEC 1 7 1999
Ms. Kathryn
Parham
Ref. No. 99-0318
Customer Administration
Printronix
14600 Myford Rd
Irvine, CA
92623-9559
Dear Ms. Parham:
This is in response to your letter dated November 19, 1999,
Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180) to
requesting clarification regarding the applicability of the
the transportation of accumulators.
Specifically, you ask if
the HMR apply to replacement accumulators not assembled in
machinery and accumulators transported in
assembled machinery.
As provided by § 173.306 (f) (1), accumulators which are
installed in assembled machinery and constructed with a burst
pressure of at least five times their charged pressure at 70°F
are not subject to the HMR.
Accumulators, as described in
$ 173.306 (f), not in assembled machinery are subject to the
HMR.
However, accumulators intended to function as shock
absorbers, struts, gas spring, pneumatic springs or other
impact or
energy-absorbing devices are not subject to the HMR
provided they meet the criteria specified in S
: 173.306 (f) (4) .
I hope this satisfies your request.
Sincerely,
Transportation Regulations Specialists
Gale
Office of Hazardous Materials Standards
990318
173.306

<<<PAGE 2>>>

PRINTRONIX®
ISO 9000 Registered Worldwide
Irvine, California 92623-9559
14600 Myford Road, P.O. Box 19559
sending
Telephone (714) 368-2300
Mollie
Fax (714) 368-2358
http://www.printronix.com
Apprived
"/16l99.
or
• 11/16/99
Department of Transportation
Al Roberts 30202364-4470
Attention DHM-31
Associate Administrator for Hazardous Materials Safety,
Del Thingle:
research and Specials Programs Administration
Linda
Booth.
United States of America Department of Transportation
Darg. Sm.l (2023664436
Washington, D.C. 20590 ( 202) 3406-7100
REF: D.O.T. Shipping Regulations
Standards
Tech- 202342-4545-Charle
Hockings
i have attached a copy of the current Material Safety Data sheet for shipment of Gas Spring Assy's via
air to several international locations. Please review the attached documentation and advise /
confirm if this product is a dangerous good when:
* 1. Shipped individually as just gas springs to be used for replacement parts.
2. Shipped when installed on a Computer Printer Unit, generally two gas springs per printer.
Please provide a regulatory reference and any exemptions that may be used.
Del Billap
If you require additional information, 1 may be reached at (714) 368-2956.
Please forward all information to:
Standards-
• = .
Printronix Inc.
J
14600 Myford Road
346-8553
Irvine, CA 92606
Attr: Kathryn Parham
(207)
Thank you advance for your time and consideration.
Kathryn Parhar
Printronix Inc.
Export Compliance
- **truncated:** false