# Vermont Department of Public Service — Pipeline Safety Interpretation

- **operation:** document
- **citation:** PI-04-0102
- **title:** Vermont Department of Public Service — Pipeline Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2004-03-24
- **effective on:** Not available
- **summary:** PI-04-0102 response to Vermont Department of Public Service concerning 192.614.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-04-0102.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-04-0102.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-04-0102
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/2004/g04-03-24_Morris_192.614-msfx.pdf
**body:**

<<<PAGE 1>>>

PI-04-0102
U.S. Department of Transportation
Research and Special Programs Administration
400 Seventh St., S.W.
Washington, D.C. 20590
March 24, 2004
Mr. G.C. Morris
Utilities Engineer—Gas
Vermont Department of Public Service
State Office Building, Drawer 20
112 State Street
Montpelier, VT 05620-2601
Dear Mr. Morris:
This is in response to your e-mail of February 25, 2004, in which you request an interpretation of the
provisions of the Federal gas pipeline safety regulations at 49 CFR 192.614, which exclude operators of
certain small gas systems from requirements for a written damage prevention program.
Section 192.614(a) states that "[e]xcept as provided in paragraphs (d) and (e) of this section, each
operator of a buried pipeline must carry out, in accordance with this section, a written program to prevent
damage to that pipeline from excavation activities." Paragraph (d) notes that a damage prevention program
is not required for offshore pipelines and pipelines where physical access is controlled by the operator.
Section 192.614(e) excludes certain small pipelines from some of the damage prevention program
requirements. Section 192.614(e)(1) excludes pipelines operated by persons other than municipalities
(including master meter systems) whose primary activity does not include the transportation of gas from the
requirement to maintain a written damage prevention program. And, § 192.614(e)(2) excludes these
pipelines from the requirements at §§ 192.614(c)(1) and (c)(2) to maintain a list of persons normally engaged
in excavation near the pipeline and to notify persons near the pipeline of the damage prevention program.
It is important to note that master meter systems and other pipelines operated by persons whose
primary activity is not the transportation of gas are only excluded from the requirement to have a written
program in compliance with § 192.614(a). They are NOT excluded from requirements to provide temporary
marking of buried pipelines in the area of excavation (§ 192.614(c)(5)), to provide for actual notification of
persons planning excavations of the temporary marking scheme (§ 192.614(c)(4)), and to provide for
inspection of pipelines near excavations to verify integrity (§ 192.614(c)(6)).
In addition, a gas operator is not excluded from the requirement to have a written damage prevention
program merely because they are owned by a larger company whose primary business in not the
transportation of gas. The pipeline safety regulations apply to the operator of the gas system. Section
192.614(e) (a) is clearly intended to apply to persons operating gas systems as a minor part of their business.
This interpretation of the regulations cannot be altered by general language that may be contained in
guidelines and other publications, including the Training Guide for Operators of Small LP Gas Systems, The
Training Guide for Operators of Small LP Gas Systems, which was sponsored in part by the U.S. Department of
Transportation.
If you have any further questions about the pipeline safety regulations, please contact me at (202)
366-4565.
Sincerely,
Richard D. Huriaux, P.E.

<<<PAGE 2>>>

Manager Regulations
Office of Pipeline Safety

<<<PAGE 3>>>

Huriaux, Richard
From: Huriaux, Richard
Sent: Wednesday, February 25, 2004 3:54 PM
To: 'Morris, GC'
Subject: RE: code interpretation
I received your e-mail and will treat it as a request for an official INTERPRETATION. No promises, but I will try
to have something back to you by the end of next week...
################################
/ Richard D. Huriaux. P.E.
/ Manager, Regulations
/ US DOT / Office of Pipeline Safety
/ 400 7th Street, SW, Room 7128
/ Washington, DC 20590
/ Tel: 202-366-4565 Fax: 202-366-4566
################################
------- Original Message ------------
From: Morris, GC (mailto:GC.Morris@state.vt.us] Sent: Wednesday, February 25, 2004 12:03 PM
To: Huriaux, Richard
Subject: code interpretation
Good afternoon Richard,
Thank you for discussing CFR Title 49, Part 192, earlier this month. As you know, my questions regarded
§192.614, Damage Prevention Program, and the parties required to comply with it.
Paragraphs (a), (d) and (e) of this section exclude operators of certain small gas systems from some
requirements, including a written program to prevent damage to that pipeline from excavation activities. Of
particular concern is the wording "primary activity" in paragraph (e).
(e) Pipelines operated by persons other than municipalities (including operators of master meters) whose
primary activity does not include the transportation of gas need not comply with the following:
(1) The requirement of paragraph (a) of this section that the damage prevention program be written;
and
(2) The requirements of paragraphs (c)(1) and (c)(2) of this section.
During our conversation, you advised me that §192.617(e) addresses the exclusion of non- gas companies
(such as real estate companies and school campuses). Additionally, the code applies to the company operating
the gas system. Ownership of the operating company and what that corporation, or group, does for business is
not of concern.
Would you please produce a written interpretation regarding this issue and forward it to me at your earliest
convenience? Our department would like to be able to utilize the interpretation in future cases, involving
jurisdictional system operators who do not acknowledge responsibility because the system is small or the
organization considers gas operation to be a minor part of their business.
Thanks again for your attention to this matter.
Sincerely,
GC Morris
Utilities Engineer – Gas
Vermont Dept. of Public Service
112 State St
Montpelier, VT 05620-2601
- **truncated:** false