# Pipeline Safety Interpretation PI-09-0015

- **operation:** document
- **citation:** PI-09-0015
- **title:** Pipeline Safety Interpretation PI-09-0015
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2009-08-18
- **effective on:** Not available
- **summary:** PI-09-0015 concerning 192.513, 192.557.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-09-0015.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-09-0015.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-09-0015
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/2009/PI-09-0015.pdf
**body:**

<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
1200 New Jersey Avenue, SE
Washington, D.C. 20590
AUG 1 8 2009
Mr. Paul Cabot
GPTC Secretary
Gas Piping Technology Committee (GPTC)
American Gas Association
400 North Capitol Street, NW
Suite 450
Washington, DC 20001
Dear Mr. Cabot:
In a letter to the Pipeline and Hazardous Materials Safety Administration (PHMSA) dated
October 19,2006, you requested an interpretation of the applicability of the Federal pipeline
safety regulations in 49 CFR Part 192 to plastic natural gas pipelines. Specifically, you
requested an interpretation of 49 CFR §§ 192.513(c), 192.557(c), and 192.619(a)(2)(i) as they
relate to uprating polyethylene (PE) pipelines. You used the example of a 4-inch PE pipeline
with a design pressure rating of 100 psig, tested to 75 psig at the time of construction, with a
maximum allowable operating pressure (MAOP) of 50 psig. You suggested an approach to
uprating such a line to 60 psig in increments without testing the pressure and asked whether your
approach would be permissible under current regulations.
You correctly noted that § 192.557( c) permits uprating a pipeline by increasing line pressure in
increments. You referenced a November 14, 1973, Office of Pipeline Safety interpretation for
steel pipelines that permitted incremental uprating of steel pipelines without a pretest. You
stated your belief that if this interpretation were applied to plastic pipelines, uprating
incrementally in accordance with § 192.557( c) would be acceptable without testing the pressure.
You expressed your view that it would be acceptable to incrementally increase the pressure to the
new MAOP without testing it to 1.5 times the new MAOP.
As the regulatory agency with primary responsibility. for pipeline safety in the U.S., PHMSA is
obligated to ensure the pipeline safety requirements provide an adequate margin of safety. In
carrying out our responsibilities, we appreciate receiving input and views from all stakeholders
and particularly appreciate the views of the GPTC. In this case, however, we can not agree that
the above referenced interpretation can be applied to plastic pipelines. Under § 192.619 the
MAOP requirements for steel and plastic pipelines are not the same. For plastic pipelines
§ 192.619(a)(2)(i) requires the following:
The Pipeline and Hazardous Materials Safety Administration. Otlice of Pipcline Safety provides written clarifications of the
Regulations (49 CFR Parts 190-199) in the form of interpretation letters. These lettcrs reflect the agency's current appl ication of
the regulations to the specific facts presented by the person requesting the clarification. Interpretations do not create legally-
enforceable rights or obligations and are provided to hdp the public understand how to comply with the regulations.

<<<PAGE 2>>>

2
§ 192.619 - (a) Except as provided in paragraph (c) of this section, no person may
operate a segment of steel or plastic pipeline at a pressure that exceeds the lowest
of the following:
(1) ...
(2) The pressure obtained by dividing the pressure to which the segment was
tested after construction as follows:
(i) For plastic pipe in all locations, the test pressure is divided by a factor
of 1.5.
We agree that § 192.557 allows the uprating ofPE pipelines. However, § 192.619 (a)(2)(i)
requires the operator to increase the uprating test pressure to 1.5 times the new MAOP in order to
meet the lowest limiting factor for the new MAOP. Therefore, in order for the operator to
increase the MAOP from 50 psig to 60 psig, a pressure test to 1.5 times the new MAOP (90 psi g)
must be conducted to comply with the § 192.619 (a)(2)(i) requirements. I In addition, other
applicable requirements must be met including:
• Following procedures prior to uprating (§ 192.557(b)(1 »;
• Checking rating of applicable appurtenances for the test pressure; and
• Meeting and maintaining operating conditions to ensure pressure increments as required
by the uprating (§ 192.553(a».
I hope that this information is helpful to you. If I can be of further assistance, please contact me
at (202) 366-4046.
Sincerely,
I Note that § 192.553 was amended on September 15,2003, [68 FR 53895] to make direct reference to § 192.619
and clarify the uprating requirements. This amendment addressed the concern that the previous language referring
to "this part" was potentially being applied differently among the States. This was a key focus of the work done
under the State Industry Regulatory Review Committee (SIRRC) II in recognizing the principal differences between
strength test vs. leak test. The SIRRC II formulated the proposed language to state these would be subjected to
incremental pressure increases to the desired new MAOP with an additional leak survey to be performed no sooner
than 10 days and no later than 30 days after the date the last pressure increase is achieved.
The Pipeline and Hazardous Materials Safety Administration. Office of Pipeline Safety provides written clarifications of the
Regulations (49 CFR Parts 190-199) in the form of interpretation letters. These letters reflect the agency's current application of
the regulations to the specific facts presented by the person requesting the clarification. Interpretations do not create legally-
enforceable rights or obligations and are provided to help the public understand how to comply with the regulations.

<<<PAGE 3>>>

Paul Cabot
GPTC Secretary
(202) 824-7312
Fax (202) 824-9122
pcabot@aga.org
October 19, 2006
Richard D. Huriaux
Manager Regulations
Office of Pipeline Safety (DPS -10), RSPA
U.S. Department of Transportation
400 Seventh Street, SW Room 7128
Washington, DC 20590-001
Re: Uprating plastic pipelines to 100 psi or below does not require additional testing
Dear Mr. Huriaux:
The Gas Piping Technology Committee (GPTC) consists of about 80 members with technical
expertise in natural gas distribution, transmission, and gathering systems. Its membership is
balanced between gas distribution operators, gas transmission operators, manufacturers, and
general interest personnel such as federal and state regulators. The GPTC is an Independent
technical committee and has been an American National Standards Institute (ANSI) accredited
committee since 1992 and has the ANSI committee designation of ANSI/GPTC Z380. The
American Gas Association (AGA) has been the Secretariat to this committee since 1990.
The GPTC respectfully requests an interpretation on the application of several sections of Title
49, Part 192, Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety
Standards, specifically Sections 192.513(c), 192.557(c) and Section 192.619(a)(2)(i) as these
relate to uprating PE pipelines.
Given the example:
A 4" PE pipeline, with a design pressure rating of 100 psig, was initially tested at the time of
construction to 75 psig in accordance with Section 192.513(c). This gave the pipeline an MAOP
of 50 psig as defined in 192.619(a)(2)(i).
Now, going forward, an operator has interest in uprating the above referenced pipeline to a
higher MAOP of 60 psig.
Page 1 of 2

<<<PAGE 4>>>

The new MAOP of 60 psig can be approached and established by increasing line pressure in
increments up to the 60-psig limit. The GPTC considers the above uprating procedure to be
acceptable based on the interpretation of referenced code sections. Further, the GPTC is aware
OPS previously provided a similar interpretation dated November 14, 1973 for steel pipelines
operating below 100 psig. In that interpretation under question 3, OPS stated, "Section
192.557(c) requires only that the new MAOP be approached in increments. In uprating, the
pretest to 90 psig would not be required." This interpretation is attached as a reference.
Therefore, the GPTC respectfully requests OPS to affirm the above interpretation is also
applicable for plastic pipelines operating at 100 psig or below. The affirmation would confirm
that Section 192.557(c) does not require the total pressure increase to be 1.5 times the proposed
MAOP, instead the total pressure would be increased up to the proposed MAOP in increments.
Your prompt consideration would be appreciated.
Sincerely,
Paul Cabot
GPTC Secretary
American Gas Association
cc: Marek
Frantz
Slagle
attachment: 11/14/73 OPS Interpretation
Page 2 of 2

<<<PAGE 5>>>

November 14, 1973
Mr. John Searcy
Tennessee Public Service Commission
Cordell Hull Building
Nashville, TN 37219
Dear Mr. Searcy:
In your letter of October 3, 1973, you requested interpretations of various sections of Part 192, Title 49,
CFR, that related to maximum allowable operating pressures (MAOP), certain test requirements, and
uprating. Your specific questions and the Office of Pipeline Safety (OPS) answers are:
Question 1: Re: Maximum allowable operating pressures
"192.619(a)(2) requires that test pressure values be used as criteria for determining maximum allowable
operating pressures; however, it applies only to steel operating at or above 100 psi and plastic.
"192.621 covers all materials including cast iron and ductile iron; however, it does not require that test
pressure values be used as criteria for determining maximum allowable operating pressures.
"Therefore, I conclude that, for steel operating below 100 psi and for cast iron and ductile iron operating at
any pressure, test pressure valves are not required criteria for determining maximum allowable operating
pressures. Is this your interpretations?"
Questions 2: Re: Test requirements
"192.507(b) provides test requirements for pipelines of all materials operating at or above 100 psi and less
than 30% SMYS and requires test pressure values between 100 psi and those required to produce 20%
SMYS. However, it does not specify what the values will be. 192.619 would determine the test pressure
values within this range for steel and plastic by relating them to maximum allowable operating pressure.
However, 192.619 does not apply to cast iron and ductile iron.
"192.509 covers pipelines of all materials operating at or below 100 psi, and requires 10 psi or 90 psi as
test pressures.
"The conclusion here would be that values of test pressures can be established in any pressure range for
steel and plastic, and for cast iron and ductile iron operating at or below 100 psi; however, there is no
required test pressure value for cast iron and ductile iron operating above 100 psi. Is this the proper
interpretation?"
Answer to Questions 1 & 2
DB
C:\WP51\INTERPRT\192\619\73-11-14.N
1

<<<PAGE 6>>>

Test requirements for pipelines to operate at or below 100 psig is established by Section 192.509 based
upon the intended MAOP and is applicable with the exception of service lines and plastic pipe. Cast iron
and ductile iron pipelines would be included under this section if the intended MAOP is 100 psig or less.
For pipelines to operate at a hoop stress of less than 30 percent SMYS but more than 100 psig, Section
192.507 is applicable, with limitations on the MAOP for steel and plastic pipelines being set by Section
192.619.
Your interpretation is correct. There is no specific test pressure required for cast iron and ductile iron
operating above 100 psig and up to 30 percent of SMYS. However, the operator must comply with the
requirements of Sections 192.507 and 192.53.
Question 3: Re: Uprating
"192.557(c) provides that an increase in maximum allowable operating pressure must be made in
increments. However, the following questions arise:
"(1) If the maximum allowable operating pressure it to be increased within the 1 psi to 100 psi
range, and no test records are available, must it be tested to 90 psi first, in accordance with
192.509, and if so, must the test pressure be approached in the increments specified in
192.557(c)?
"(2) Or, does 192.557(c) require only that the new maximum allowable operating pressure
itself be approached in the increments required?
Answer to Question 3
Section 192.557(c) requires only that the new MAOP be approached in increments. In uprating, the pretest
to 90 psig would not be required.
If we may assist further, please let us know.
Sincerely,
/signed/ Cesar De Leon
Joseph C. Caldwell
Director
Office of Pipeline Safety
DB
C:\WP51\INTERPRT\192\619\73-11-14.N
2
- **truncated:** false
- **body characters:** 12281