# New Mexico Public Regulation Commission — Pipeline Safety Interpretation

- **operation:** document
- **citation:** PI-09-0021
- **title:** New Mexico Public Regulation Commission — Pipeline Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 2009-08-11
- **effective on:** Not available
- **summary:** PI-09-0021 response to New Mexico Public Regulation Commission concerning 192.619.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-09-0021.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-09-0021.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-09-0021
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/2010/PI-09-0021.pdf
**body:**

<<<PAGE 1>>>

U.S. Department 1200 New Jersey Avenue, SE
of Transportation Washington, D.C. 20590
Pipeline and Hazardous
Materials Safety
Administration
AUG 1 1 2010
Mr. Joe M. Johnson
Acting Bureau Chief
New Mexico Public Regulation Commission
Pipeline Safety Bureau
1120 Paseo de Peralta
Santa Fe, New Mexico 87504
Dear Mr. Johnson:
In a letter to the Pipeline and Hazardous Materials Safety Administration (PHMSA) dated
October 19,2009, you requested an opinion/interpretation on the requirements of § 192.619 and
asked whether the current policy of the New Mexico Public Regulation Commission's Pipeline
Safety Bureau (PSB) on determining maximum allowable operating pressure (MAOP) for
intrastate gas pipelines regulated by the PSB is acceptable.
You stated that the PSB had recently performed compliance reviews involving older (pre-1970)
gas pipelines for which the operators were unable to provide operating pressure records for the
five year period preceding July 1, 1970. These operators are suggesting that they do not believe
that they have to comply with the MAOP requirements of § 192.619(a)(3) on the grounds that
the lines are pre-code. You stated that in some cases, this had resulted in those operators
attempting to establish MAOPs of their pre-code pipelines at a pressure higher than the pipeline
had ever been known to operate at without pressure testing or uprating the pipeline.
You correctly stated that under Part 192, gas distribution and transmission pipelines operated
prior to July 1, 1970, that were not pressure tested after July 1, 1965, and for which the operating
pressure for the five years preceding July 1, 1970, cannot be documented, the pipeline would
need to be pressure tested or uprated in order to establish a MAOP for the pipeline. However,
you also stated that for a number of years it has been PSB's alternative practice to:
a) Accept an affidavit from a person responsible for pipeline operations during that time
period, attesting to the operating pressure during that period; or
b) Require the operator to consult with PSB and select a substitute five year period,
acceptable to the PSB in lieu of testing or uprating pre-1970 pipelines in § 192.619( a)(3).
You stated that your internal policy in this regard is as follows:
1) PSB would review available operating records. PSB would choose operating
records dating back as close to the five years preceding July 1, 1970, and would
use operating records for the 1970' s whenever possible;
The Pipeline and Hazardous Materials Safety Administration, Office of Pipeline Safety provides written clarifications of the Regulations (49 CFR
Parts 190-199) in the form of interpretation letters. These letters reflect the agency's current application of the regulations to the specific facts
presented by the person requesting the clarification. Interpretations do not create legally-enforceable rights or obligations and are provided to
help the public understand how to comply with the regulations.

<<<PAGE 2>>>

2
2) PSB would not accept operating records after the date an operator was inspected
or cited for an MAOP violation as a substitute for the period specified in
§ 192.619(a)(3); and
3) If the pipeline operator and PSB cannot agree on a substitute pressure, the
operator is given a reasonable amount oftime to pressure test, uprate, or
otherwise provide adequate documentation to support the intended MAOP.
We agree with PSB that gas distribution and transmission pipelines operated prior to
July 1, 1970, that were not pressure tested after July 1, 1965, and for which operating pressure
for the five years preceding July 1, 1970, cannot be documented, the pipeline would need to be
pressure tested or uprated in order to establish a MAOP for the pipeline in accordance with
Part 192.
Regarding PSB's alternative practice of accepting affidavits or other operating records in lieu of
pressure testing or uprating ofpipelines in the absence of pre-July 1, 1970 pipeline operating
pressure data, we would note that Part 192 has no regulatory language to support the allowance
ofthe PBS alternative practice. In order to establish a MAOP in a manner other than pressure
testing or uprating in accordance with Subpart K of Part 192, an operator would have to seek a
waiver and provide justification for its proposed alternative approach.
I hope that this information is helpful to you. If I can be of further assistance, please contact me
at (202) 366-4046.
Sinc~rely,
" / j/( / / /~ 10
C~///I /;--./J;(
Jo· . ale
. Director, Office of Regulations
/
The Pipeline and Hazardous Materials Safety Administration, Office of Pipeline Safety provides written clarifications of the Regulations
(49 CFR Parts 190-199) in the form of interpretation letters. These letters reflect the agency's current application of the regulations to the
specific facts presented by the person requesting the clarification. Interpretations do not create legally-enforceable rights or obligations and
are provided to help the public understand how to comply with the regulations.

<<<PAGE 3>>>

PHP Controlled Correspondence Sheet
PHMSA Control Number: Action Office: PHP- 30
PHP Control Number: 10-0016 Due Date: 12/28/2009
Writer: Joe M. Johnson
Subject: : New Mexico Public Regulation Commission request an
opinion/interpretation on the requirements of Section 192.619
Action: Opinion/interpretation
Date Action Action by
Date Note Note by
For more information please contact:
Glenda Marshall, Glenda.marshall@dot.gov

<<<PAGE 4>>>

orr 28 2009
NEW MEXICO PUBLIC REGULATION COMMISSION
COMMISSIONERS
DISTRICT 1 JASON MARKS
DISTRICT 2 DAVID W. KING, VICE CHAIRMAN
DISTRICT 3 JEROME D. BLOCK
DISTRICT 4 CAROL K. SLOAN
DISTRICT 5 SANDY JONES, CHAIRMAN
P.O. Box 1269
1 120 Paseo De Peralta Room 409
Santa Fe, NM 87504-1269
Transportation Division Director
Larry L. Lujan
(505) 476-0298 Main Line
(505) 827-4388 Fax
CHIEF OF STAFF
Daniel "Danny" Mayfield
October 19, 2009
Mr. Jeff Wiese, Associate Administrator
US DOT/PHMSA/OPS
PHH-1
1200 New Jersey Avenue, SE
East Bldg., 2nd Floor
Washington, DC 20590
Dear Mr. Wiese:
I am writing to request an opinion/interpretation on the requirements of Section 192.619 and whether
our current policy on determining maximum allowable operating pressures (MAOPs) for pipelines is
acceptable.
Recently we have had a couple of operators of older (pre-code) pipelines who have suggested that for
pipelines operated prior to July 1, 1970, and operating records for the 5 years preceding July 1, 1970 are
not available, that they do not have to comply with the requirements of Section 192.619(a,3). In some
cases this has resulted in those operators attempting to establish MAOPs of their pre-code pipelines at a
pressure higher than the pipeline has ever been known to operate at, without pressure testing or
uprating the pipeline.
In accordance with Section 192.619 What is the maximum allowable operating pressure for steel or
plastic pipelines?, with one exception as provided in paragraph (c) of 192.619, no person may operate a
segment of steel or plastic gas distribution or transmission pipeline at a pressure that exceeds the
lowest of the following:
1
1 888 4 ASK PRe
www.nmprc.state.nm.us

<<<PAGE 5>>>

(1) The design pressure ofthe weakest element in the segment, determined in accordance with
subparts C and D of Part 192.
(2) The pressure obtained by dividing the pressure to which the segment was tested after construction
as specified in paragraph 192.619(a,2}.
(3) The highest actual operating pressure to which the segment was subjected during the 5 years
preceding July 1, 1970, unless the segment was tested according to the requirements in paragraph
192.619(a,2} after July 1, 1965 or the segment was uprated according to the requirements in subpart
K.
(4) The pressure determined by the operator to be the maximum safe pressure after considering the
history ofthe segment, particularly known corrosion and the actual operating pressure.
It is our understanding that for gas distribution and transmission pipelines operated prior to July I, 1970,
that were not pressure tested after July I, 1965, and operating pressure for the 5 years preceding July I,
1970, is unknown the pipeline would need to be pressure tested or uprated in order to establish the
Maximum Allowable Operating Pressure (MAOP) for the pipeline.
However, for a number of years it has been our practice to:
a} Accept an affidavit from a person responsible for pipeline operations during that time period,
attesting to the operating pressure during that period, or
b} The operator must consult with the Pipeline Safety Bureau and may select a substitute 5 year
period, acceptable to the Pipeline Safety Bureau, in lieu of testing or uprating pipelines that
were operated prior to July I, 1970, and the operator cannot document the highest operating
pressure for the 5 years preceding July 1,1970, as specified in Section 192.619(a,3}. Our internal
policy in this regard is as follows:
I} Review available operating records. We will choose operating records dating back as close to
the 5 years preceding July I, 1970, and will try to find operating records for the 1970s, whenever
possible. Those records have a higher probability of reflecting operating pressures for the period
specified in Section 192.619(a,3}.
2} We will not accept operating records after the date an operator was inspected or cited for an
MAOP violation as a substitute for the period specified in 192.619(a,3}.
3} If the pipeline operator and the Pipeline Safety Bureau cannot agree on a substitute pressure,
the operator is given a reasonable amount of time to:
(a) pressure test,
(b) uprate, or
(c) provide adequate documentation to support the intended MAOP.
2

<<<PAGE 6>>>

Is the above policy acceptable as an alternative to pressure testing or uprating, when records needed to
demonstrate compliance with Section 192.619(a,3) are not available.
Sincerely,
~P)J1.~
Joe M. Johnson,
Acting Bureau Chief
3
- **truncated:** false
- **body characters:** 9979