# Department of Housing & Urban Development — Pipeline Safety Interpretation

- **operation:** document
- **citation:** PI-71-0103
- **title:** Department of Housing & Urban Development — Pipeline Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1971-03-08
- **effective on:** Not available
- **summary:** PI-71-0103 response to Department of Housing & Urban Development concerning 192.3.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-71-0103.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-71-0103.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-71-0103
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1971/g71-03-08_Harbin_192.3_Master_Meter-nlmx.pdf
**body:**

<<<PAGE 1>>>

PI-71-0103
March 8, 1971
Mr. Robin H. Harbin
Attorney-Adviser
Department of Housing
& Urban Development
Daniel Bldg., 15 South 20th Street
Birmingham, Alabama 35233
Dear Mr. Harbin:
This is in reply to your letter of February 24, 1971, concerning the applicability of 49 CFR, Part
192 to gas lines owned by a public housing authority of a municipality.
This office considers the mains and service lines downstream from the master meter to be a
distribution system that is subject to the Natural Gas Pipeline Safety Act. The master meter is
analogous to a meter at the city gate, where there are no separate meters for individual users in
the distribution system downstream from the meter at the city gate, and a flat rate is charged.
The municipality, in the case of the housing complex, is an operator under our regulations.
Section 192.3 of the new Federal Minimum Safety Standards defines "operator" as a person
(including a municipality) who engages in the transportation of gas.
Under §192.3 of the regulations, a service line is defined as a distribution line that transports gas
to a customer meter set assembly from a common source of supply. In the usual case involving
individual customer meters, the distribution system is regulated to the outlet side of each
customer meter set assembly. However, where there is no individual customer meter at the point
where the gas is delivered for consumption by the utilization equipment, the Office of Pipeline
Safety applies the regulations up to the point where the customer meter would normally be - i.e.
at the building wall, and the operator has the burden of compliance with the regulations in
assuring a safe condition to this point.
If you have any further questions, do not hesitate to ask.
Sincerely,
Joseph C. Caldwell
Director
Office of Pipeline Safety
192.3 SERVICLI 1
- **truncated:** false