# Florida Gas Company — Pipeline Safety Interpretation

- **operation:** document
- **citation:** PI-71-065
- **title:** Florida Gas Company — Pipeline Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1971-07-14
- **effective on:** Not available
- **summary:** PI-71-065 response to Florida Gas Company concerning 192.365.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-71-065.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-71-065.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-71-065
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1971/PI71065.pdf
**body:**

<<<PAGE 1>>>

Mr. Ray C. Colby
Staff Engineer
Florida Gas Company
P.O. Box 44
Winter Park, Florida 32790
Dear Mr. Colby:
In response to you letter of June 21, 1971, concerning the requirements of Title 49 CFR, Part
192, Subpart H, Section 192.365, Service Lines: Location of valves, we offer the following
background information.
The proposal of rulemaking for Part 192 was developed from the regulations that were in offset in
the various states on August 12, 1968. This as in most states one of the editions of USAS B31.8,
with some states having more stringent requirements in some areas. The requirements of
§192.365 were developed from these sources plus an evaluation of the comments received on the
Notice of Proposed Rulemaking.
In developing §192.365, a valve located at the property line was considered as a possible service
line valve and was considered as acceptable. However, the above-ground valve at the meter set
was also considered appropriate and depending on the circumstances, just as safe. In some cases
the above-ground valve may be safer in that in emergencies the above-ground valve could be
operated by firemen and police with an ordinary wrench while they may not have the necessary T-
wrench to turn off the underground valve. In other cases an above-ground valve may be damaged
or made inaccessible by the circumstances. The many comments that were received on this
subject did not favor one location over the other, but rather considered to know what is the safest
for their situation.
The only change that was made on this paragraph on the final rule compared to the Notice was
the addition of four words in (b) "that, if feasible, is." These words were added since the
comments pointed out that is some cases it was not practical to install the valve outside the
building.
At the present time the Florida Public Service Commission is the only agency in Florida that is
authorized to act in safety regulation and to establish safety requirements for natural gas pipelines
in addition to those that we have established as a minimum.
We hope that this gives you the background you requested. If you have any additional questions,
do not hesitate to ask.
Sincerely,
DB
C:\INTERPRT\192\365\71-07-14
1

<<<PAGE 2>>>

/signed/
Joseph C. Caldwell, Director
DB
C:\INTERPRT\192\365\71-07-14
2
- **truncated:** false
- **body characters:** 2313