# Piedmont Natural Gas Company, Inc — Pipeline Safety Interpretation

- **operation:** document
- **citation:** PI-72-0115
- **title:** Piedmont Natural Gas Company, Inc — Pipeline Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1972-11-10
- **effective on:** Not available
- **summary:** PI-72-0115 response to Piedmont Natural Gas Company, Inc concerning 192.379.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-72-0115.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-72-0115.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-72-0115
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1972/g72-11-10_Cain_192.379-nlmx.pdf
**body:**

<<<PAGE 1>>>

PI-72-0115
November 10, 1972
Mr. H. F. Cain
Measurement Superintendent
Piedmont Natural Gas Company, Inc.
P.O. Box 1968
Charlotte, North Carolina 28201
Dear Mr. Cain:
This is in response to your letter of October 25, 1972, in which you question whether the company practice with regard
to cutting off service remains an acceptable procedure under the recently adopted amendment 192-8 to 40 CFR Part
192.
Under the amendment, Sections 192.379(d) and 192.727(d)(2) now provide for the inactivation of lines by use of a
mechanical device or fitting installed in the service line or in the meter assembly to prevent the flow of gas. Your
practice is to valve off the service cook, break the meter inlet connection, and insert a tin shut off seal in order to
prevent unauthorized use of gas.
The use of a shut off seal or disc is a commonly used method to prevent the flow of gas, and the procedure you have
described is one of the methods we had in mind in adopting this alternative method in the amendment.
Your interpretation of the regulations, which permits the use of the procedure as described, is correct.
Your interest in pipeline safety is appreciated.
Sincerely,
Joseph C. Caldwell
Director
Office of Pipeline Safety

<<<PAGE 2>>>

Piedmont Natural Gas Company, Inc.
4301 Yancey Road
Post Office Box 1968
Charlotte, North Carolina 28201
October 25, 1972
Mr. Joseph C. Caldwell
Director, Office of Pipeline Safety
Department of Transportation
400 Sixth Street SW
Washington, D. C. 20590
Dear Mr. Caldwell:
We have a question in regard to Part 192-8 of Title 49 of the Code of Federal Regulations, which is effective
November 3, 1972.
We refer to Sections 192.379 "New Service Lines Not in Use", Paragraph (b); and 192.727 "Abandonment or
Inactivation of Facilities", Paragraph (d) (2), both of which read as follows:
"A mechanical device or fitting that will prevent the flow of gas must be installed in the service line or in the
meter assembly."
It has been standard practice, in the case of summer cut offs, or cut offs for non-pay, etc., to valve off the service
cock, break the meter inlet connection and insert a tin shut off seal in order to prevent unauthorized use of gas.
Our interpretation of the two sections in question leads us to believe that this would still be an acceptable
procedure under the new regulations.
Please advise if our interpretation of these sections is incorrect.
Very truly yours,
H. F. Cain
Measurement Superintendent