# International Diversified Service Co. — Pipeline Safety Interpretation

- **operation:** document
- **citation:** PI-72-019
- **title:** International Diversified Service Co. — Pipeline Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1972-05-16
- **effective on:** Not available
- **summary:** PI-72-019 response to International Diversified Service Co. concerning 192.453.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-72-019.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-72-019.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-72-019
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1972/PI72019.pdf
**body:**

<<<PAGE 1>>>

Mr. Vincent Goddard
Management & Market Research Div.
International Diversified Service Co.
321 East Second Street
Los Angeles, California 90012
Dear Mr. Goddard:
This will acknowledge receipt of your letter dated April 26, 1972, regarding pipeline coating.
Your specific questions are:
Question #1: Do you have any enforcement provisions of guidelines that would give more
explicit standards?... (on) paragraphs 195.236, 195,238, and the section following 192.451.
Answer: No, we do not have more explicit standards.
Question #2: Are there any specific licenses or test that a foreign company must pass before they
can sell their pipeline coating products in the United States?
Answer: No, the gas pipeline safety regulations do not specify licenses or tests that a foreign
company must pass before they can sell their pipeline coating products in the United States.
Question #3: Do you have any product specification studies that might be of assistance in
determining the salability of a coating product?
Answer: No, we do not have any specification studies.
We are enclosing a copy of the regulations as you requested. If we can be of further assistance,
please let us know.
Sincerely,
/signed/
Joseph C. Caldwell
Director
Office of Pipeline Safety
Enclosure