# Louisiana Gas Service Company — Pipeline Safety Interpretation

- **operation:** document
- **citation:** PI-76-048
- **title:** Louisiana Gas Service Company — Pipeline Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1976-08-12
- **effective on:** Not available
- **summary:** PI-76-048 response to Louisiana Gas Service Company concerning 192.179.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-76-048.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-76-048.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-76-048
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1976/PI76048.pdf
**body:**

<<<PAGE 1>>>

Aug 12, 1976
Mr. D. L. Meriwether
Director of Technical Standards
Louisiana Gas Service Company
P.O. Box 433
Harvey, Louisiana 70058
Dear Mr. Meriwether:
This responds to your letter dated May 10, 1976, requesting an interpretation of Title 49 CFR
Part 192.179(c).
Question: Where valves are installed at a closer interval than those as specified in 192.179(a),
must a blowdown be installed between each set of valves?
Answer: Yes, Section 192.179(c) states: "Each section of a transmission line, other than offshore
segments, between main line valves must have a blowdown valve with enough capacity to allow
the transmission line to be blown down as rapidly as practicable. Each blowdown discharge must
be located so the gas can be blown to the atmosphere without hazard and, if the transmission line
is adjacent to an overhead electric line, so that the gas is directed away from the electrical
conductors."
The purpose of the pipeline blowdown valves are for exhausting gas from the line when required
by repairs, emergencies, or other conditions.
Question: Is there a guideline that determines the blowdown capacity for a certain size and length
of pipeline?
Answer: Guidelines to determine blowdown capacity are not a function of this Office. Because
the issuing gas jet from a blowdown valve produces a violent reaction thrust, proper blowdown
design is of major importance and is the responsibility of the operator. Blowdown valve sizes
may be selected by using various applicable formula and/or charts that are provided in handbooks
such as the Gas Engineer's Handbook, or from valve manufacturers' literature.
We trust that this adequately responds to your inquiry.
Sincerely,
Cesar DeLeon
Acting Director
dal\192\179\76-08-12
1

<<<PAGE 2>>>

Office of Pipeline
Safety Operations
May 10, 1976
Department of Transportation
Materials Transportation Bureau
Office of Pipeline Safety Operations
400 7th Street S.W.
Washington, D.C. 20590
Gentlemen:
We would like to have an interpretation regarding Part 192.179(c) of Title 49 of the Code of
Federal Regulations.
Where valves are installed at a closer interval than those as specified in 192.179(a), must a
blowdown be installed between each set of valves? Rule 192.179(c) also states that the
blowdown valve must have a capacity to allow the transmission line to be blown down as rapidly
as practicable. Is there a guideline that determines the blowdown capacity for a certain size and
length of pipeline?
At your convenience, we would appreciate an interpretation of this regulation.
Yours very truly,
LOUISIANA GAS SERVICE COMPANY
D. L. Meriwether
Director of Technical Standards
dal\192\179\76-08-12
2

<<<PAGE 3>>>

dal\192\179\76-08-12
- **truncated:** false
- **body characters:** 2711