# Metallurgical Consultants, Inc. — Pipeline Safety Interpretation

- **operation:** document
- **citation:** PI-77-008
- **title:** Metallurgical Consultants, Inc. — Pipeline Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1977-02-14
- **effective on:** Not available
- **summary:** PI-77-008 response to Metallurgical Consultants, Inc. concerning 195.1.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-77-008.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-77-008.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-77-008
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1977/PI77008.pdf
**body:**

<<<PAGE 1>>>

February 14, 1977
Answer: Mr. T. V. Bruno
Metallurgical Consultants, Inc.
P.O. Box 88046
Houston, TX 77004
Dear Mr. Bruno:
This is in reply to your letter of July 30, 1976, requesting an
interpretation of the requirements of 49 CFR Part 195,
"Transportation of Liquids by Pipeline," relating to the length
of allowable internal undercutting of pipeline welds.
Question: What is the limit of any individual length of
undercutting?
Question: Is there a limit of length of undercutting in any given
continuous length of weld (e.g., 12 inches, 1/6 the
total weld length, 8 percent of the total weld length)
and if so, what is the limit?
In regard to the above two questions, Part 195 has
incorporated by reference API Standard 1104 for standards of
acceptability for welding. Subsection 6.9, Undercutting, of that
standard prescribes the limits of undercut. As stated in that
standard, where depth of undercut is between 1/64 inch and 1/32
inch, the length of any continuous undercut should not exceed 2
inches or 1/6 the length of the specific weld, whichever is
smaller.
Answer: Consultation with Mr. R. B. Gwinn, Secretary, API-AGA
Joint Committee on Oil and Gas Pipe Line Field Welding
Practices, had indicated that this requirement as
specified in the 13th edition of API Standard 1104 is
in error. Mr. Gwinn has advised that this matter would
be corrected in the 14th edition soon to be published
and that for undercut depth between 1/64 inch and 1/32
inch the limitation for undercutting length will be 2
inches in a continuous weld length of 12 inches or 1/6
of the length, whichever is smaller.
Question: Does Subsection 6.8 of API Standard 1104 include
undercutting in determining accumulation of
discontinuities?
The intent of Subsection 6.8 of API Standard 1104 is
not only to exclude high-low condition but also undercutting in
determining accumulation of discontinuities. We have been
advised that API will also revise this section in the 14th
edition of 1104 to clarify this intent.
dal\195\0\77-02-14
1

<<<PAGE 2>>>

Upon receipt of this new edition, OPSO will analyze its
content and proceed to determine if it is appropriate
for incorporation by reference in OPSO's regulations.
I trust that this adequately responds to your inquiry.
Sincerely,
Cesar DeLeon
Acting Director
Office of Pipeline
Safety Operations
dal\195\0\77-02-14
2

<<<PAGE 3>>>

July 30, 1976
Ref: 476-76-2303
Subj: Interpretation of
49CFR195
Mr. Cesar DeLeon
Office of Pipeline Safety Operations
Department of Transportation
Materials Transportation Bureau
Washington, D.C. 20590
Dear Mr. DeLeon:
The purpose of this letter is t o request an official
interpretation of the requirements of 49 CFR Part 195 relating to
the length of allowable internal undercutting of pipeline girth
welds.
As revised on October 1, 1975, paragraph 195.228
applies the standards of acceptability of subsection 6.9 of the
1973 edition of API Standard 1104 to undercutting only if the
undercutting is measured visually on each girth weld of the same
diameter. There is no specific statement concerning what
standards apply if undercutting is not measured visually.
If undercutting is measured only by radiography, I
presume the only criterion of acceptability is length of
undercutting. Subsection 6.9 of the 1971 edition of API Standard
1104 states:
"Undercutting adjacent to the root bead on the inside
of the pipe shall not exceed 2 in. in length, or 1/6 of
the length of the weld, whichever is smaller."
At least two interpretations have been applied to this statement.
One interpretation is that it limits the accumulated length of
all undercutting to 2 inches or 1/6 the length of the weld,
whichever is smaller; the other is that it limits any individual
occurrence of undercutting to 2 inches or 1/6 the length of the
weld with no limit on accumulated length.
Another subsection of API Standard 1104 that may relate
to undercutting, subsection 6.8, is also subject to more than one
interpretation. Subsection 6.8 is the same in both the 1971 and
1973 editions of API Standard 1104 and states:
"Excluding high-low condition, any accumulation of
discontinuities having a total length of more than 2
in. in a continuous weld length of 12-in. or more than
8 percent of a continuous weld length if the total weld
dal\195\0\77-02-14
3

<<<PAGE 4>>>

length is less than 12-in. is unacceptable. Any
- 2 -
accumulation of discontinuities which total more than 8
percent of the weld length associated with an entire
joint is unacceptable."
Some people have interpreted this statement as including
undercutting in determining the allowable length of accumulated
discontinuities. Others, however, have reasoned that since the
subsection on undercutting, (6.9), apparently was deliberately
placed after the subsection on accumulation of discontinuities,
(6.8), while subsections covering other discontinuities were
placed before it, the subsection on accumulation of
discontinuities was not intended to apply to undercutting.
In view of the above considerations, I would appreciate
an official interpretation from OPSO of the requirements of 49
CFR 195 pertaining to allowable length of undercutting determined
by radiography, specifically:
1. What is the limit of any individual length of
undercutting?
2. Is there a limit of length of undercutting in any
given continuous length of weld
(e.g. 12 inches, 1/6 the total weld length, 8
percent of the total weld length) and if so, what
is the limit?
3. Does subsection 6.8 of API Standard 1104 include
undercutting in determining accumulation of discontinuities?
We are currently involved in several pipeline pro jects
that must meet federal requirements and would appreciate an early
reply.
Very truly yours,
T. V. Bruno
dal\195\0\77-02-14
4
- **truncated:** false
- **body characters:** 5763