# Williams Brothers Engineering Company — Pipeline Safety Interpretation

- **operation:** document
- **citation:** PI-77-017
- **title:** Williams Brothers Engineering Company — Pipeline Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1977-07-05
- **effective on:** Not available
- **summary:** PI-77-017 response to Williams Brothers Engineering Company concerning 192.5.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-77-017.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-77-017.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-77-017
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1977/PI77017.pdf
**body:**

<<<PAGE 1>>>

Jul 5 1977
Mr. Leo R. Kenyon
Williams Brothers Engineering Company
6600 S. Yale Avenue
Tulsa, Oklahoma 74136
Dear Mr. Kenyon:
This is in response to your letter of February 25, 1977, in which you requested our definition and
advice on three questions concerning Section 192.5 of the Code of Federal Regulations. The
following information is furnished in answer to your questions:
a. A discussion of the reasons for determining 10 or less buildings for Class 1 location and
46 or less buildings for Class 2 location are contained in Notice 70-4, Docket No. OPS-
3D (enclosed). The study which formed the basis for these determinations is also
enclosed.
b. "Normal use" is interpreted to mean the activity that is ordinarily engaged in on the
premises. The frequency of normal use is a factor to consider in determining whether the
use of a building or outside area creates a risk which is similar enough to the risk to the
areas mentioned in §192.5(d)(2)(ii) to warrant application of Class 3 standards.
c Intended for "human occupancy" is interpreted to mean that the building concerned is used
for a purpose involving the presence of humans.
Enclosed are copies of the Office of Pipeline Safety Operations' Advisory Bulletin, Nos. 71-4, 73-
11, 75-4, and 76-11, which contain interpretations of specific examples which may be of
assistance.
If we can be of further assistance, please let me know.
Sincerely,
Cesar DeLeon
Acting Director
Office of Pipeline
Safety Operations
dal\192.1-a\5\77-07-05
1

<<<PAGE 2>>>

February 25, 1977
Department of Transportation
Office of Pipeline Safety Operations
400 Seventh Street, S.W.
Washington, D.C. 20024
ATTENTION: Director
Dear Gentlemen:
We have been requested by our client in Australia to seek your definition and advice on the
following which pertain to DOT regulations 192.5, class locations:
a. Basis for the number of buildings for class 1 and class 2 locations. How were the numbers
10 or less buildings for class 1 and 46 or less buildings for class 2 locations arrived at?
b. What is the interpretation of "normal use" as used in defining class locations? What
frequency of use of a building or defined outside area by more than 20 people would
require the location to be classified 3; once a day, week, month, year?
c. What is the interpretation of "Intended for Human Occupancy" as used in 192.5?
Our Australia client is assisting with revisions to the Australia Pipeline Code and wishes to use the
interpretation and advice of your office on the above questions.
We would be grateful of any assistance you could provide.
Very truly yours,
WILLIAMS BROTHERS ENGINEERING COMPANY
Leo R. Kenyon
dal\192.1-a\5\77-07-05
2
- **truncated:** false
- **body characters:** 2686