{"operation":"document","citation":"PI-79-0104","title":"Pipeline Safety Interpretation PI-79-0104","source_type":"guidance","agency":"Pipeline and Hazardous Materials Safety Administration","status":"guidance","official":true,"published_on":"1979-11-15","effective_on":null,"summary":"PI-79-0104 concerning 192.455.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-interpretation-pi-79-0104.json","markdown":"https://regulus.evalyn.ai/document/phmsa-interpretation-pi-79-0104.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-interpretation-pi-79-0104","source_url":"https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1979/g79-11-15_Powell_192.455-nlmx.pdf","body":"<<<PAGE 1>>>\n\nPI-79-0104\nNovember 15, 1979\nMr. Ronald T. Powell\nR.D. #1, Box 69-A\nBolivar, PA 15923\nDear Mr. Powell:\nYour letter of August 30, 1979, asks five specific questions concerning the requirements for monitoring external\ncorrosion control of gas pipelines under 49 CFR 192.465. Your questions and the MTB responses are as follows:\nQuestion 1: Section 192.465 (a) – What does the DOT mean by survey of a minimum of 10% each year for\nshort service lines and mains, and is this required to be done? If so, does this mean an electrical pipe to soil survey?\nMTB Response : Section 192.465(a) requires all pipelines under cathodic protection to be tested at least once each\ncalendar year to determine compliance with §192.463. An exception is provided for service lines and short sections of\nprotected mains 100 feet or less in length, permitting these to be tested on a sampling basis. The sampling of these\nshort sections must be done in a manner that at least 10% of the total number of such short piping segments in the\npipeline system are tested each calendar year. Failure to conduct these tests in accordance with the required schedule\nis a violation of this section. The tests required must determine whether the cathodic protection requirements of\n§192.463 are being met. Section 192.463 states that the applicable criteria for such tests are contained in Appendix D of\nPart 192. In a telephone conversation with a member of the MTB staff, it was determined that the question assumes\nsteel pipelines. Referring to Appendix D, it is clear that all of the tests mentioned for use on steel pipelines are electrical\ntests.\nQuestion 2: Section 192.465(c)-Concerning two month bonds, I have been led to believe that the two month\ninterval only has to be adhered to where a foreign structure would jeopardize our lines. My question, what about\ninsulated flanges, valves, or any interference from our own crossings on rectified lines requiring a bond with current\nflow? Should this not also be included on a two month interval read since it would jeopardize our own structures?\nWhat is meant by other interference bonds that are checked at least once each calendar year but not exceeding 15\nmonths?\nMTB Response: Section 192.465(c) sets requirements for monitoring the effectiveness of equipment installed to prevent\ndamage due to stray currents. Section 192.473(a) requires each operator to minimize the effects of stray currents on its\npipeline and (b) to minimize the effects of stray currents from its cathodic protection system on existing adjacent\nunderground metallic structures. No mention is made of ownership of these structures. Thus, if stray currents from a\npipeline cathodic protection system is causing damage to another underground metallic pipeline system (owned by the\nsame operator or others), the operator must minimize the detrimental effects of such currents.\n“Other interference bonds” as referred to in §192.465(c) are those bonds whose failure would not jeopardize structure\nprotection.\nQuestion 3: We have several hundred gas meters on rectified transmission pipelines. In many cases, the\nrectifiers are damaging the service lines of consumers. Who is obligated to monitor and/or correct any corrosive\nsituations cause by rectifier interference? Most of these service lines are owned by the consumer who has very little\nknowledge of what is going on.\nMTB Response: We assume that the lines involved are located downstream from the meters you mentioned and that\n\n<<<PAGE 2>>>\n\nthese meters are customer meters. In this case, under the definition of “service line” in §192.3, you would be\nresponsible for the lines if you own them. Customer owned lines lying downstream from the meters are outside the\nscope of Part 192, and you would not be responsible under the regulations to protect them against corrosion. However,\n§192.473(b) requires both impressed current and galvanic anode cathodic protection systems to be designed and\ninstalled so as to minimize any adverse effects on existing adjacent underground metallic structures. Where an adverse\neffect is determined to exist on an adjacent underground structure, §192.473(b) would require corrective action. In\naddition, you may have some other legal responsibility for the damage done by your rectifiers.\nQuestion 4: What time frame does a company have to start the above?\nMTB Response: Compliance with a given requirement is mandatory on and after the effective date. Section 192.465\nbecame effective on August 1, 1971, and §192.473 on July 31, 1973. Regarding question 3, service lines subject to Part\n192 installed after July 31, 1971, must have had a cathodic protection system in place within 1 year after the line was\ninstalled (§192.455). Under §192.457, other service lines were required to be electrically surveyed for areas of active\ncorrosion and cathodically protected in those areas by August 1, 1976.\nQuestion 5: What penalties might be imposed upon a company for violation of DOT requirements described\nabove?\nMTB Response: The Natural Gas Pipeline Safety Act of 1968 (49 U.S.C.1671 et seq.) permits MTB to impose civil penalties\nof up to $1,000 per day per violation, except that the maximum civil penalty shall not exceed $200,000 for any related\nseries of violation.\nThank you for your interest in pipeline safety.\nSincerely,\nCesar DeLeon\nAssociate Director for\nPipeline Safety Regulation\nMaterials Transportation Bureau\n\n<<<PAGE 3>>>\n\nMr. Ronald T. Powell\nR.D. #1, Box 69-A\nBolivar, Pa. 15923\nAugust 30, 1979\nMr. Caesar D. E. Leon DMT-30\nAssociate Director for Office of Pipe Line Safety\nMaterial Transfer, Dept. of Transportation\nWashington, D. C. 20590\nDear Sir:\nI recently talked with Mr. Paul Croy of your department concerning some interpretations of the Federal requirements\npertaining to the \"Natural Gas Pipe Line Industry\". I am requesting a written interpretation of parts of D. O. T.\nrequirements for corrosion control as follows from 192.465, Federal Register, Vol. 36, No. 126:\n1. 192.465 (a) - What does the D. O. T. mean by survey of a minimum of 10% each year for short service\nlines and mains, and is this required to be done. If so, does this mean an electrical pipe to soil survey?\n2. 192-465 (c) - Concerning two month bonds, I have been led to believe that the two month interval only\nhas to be adhered to where a foreign structure would jeopardize our lines. My question, what about\ninsulated flanges, valves, or any interference from our own crossings on rectified lines requiring a bond\nwith current flow. Should this not also be included on a two month interval read since it would\njeopardize our own structures. What is meant by other interference bonds that are checked at least\nonce each calendar year but not exceeding 15 months.\n3. I am not sure to what sections this question would refer to. - We have several hundred gas meters on\nrectified transmission pipe lines. In many cases the rectifiers are damaging the service lines of\nconsumers. Who is obligated to monitor and/or correct any corrosive situations caused by rectifier\ninterference. Most of these service lines are owned by the consumer who has very little knowledge of\nwhat is going on.\nWhat time frame does a company have to start the above?\nWhat penalties might be imposed upon a company for violation of D.O.T. requirements described above?\nIf necessary, would it be possible to have a representative from D. 0. T. come to Pittsburgh to explain this to a company?\nWould you please send an up-to-date copy of \"Subpart I - Requirements for Corrosion Control, Federal Register Vol. 36,\nNo. 126\" as my copy is dated 6/30/71.\nThanking you in advance for your prompt reply.\nVery truly yours,\nRonald T. Powell","truncated":false,"body_characters":7699}