# Memo: Internal — Pipeline Safety Interpretation

- **operation:** document
- **citation:** PI-80-020
- **title:** Memo: Internal — Pipeline Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1980-12-01
- **effective on:** Not available
- **summary:** PI-80-020 response to Memo: Internal concerning 195.304.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-80-020.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-80-020.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-80-020
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1980/PI80020.pdf
**body:**

<<<PAGE 1>>>

Subject: ACTION: Relocation of Pump
From:Melvin A. Judah
Acting Associate Director for Pipeline Safety
Regulation, DMT-30
To: DMT-14
Your memorandum dated June 20, 1980, requested
clarification of Section 195.304(b) concerning removal
of a pump from a pipeline and subsequent use of that
pump on the same pipeline or another pipeline. You
questioned whether the pump must be hydrostatically
tested before being returned to service.
Attached is an interpretation of Section 195.304(b)
Which I hope will be helpful.
Attachment
DB
C:\WP51\INTERPRT\195\304\80-12-01
1

<<<PAGE 2>>>

No. 80-16
Date:December 1, 1980
DEPARTMENT OF TRANSPORTATION
RESEARCH AND SPECIAL PROGRAMS ADMINISTRATION
MATERIALS TRANSPORTATION BUREAU
_________________________________________________________________
PIPELINE SAFETY REGULATORY INTERPRETATION
_________________________________________________________________No
te:A pipeline safety regulatory interpretation applies a particular
rule to a particular set of facts and circumstances, and, as such,
may be relied upon only by those persons to whom the interpretation
is specifically addressed.
SECTION: Section 195.304(b)
SUBJECT: Relocation of Pump
FACTS: A pump, which has been in service at one location on a
pipeline system, is removed from service at that
location, is overhauled and inspected, and is installed
at another location on the same pipeline or another
pipeline. The pump with related piping is the only item
being installed. The pump was originally tested at the
factory.
Questions:Must the pump be hydrostatically tested before being
placed in service if the pump is (1) installed at
another location on the same pipeline system, or
(2) installed on another pipeline system?
Interpretation:Section 195.304(b) excepts a component from the
hydrostatic testing requirement of Section
195.302 if the component is the only item
DB
C:\WP51\INTERPRT\195\304\80-12-01
2

<<<PAGE 3>>>

being replaced or added to a pipeline system
and the manufacturer certifies that the
component was hydrostatically tested at the
factory or that a quality control system was
used to ensure the strength of the component.
In case (1) the pump is being added to the
same pipeline system at another location, and
in case (2) the pump is being added to another
pipeline system. Further, in both cases, the
pump has been hydrostatically tested at the
factory. Therefore, in accordance with
Section 195.304(b), if the appropriate
manufacturer's certification has been made,
the pump need not again be hydrostatically
tested in either case.
The piping installed does not affect the
application of Section 195.304(b) provided it
is the auxiliary piping normally associated
with pump installations and thus does not
remove the installation from the concept that
only a single component is being replaced or
added. However, if the piping were pump
suction and discharge lines with associated
valved and by-pass, more than a single
DB
C:\WP51\INTERPRT\195\304\80-12-01
3

<<<PAGE 4>>>

component would be involved in the
installation and Section 295.304(b) would not
apply.
The fact that the pump was overhauled does not
alter this interpretation as long as the
overhaul involved only those items which
normally wear on pumps, such as bearings,
seals and impeller. If, however, welding or
other repair work that could affect the
strength of the pump case was performed, then
a manufacturer's certification regarding
original testing could not be relied on to
predict future strength, and Section
195.304(b) would not apply.
Melvin A. Judah
Acting Associate Director for
Pipeline Safety Regulation
Materials Transportation Bureau
DB
C:\WP51\INTERPRT\195\304\80-12-01
4
- **truncated:** false
- **body characters:** 3693