# OOE — Pipeline Safety Interpretation

- **operation:** document
- **citation:** PI-81-012
- **title:** OOE — Pipeline Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1981-06-17
- **effective on:** Not available
- **summary:** PI-81-012 response to OOE concerning 195.406.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-81-012.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-81-012.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-81-012
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1981/PI81012.pdf
**body:**

<<<PAGE 1>>>

June 17, 1981
Operator Design of Valves
Signed
Melvin A. Judah
Acting Associate Director, OPSR
Bob Paullin
Associate Director, OOE
The attached interpretation responds to your memorandum of March
17, 1981, regarding the meaning of ?195.406.
Attachment
DB
C:\WP51\INTERPRT\195\406\81-06-17
1

<<<PAGE 2>>>

No. 81-3
Date: June 17, 1981
DEPARTMENT OF TRANSPORTATION
RESEARCH AND SPECIAL PROGRAMS ADMINISTRATION
MATERIALS TRANSPORTATION BUREAU
_________________________________________________________________
PIPELINE SAFETY REGULATORY INTERPRETATION
_________________________________________________________________No
te:A pipeline safety regulatory interpretation applies a particular
rule to a particular set of facts and circumstances, and, as such,
may be relied upon only by those persons to whom the interpretation
is specifically addressed.
SECTION: ?195.406
SUBJECT: Maximum Operating Pressure of Valves
QUESTION 1.a: For Section 195.406(a)(2), who is responsible for
determining the maximum design pressure of components (valves,
flanges, fittings, etc.) of a pipeline, the manufacturers of the
components, or the pipeline operators?
ANSWER: Part 195 applies to the transportation of hazardous
liquids by pipeline in interstate or foreign commerce. (?195.1)
The persons who own or operate the pipelines subject to Part 195
("pipeline operators") are responsible for compliance with the
requirements of Part 195 (?195.10 and 49 U.S.C. 2006). Since the
term "pipeline" includes "component" (?195.2), pipeline operators
must comply with Part 195 provisions governing design pressure of
components. A manufacturer of a component normally does not own or
operate the component after it is put into service subject to Part
195.
QUESTION 1.b: Does this paragraph allow pipeline operators to act
as designers, and by their own calculations or testing, determine
that it is safe to exceed the pressure ratings established by the
actual designer-manufacturer of the component?
ANSWER: The design pressure of components is not prescribed in
specific terms as it is for pipe under ?195.106. However, a few
general requirements apply: for valves, "The valve must be of sound
engineering design." (?195.116(a)); for fittings, "The fitting
must be . . .at least as strong as the pipe . . . ." (?195.118(c));
and for flanges, "[A] flange connection . . . must be suitable for
DB
C:\WP51\INTERPRT\195\406\81-06-17
2

<<<PAGE 3>>>

the service in which it is to be used." (?195.126)
These design requirements do not limit the design of a component to
the manufacturer's pressure rating. There is no express
limitation, and neither the history of Part 195 nor the ordinary
usage of terms would support a finding that the pressure rating set
by a manufacturer is an implied limitation of the quoted design
provisions. Although sound design principles may require that a
manufacturer's pressure rating and applicable factors in consensus
standards be considered in determining the design pressure of a
component, a pipeline operator is free under Part 195 to use
equally sound principles to derive an independent design pressure.
To rule otherwise would allow operators to avoid responsibility
for improper design in cases where a manufacturer's rating is
unsafe, and in cases where a manufacturer's rating is conservative,
give an unfair advantage (and perhaps unlawful power) to
manufacturers.
The preamble to the final rule adopted in ?195.406(a) supports this
conclusion. (35 FR 17184) Under the caption "Section 195.406," the
preamble states, "The design pressure criteria are based on the
definition of maximum operating pressure proposed in the notice."
The definition proposed was: "'Maximum operating pressure' means a
pressure not more than the 'internal design pressure' that is the
maximum pressure established by the carrier (emphasis added) for
the safe operation of a pipeline. . . ." (33 FR 10213) Thus, the
intent of ?195.406(a)(2) was to allow the pipeline operator to
determine design pressure.
QUESTION 1.c: Before an operator exceeds the manufacturer's
maximum working pressure rating of a valve or flange, is it
necessary that MTB review the operator's calculations, i.e., is it
necessary for an operator to apply for a waiver?
ANSWER: Part 195 does not require that an operator seek or
obtain an approval from MTB before placing in operation a pipeline
the operator has designed. Therefore, there is no requirement to
waive. MTB field personnel may choose to verify an operator's
design before a pipeline is placed in operation as a step in the
enforcement process.
QUESTION 1.d: If it is allowable for operators to exceed the
maximum working pressure rating established by its manufacturer,
what specific test or calculations contained in the documents
incorporated by reference in Part 195 are allowable to prove that
flanges and valves can be safely operated in excess of the
manufacturer's rating?
ANSWER: Part 195 does not require the use of referenced
DB
C:\WP51\INTERPRT\195\406\81-06-17
3

<<<PAGE 4>>>

documents to comply with the design requirements for components set
forth in answer to Question 1.b above. The appropriateness of
particular tests or calculations to determine a safe design above a
manufacturer's rating would be judged by sound engineering
principles and practices. Inclusion of particular principles or
practices in a generally recognized consensus standard, regardless
of whether the document is referenced in Part 195, would be a heavy
factor to weigh in making a judgment about the appropriateness of
an operator's tests or calculations.
QUESTION 2: For Section 195.406(a)(4), does this paragraph
allow the operating pressure of valves to be 80 percent of the
factory test pressure or the prototype test pressure? The ANSI
rating is lower than 80 percent of a prototype pressure test on a
valve.
ANSWER: Section 195.406(a)(4) provides one of four criteria, the
lowest value of which determines the maximum operating pressure of
a pipeline. Thus, a valve excepted under ?195.304 could be
operated at 80 percent of its actual or prototype factory test
pressure, provided that pressure does not exceed any of the
pressures determined by the other three criteria. The lower ANSI
rating would not be a consideration in determining compliance with
?195.406(a) unless the ANSI rating were used as the design pressure
under ?195.406(a)(2).
QUESTION 3: For Section 203(d) of the Hazardous Liquid Pipeline
Safety Act, will the "grandfather" provision of the HLPSA exempt
valves installed prior to the adoption of Part 195 from the
requirements of Part 195, including Section 195.406?
ANSWER: The "grandfather" provision of the HLPSA is set forth in
Section 203(c). It reads: "Any standard issued under this section
affecting the design, installation, construction, initial
inspection, and initial testing shall not be applicable to pipeline
facilities in existence on the date such standard is adopted."
This provision, together with the savings provision of Section
218(a) of the HLPSA, would prohibit the application of design and
construction standards to valves in existence before Part 195 was
adopted. Such valves would not be exempt from compliance with
?195.406, however, since this section is an operating rule that
does not fall under the "grandfather" provision.
Melvin A. Judah
Acting Associate Director
for Pipeline Safety Regulation
Materials Transportation Bureau
DB
C:\WP51\INTERPRT\195\406\81-06-17
4

<<<PAGE 5>>>

C:WP51INTERPRT11951406181-06-17
5

<<<PAGE 6>>>

March 17, 1981
Subject: ACTION: Request for Interpretation
Section 195.406(a)(2) & (4)
From:Robert L. Paullin
Associate Director for Operations & Enforcement, DMT-10
To: Melvin A Judah
Acting Associate Director for
Pipeline Safety Regulation, DMT-30
A number of liquid pipeline operators have components
(valves, flanges, and fittings) installed in pipelines
which operate at pressures exceeding the maximum working
pressure specified by the ANSI class rating, or maximum
working pressure marked on the component by its
manufacturer. The pipelines have been operating at
pressures exceeding the components maximum working
pressure rating, which was established by its
manufacturer, since before Part 195 became effective.
These operators feel they are not in violation of
Section 195.406, however, compliance actions have been
initiated by OOE. In order for these compliance cases
to be concluded in a timely manner, we need a prompt
response to the questions included in this memo. Your
cooperation in expediting this request would be
appreciated.
The operator's support for their position is based on
the following rationale:
By using formulas and testing procedures contained in
standards incorporated by reference in Part 195, these
operators have acted as designers and have justified to
their own satisfaction that the components can be safely
operated at pressures exceeding the manufacturer's
maximum working pressure rating. The operators have not
physically changed the manufacturer's design of the
components but have relied solely on their own tests or
calculations to justify the increase in the maximum
pressure rating. For examples of operator justification
of their action see Appendix A.
The OOE contends that the design pressure referenced in
Section 195.406(a)(2) is the pressure established by the
manufacturer of the valve and that Section 195.406(a)(4)
applies to components that otherwise do not have a
standard specification under which they were
DB
C:\WP51\INTERPRT\195\406\81-06-17
6

<<<PAGE 7>>>

manufactured.
In order to determine the enforceability of this
regulation, OOE needs to have OPSR answer the following
questions.
1. For Section 195.406(a)(2):
a. Who is responsible for determining the maximum
design pressure of components (valves,
flanges, fittings, etc.) of a pipeline, the
manufacturers of the components, or the
pipeline operators?
b. Does this paragraph allow pipeline operators
to act as designers, and by their own
calculations or testing, determine that it is
safe to exceed the pressure ratings
established by the actual designer-
manufacturer of the component?
c. Before an operator exceeds the manufacturer's
maximum working pressure rating of a valve or
flange, is it necessary that MTB review the
operator's calculations, i.e., is it necessary
for an operator to apply for a waiver?
d. If it is allowable for operators to exceed the
maximum working pressure rating established by
its manufacture, what specific tests or
calculations contained in the documents
incorporated by reference in Part 195 are
allowable to prove that flanges and valves can
be safely operated in excess of the
manufacturer's rating?
2. For Section 195.406(a)(4):
Does this paragraph allow the operating pressure of
valves to be 80 percent of the factory test
pressure or the prototype test pressure? The ANSI
rating is lower than 80 percent of a prototype
pressure test on a valve.
3. For Section 203(d) of the Hazardous Liquid Pipeline
Safety Act:
Will the "grandfather" provision of the HLPSA
exempt valves installed prior to the adoption of
Part 195 from the requirements of Part 195,
DB
C:\WP51\INTERPRT\195\406\81-06-17
7

<<<PAGE 8>>>

including Section 195.406?
DB
C:\WP51\INTERPRT\195\406\81-06-17
8

<<<PAGE 9>>>

APPENDIX A
Operator Justification
1. Phillips Petroleum Co. (CPFs 3520 & 5506-1)
Operator's justifications are:
a. Section 400(e) of ANSI B31.4-1974 gives them the
authority to act as a designer and, by complete and
rigorous calculations, uprate the pressure ratings
established by the valve manufacturer.
b. By their own calculations based on the formulas in
ANSI B16.5, Section 6.1; ASME Boiler and Pressure
Vessel Code, Section VIII, Appendix 2; and ASME
Boiler and Pressure Code, Section VIII, Division I,
the operator has proven to their own satisfaction
that these valves are safe to operate at pressures
greater than their current operating pressures.
The above standards are all incorporated in Part
195.
c. The valves in the pipeline cited were manufactured
under API 600. These valves have thicker walls
than valves manufactured on API 6D.
d. Operating history proves that these valves are
capable of operating at their current pressures.
Some of these valves have operated at these
pressures for over 30 years.
e. ANSI B16.5, "Steel Pipe Flanges and Flanged
Fittings," is conservative and needs updating.
As a matter of company policy, manufacturer's pressure ratings
are no longer exceeded when new valves are installed or old
valves are replaced.
2. Williams Pipe Line Co. (CPFs 3521 & 3523)
Operator's justifications are:
a. Operator believes that Section 195.406(a)(4) allows
the operating pressure of valves to be 80 percent
of the factory test pressure of valves for any
individually installed component which is excepted
from testing under Section 195.304.
DB
C:\WP51\INTERPRT\195\406\81-06-17
9

<<<PAGE 10>>>

b. Operator believes that safety factors for valves
and flanges, as provided by industry standards such
as API 6D and ANSI B16.5, is out of proportion to
the criteria provided by Section 195.406 for pipe
and components.
c. d. Operator has had a long operating history with no
problems with the valves in question. Two of the
pipelines involved were constructed in the early
1930's.
The pipelines are now being operated at pressures
lower than they were operated prior to the advent
of the pipeline safety regulations of Part 195.
3. Mid-America Pipe Line System (CPF 3522)
Operator's justification are:
a. When operator now orders valves, they request
manufacturer to test valve body to 1.5 times the
working pressure of MAPCO's pipeline. MAPCO also
requested that the valve seats be tested to 1.1
times the pipeline working pressure. MAPCO
believes that based on Section 6 of API 6D (Ratings
for Special Valves), that this testing and their
own hydrostatic field testing would allow the
valves to operate at higher pressures.
b. MAPCO believes that since the valves are operated
below 80 percent of their field test pressures and
60 percent below of the factory design pressure
test, they are in compliance with Sections 195.406
and 195.116(d).
c. Operator feels that they are the designer of the
pipeline and they accept total design
responsibility for the pipeline. Therefore, they
can determine what the safe design pressure of the
pipeline is.
d. Operator does not believe in "cookbook
engineering." They believe both the ANSI B16.5 and
API 6D are conservative and out of date.
e. Operator also believes that their operating history
proves that these valves can be safely operated at
these pressures.
4. National Cooperative Refinery Association (NCRA) (No
DB
C:\WP51\INTERPRT\195\406\81-06-17
10

<<<PAGE 11>>>

b. CPF)
The question of pressure ratings with NCRA is different
from the other companies because this case involves
valves that do not carry ANSI or API ratings, but are
marked as "2000 test - 1000 CWP" or "1000 OWG." Some
manufacturers make valves with this rating. There is no
directly equivalent ANSI or API rating for the 1000 OWG
or CWP rating.
Operator's justifications are:
a. Valves marked as 1000 OWG were tested at time of
manufacture to 2000 psig. Based on most industry
codes, this would establish a working pressure of
1333 psig.
Operator believes that since these valves are in a
products line where there is no internal corrosion,
then can take into consideration the valve's
"corrosion allowance." This is recognized in ASME
Code, Section VIII and is commonly used in all
industry. NCRA claims that valve manufacturers use
a corrosion allowance of about 1/4 inch for a 6-
inch valve with a wall thickness of 7/8 inch. NCRA
by using 1/8 inch for the corrosion allowance would
pressure uprate these valves 16.79 percent (1333
psig to 1555 psig).
c. The valves in question are Wescott Valves.
Walworth Valve Co. purchased the Wescott Valve Co.
and was selling the Wescott pipeline valve under
the Walworth name. NCRA has a Walworth Co. drawing
of this valve which shows the working pressure to
be 1440 WOG at 100 degrees Fahrenheit for a ring
joint faced flange. The Wescott valves have the
same dimensions as the Walworth valves in the
drawing. It is unknown why the valve body is
marked 1000 OWG when the drawing shows 1440 psig.
All of the valves which have been cited as bearing
the 1000 OWG or CWP were manufactured prior to
1945. It is known that in 1950, the ASME, Section
VIII code for unfired pressure vessels changed from
allowable stresses reflecting a factor of safety of
5 over to allowable stresses reflecting a factor of
safety of 4, thus uprating objects with the same
thickness to a higher pressure rating. They
believe that these valves would be qualified for
this consideration.
d. DB
C:\WP51\INTERPRT\195\406\81-06-17
11

<<<PAGE 12>>>

e. Operator has no failure problem with either the
valves or flanges during their operating history.
f. NCRA has offered to test the valves by the
hydrostatic brittle coating test in ASME, Section
VIII, paragraph UG-101 to prove to us that they can
operate at their present pressures.
DB
C:\WP51\INTERPRT\195\406\81-06-17
12
- **truncated:** false
- **body characters:** 17124
