# Pipeline Safety Interpretation PI-82-0103

- **operation:** document
- **citation:** PI-82-0103
- **title:** Pipeline Safety Interpretation PI-82-0103
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1982-05-12
- **effective on:** Not available
- **summary:** PI-82-0103 concerning 192.271.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-82-0103.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-82-0103.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-82-0103
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1982/g82-05-12_haydel_192.271-nlmx.pdf
**body:**

<<<PAGE 1>>>

PI-82-0103
May 12, 1982
Mr. Stanley P. Haydel
AMP Tuboscope, Inc.
P. O. Box 808
Houston, Texas 77001
Dear Mr. Haydel:
Your letter of March 30, 1982, asks us to confirm on the basis of a laboratory test report from Anderson & Associates,
Inc., that a particular means of mechanically joining lengths of steel pipe meets the requirements of 49 CPR 192.271 and
192.273.
The report shows the results of destructive tests run on API 5L Grade B pipe material. In each of the eight specimens
tested, tensile and pressure strength values exceeded the 30,000 p.s.i. minimum yield strength of the material. These
tests plus the hardness values demonstrate the capability of the connection to produce a joint that is stronger than the
design strength of the pipe tested. Thus, the connection appears capable of producing a joint that can withstand
expansion and contraction forces and external and internal loading mentioned in §192.273(a), and that is gastight as
required by §192.273(b). However, actual compliance with §192.273 would depend on proper installation of the con-
nection by a pipeline operator under field conditions, a matter which we can not judge based on the test report alone.
Let me add that our confirmation is not necessary for you to market the connection. Indeed, Part 192 is intentionally
self-effectuating to avoid governmental approvals, and it is our policy not to endorse proprietary methods that meet the
applicable requirements of Part 192.
Sincerely,
SIGNED
Melvin A. Judah
Acting Associate Director for
Pipeline Safety Regulation
Materials Transportation Bureau

<<<PAGE 2>>>

AMF
Tuboscope, Inc.
P.O. Box 808
Houston, Texas 77001
March 30, 1982
Mr. Mel Judah
Associate Director of Pipeline Safety Regulations
Material Transportation B
400 7th Street Southwest
Washington, D.C. 20590
Dear Mr. Judah:
AMF Tuboscope, Inc. is marketing a mechanical interference fit connection for joining pipelines. The major uses of such
a connection are for laying water and CO2 flood lines, gathering systems, disposal systems, and transmission lines.
We have had a number of questions from pipeline companies relative to our compliance with D.O.T. regulations. In
attempting to answer such questions, we have been in contact with the D.O.T. office here in Houston. We were
informed we would probably fall under Title 49, Subpart F - Joining of Materials Other Than by Welding, Section 192.271
- Scope and Section 192.273 - General.
We were also told we would need an interpretation from your office as to our compliance with the above referenced
section. Based on that I am enclosing a copy of the report prepared by an independent testing laboratory on our
mechanical interference fit connection. The report covers the testing procedures on seamless and EPW pipe joined by
the mechanical connection. The results of tensil testing to failure, hydrostatic testing to failure, and hardness testing are
outlined in the report.
As a result of our meeting with the local office, it appears that the connection is in compliance with section 192.271 and
192.273. We are therefore respectfully requesting your confirmation of our findings.
Should you have any questions or desire further data, we will be glad to respond.
Sincerely,
Stanley P. Haydel
Special Sales Representative
Crimp-Kote Services