# Westar Transmission Company — Pipeline Safety Interpretation

- **operation:** document
- **citation:** PI-87-001
- **title:** Westar Transmission Company — Pipeline Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1987-01-20
- **effective on:** Not available
- **summary:** PI-87-001 response to Westar Transmission Company concerning 192.229.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-87-001.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-87-001.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-87-001
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1987/PI87001.pdf
**body:**

<<<PAGE 1>>>

Mr. Nabil S. Dia, P.E.
Westar Transmission Company
P.O. Box 0-
Amarillo, Texas 79189
Dear Mr. Dia:
Your December 22, 1986, letter to this Office asks, if a welder qualified under the requirements of
§192.227(a), in accordance with Section IX of the ASME Boiler & Pressure Vessel Code
(destructive testing), has a production weld tested and accepted under section 6 of API Standard
1104 (nondestructive testing) every 6 months as required by §192.229(c), is that welder subject to
further follow-up destructive testing.
The requirements of §192.229(a) do not apply because the original welder qualification under
§192.227(a) was based on destructive testing. The periodic testing required by §192.229(c) as a
verification of the original qualification under Section IX of ASME is net by the 6-month x-rays.
Therefore, further destructive testing is not required to maintain the original qualification under
§192.227(a).
Sincerely,
/signed/
Richard L. Beam
Acting Director
Office of Pipeline Safety