# Public Utility Commission of Oregon — Pipeline Safety Interpretation

- **operation:** document
- **citation:** PI-90-004
- **title:** Public Utility Commission of Oregon — Pipeline Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1990-02-14
- **effective on:** Not available
- **summary:** PI-90-004 response to Public Utility Commission of Oregon concerning 192.1.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-90-004.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-90-004.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-90-004
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1990/PI90004.pdf
**body:**

<<<PAGE 1>>>

Mr. Mike Kane
Assistant Commissioner
Utility Program
Public Utility Commission of Oregon
Labor & Industries Building
Salem, Oregon, 97310-0335
Dear Mr. Kane:
Thank you for the copy of your September 7, 1989, letter to Kevin Madden of FERC regarding
the safety of customer-owned lines that are supplied high-pressure gas by taps on interstate
transmission lines. The letter indicates we need to explain the application of the Part 192
regulations to these high-pressure customer-owned lines.
Part 192 applies to the transportation of gas by pipeline, which includes each of the recognized
stages of gas pipeline transportation - gathering, transmission, and distribution. As the Part 192
definition of "service line " indicates, the jurisdiction of Part 192 over the distribution of gas ends
at the customer meter or the connection to customer-owned piping, whichever point is farther
downstream. In contrast, the regulations do not specify a point on a pipeline at which jurisdiction
over the gathering or transmission of gas ends. Thus, the full length of pipelines used in the
gathering or transmission of gas comes under the jurisdiction of Part 192, without limitation by
customer meters or the beginning of customer-owned piping.
Under Part 192 the question of whether a pipeline is used on the transmission or distribution of
gas is determined by the definitions of "transmission line" and "distribution line." Note that the
distribution-line definition provides that a pipeline is not a distribution line if it qualities as a
transmission line.
Applying these definitions to taps on interstate transmission lines, we find that the taps are
classified as transmission lines when, in accordance with out longstanding interpretation of the
definition of "transmission line," they are used to deliver a large volume of gas to a customer.
Large volumes include delivery in the 400-800 psig range you mentioned. The high-pressure
customer-owned lines located downstream from meters at these high-pressure taps are merely
lateral extensions of transmission lines.
The jurisdiction of Part 192 over customer-owned gas transmission lines was made evident when
we granted the International Paper Company a waiver from a Part 192 corrosion control rule for
DB
C:\WP51\INTERPRT\192\3\900-02-14
1

<<<PAGE 2>>>

an interstate transmission line the company operates to supply its paper mill in Natchez,
Mississippi. (50 FR 45186, October 30, 1985).
We recognize that because the regulations lack an express jurisdictional end point for the
transmission of gas, confusion may arise regarding the bounds of Federal or State authority over
customer-owned transmission lines. In this regard, a rulemaking proceeding has been scheduled
to propose that our large-volume-customer interpretation be codified in the Part 192 definition of
transmission line. We will include in that proceeding a proposal to adopt a suitable end point for
the jurisdiction of Part 192 over customer-owned transmission lines.
Your letter does not say whether the Oregon Public Utility Commission has jurisdiction over the
customer-owned high pressure lines in question. We prefer that enforcement of Part 192 against
operators of such intrastate lines handled directly by State agencies.
Sincerely,
George W. Tenley, Jr.
Director
Office of Pipeline Safety