# Texaco Trading and Transportation, Inc. — Pipeline Safety Interpretation

- **operation:** document
- **citation:** PI-92-026
- **title:** Texaco Trading and Transportation, Inc. — Pipeline Safety Interpretation
- **source type:** guidance
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** guidance
- **official:** true
- **published on:** 1992-07-09
- **effective on:** Not available
- **summary:** PI-92-026 response to Texaco Trading and Transportation, Inc. concerning 195.1, 195.2.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-92-026.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-92-026.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-interpretation-pi-92-026
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1992/PI92026.pdf
**body:**

<<<PAGE 1>>>

July 9, 1992
Mr. G. G. Hohnstein
Central District Manager
Texaco Trading and Transportation, Inc.
5005 Business Park North Suite 200
Bakersfield, CA 93309
Dear Mr. Hohnstein:
This responds to your letter of June 17, 1992, asking whether the
following pipeline facilities are subject to the safety standards
in 49 CFR Part 195:
(1) An 8-inch steel petroleum pipeline, identified as 8M-
68, that runs between the Fellows Pump Station and the
Olig Pump Station, passing through Derby Acres, a
residential community of 336 people.
(2) The Fellows Pump Station.
Based on Drawing No. 303-R-234 and your description of 8M-68, we
have concluded that 8M-68 is a gathering line as defined in
?195.2. It is 8 inches in nominal diameter and transports
petroleum collected from various production facilities.
Part 195 applies to pipeline facilities used in the
transportation of petroleum. However, because of the exception
in ?195.1(b)(4), Part 195 has only limited application to
gathering lines. It applies only to (1) gathering lines or
portions of gathering lines located outside rural areas, as
defined in ?195.2; and (2) any part of a gathering line or
associated pipeline facility located in a rural area that is
necessary for a non-rural gathering line or portion of gathering
line to comply with Part 195. With regard to 8M-68, Part 195
applies to the segment inside Derby Acres and to any facility
outside Derby Acres that is necessary for the Derby Acres segment
to meet Part 195 (e.g., pressure control devices at commodity
receiving points).
As for the Fellows Station, its pipeline facilities are used in
the gathering of petroleum. As such, the facilities are subject
to the same jurisdictional limits as 8M-68. Since the station is
in rural areas, Part 195 does not apply to any of its facilities
except those that may be necessary for a nonrural gathering line
or portion of gathering line to comply with Part 195. For
dal\195\1\92-07-09
1

<<<PAGE 2>>>

example, if the Fellows pumps were positioned to feed 8M-68, the
associated pressure relief devices at Fellows would be subject to
2
Part 195 if they are necessary to control pressure in the Derby
Acres segment.
I hope you find this information useful. Should you need further
clarification, please call me at (202) 366-1640.
Sincerely,
Cesar De Leon
Director, Regulatory Programs
Office of Pipeline Safety
dal\195\1\92-07-09
2
- **truncated:** false
- **body characters:** 2401