# CONSUMERS ENERGY CO — Integrity Assurance Notification

- **operation:** document
- **citation:** PHMSA 23-292093
- **title:** CONSUMERS ENERGY CO — Integrity Assurance Notification
- **source type:** inspection
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** historical
- **official:** true
- **published on:** 2023-11-06
- **effective on:** 2023-11-06
- **summary:** GAS TRANSMISSION in MI; ECA MECHANICAL DAMAGE EVALUATION; PHMSA status: OBJECTIONS RESOLVED.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-leading-ian-23-292093-operator-2748.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-leading-ian-23-292093-operator-2748.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-leading-ian-23-292093-operator-2748
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/data_statistics/pipeline/SRCR_and_Integrity_Assurance_Notifications.zip
**body:**

This procedure addresses the response to indications of dents or other damage with the potential to contain or develop a stress riser, or other integrity impact. An operator must use a procedure that includes an Engineering Critical Assessment (ECA). This addresses the requirements of CFR 192.712.c. In some cases, an ECA may be an option used to substantiate a longer timeframe for remediation where explicit repair timelines are normally required. In other cases, ECA may be required to classify a dent or damage as a monitored condition (generally applies to any dent over 2% in depth).