# PACIFIC GAS & ELECTRIC CO — Integrity Assurance Notification

- **operation:** document
- **citation:** PHMSA 26-370835
- **title:** PACIFIC GAS & ELECTRIC CO — Integrity Assurance Notification
- **source type:** inspection
- **agency:** Pipeline and Hazardous Materials Safety Administration
- **status:** historical
- **official:** true
- **published on:** 2026-04-24
- **effective on:** 2026-04-24
- **summary:** GAS TRANSMISSION in CA; MAOP RECONFIRMATION METHOD 6; PHMSA status: RESOLVED.
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-leading-ian-26-370835-operator-15007.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-leading-ian-26-370835-operator-15007.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-leading-ian-26-370835-operator-15007
- **source url:** https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/data_statistics/pipeline/SRCR_and_Integrity_Assurance_Notifications.zip
**body:**

Pacific Gas and Electric Company (PG&E) has performed MAOP reconfirmation via § 192.624(c)(6) Alternative Technology of the joints at its 24th and 20th Ave Station to reconfirm Maximum Allowable Operating Pressure (MAOP). This station is in Sacramento, California and provides gas to serve the Rancho Cordova area. initial phase of this project identified all traceable, verifiable, and complete (TVC) records to validate MAOP based on design and pressure test records. At this station pressure test records of four (4) joints are not TVC. These joints are located in a High Consequence Area (HCA). They are located in a Class 3 location.
- **truncated:** false
- **body characters:** 638