{"operation":"document","citation":"PHMSA ok2013hlprogramevaluation","title":"2013 OK HL Program Evaluation - ok2013hlprogramevaluation (Oklahoma; Hazardous Liquid State Program Evaluation)","source_type":"inspection","agency":"Pipeline and Hazardous Materials Safety Administration","status":"historical","official":true,"published_on":"2013-01-01","effective_on":null,"summary":"2013 PHMSA hazardous liquid program evaluation for Oklahoma.","machine_formats":{"json":"https://regulus.evalyn.ai/document/phmsa-state-evaluation-ok-hl-program-evaluation-ok2013hlprogramevaluation.json","markdown":"https://regulus.evalyn.ai/document/phmsa-state-evaluation-ok-hl-program-evaluation-ok2013hlprogramevaluation.md"},"app_url":"https://regulus.evalyn.ai/document/phmsa-state-evaluation-ok-hl-program-evaluation-ok2013hlprogramevaluation","source_url":"https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/subdoc/1381/ok2013hlprogramevaluation.pdf","body":"1200 New Jersey Avenue SE Washington DC 20590 U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration 2013 Hazardous Liquid State Program Evaluation for Oklahoma Corporation Commission Document Legend PART: O -- Representative Date and Title Information A -- Progress Report and Program Documentation Review B -- Program Inspection Procedures C -- Program Performance D -- Compliance Activities E -- Accident Investigations F -- Damage Prevention G -- Field Inspections H -- Interstate Agent State (if applicable) I -- 60106 Agreement State (if applicable) DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 1\n\n2013 Hazardous Liquid State Program Evaluation -- CY 2013 Hazardous Liquid State Agency: Oklahoma Rating: Agency Status: Date of Visit: 04/19/2014 - 08/29/2014 Agency Representative: Dennis Fothergill, Pipeline Safety Manager PHMSA Representative: Patrick Gaume, State Liaison Commission Chairman to whom follow up letter is to be sent: Name/Title: Mr. Bob Anthony, Chairman Agency: Oklahoma Corporation Commission Address: 2101 N. Lincoln Blvd. City/State/Zip: Oklahoma City, Oklahoma 73105 60105(a): Yes 60106(a): No Interstate Agent: No INSTRUCTIONS: Complete this evaluation in accordance with the Procedures for Evaluating State Pipeline Safety Program. The evaluation should generally reflect state program performance during CY 2013 (not the status of performance at the time of the evaluation). All items for which criteria have not been established should be answered based on the PHMSA representative's judgment. A deficiency in any one part of a multiple part question should be scored as needs improvement. Determine the answer to the question then select the appropriate point value. If a state receives less then the maximum points, include a brief explanation in the space provided for general comments/regional observations. If a question is not applicable to a state, select NA. Please ensure all responses are COMPLETE and ACCURATE, and OBJECTIVELY reflect state program performance. Increasing emphasis is being placed on performance. This evaluation together with selected factors reported in the state's annual progress report attachments provide the basis for determining the state's pipeline safety grant allocation. Field Inspection (PART G): The field inspection form used will allow different areas of emphasis to be considered for each question. Question 13 is provided for scoring field observation areas. In completing PART G, the PHMSA representative should include a written summary which thoroughly documents the inspection. Scoring Summary PARTS Possible Points Points Scored A Progress Report and Program Documentation Review 10 10 B Program Inspection Procedures 15 15 C Program Performance 43 43 D Compliance Activities 15 15 E Accident Investigations 9 9 F Damage Prevention 8 8 G Field Inspections 12 12 H Interstate Agent State (if applicable) 0 0 I 60106 Agreement State (if applicable) 0 0 TOTALS 112 112 State Rating................................................................................................................................................... 100.0 DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 2\n\nPART A - Progress Report and Program Documentation Review Points(MAX) Score 1 Accuracy of Jurisdictional Authority and Operator/Inspection Units Data - Progress Report Attachment 1 (A1a) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: A1. Yes, Attachment 1 agrees with Attachment 3 & 8. 1 1 2 Review of Inspection Days for accuracy - Progress Report Attachment 2 (A1b) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: A2. Yes. Attachment 2 is in agreement with OCC State records. 1 1 3 Accuracy verification of Operators and Operators Inspection Units in State - Progress Report Attachment 3 (A1c) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: A3. Yes. Attachment 3 is correct; discrepancies with the operator lists out of PDM were explained. 1 1 4 Were all federally reportable incident reports listed and information correct? - Progress Report Attachment 4 (A1d) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: A4. Yes. 2 Gas Distribution incident, 2 Gas Transmission incidents & 4 HL accident 1 1 5 Accuracy verification of Compliance Activities - Progress Report Attachment 5 (A1e) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: A5. Yes. Attachment 5 is internally consistent and in agreement with State records. 1 1 6 Were pipeline program files well-organized and accessible? - Progress Report Attachment 6 (A1f, A4) Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: A6. Yes, the paper files are in the Pipeline Section Office area and are well organized 2 2 7 Was employee listing and completed training accurate and complete? - Progress Report Attachment 7 (A1g) Yes = 1 No = 0 Needs Improvement = .5 1 1 Evaluator Notes: A7. Yes. This information is auto loaded from the TQ database. Managers and individual inspectors double check their records. They also closely track the courses taken by every inspector. 8 Verification of Part 195,198,199 Rules and Amendments - Progress Report Attachment 8 (A1h) Evaluator Notes: Yes = 1 No = 0 Needs Improvement = .5 A8. Yes. The Oklahoma laws are properly cross referenced to Attachment 8. 1 1 9 List of Planned Performance - Did state describe accomplishments on Progress Report in detail - Progress Report Attachment 10 (H1-3) 1 1 DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 3\n\nYes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: A9. Yes. Staff status-historically authorized for 13 FTE, reduced to 12 FTE in 2008; On 4/23/12-14 FTE authorized & had 14 employees. Authorized to 15 FTE effective 7/1/13. Hired the 15th employee on September 23rd, 2013. In transition toward electronic files, Continuing efforts to implement all 9 elements of Damage prevention. Is dedicating personnel resources toward CRM, PAPEI, IMP, OQ, & D&A inspections in addition to continuing with Standard, Special, & Construction inspections & responding to incidents and accidents. 10 General Comments: Info Only Info Only Info Only = No Points Evaluator Notes: A10. The Pipeline Safety Department was authorized to 15 FTE effective 7/1/13, and hired the 15th employee on September 23rd, 2013. The transition toward electronic files is continuing. Continuing efforts to implement all 9 elements of Damage prevention were made, as House Bill 2533, to extend authority over excavators, was signed into Law and became effective July 1st, 2014. The Rule Making to implement the new Law is being developed. The Department is dedicating personnel resources toward CRM, PAPEI, IMP, OQ, & D&A inspections in addition to continuing with Standard, Special, & Construction inspections & responding to incidents and accidents. Total points scored for this section: 10 Total possible points for this section: 10 DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 4\n\nPART B - Program Inspection Procedures Points(MAX) Score 1 Standard Inspections (B1a) Yes = 2 No = 0 Needs Improvement = 1 2 2 Evaluator Notes: B1 Yes, have procedures in SOP pages 1-11. The SOP shows that Units are inspected every 2-3 years, but certain Systems in large Units may be on a 4-5 year rotation. Std insp 1-5 years per risk ranking. 2 IMP Inspections (B1b) 1 1 Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: B2. Yes. IMP plan review is on an 8 yr cycle. It is presently risk ranked based on HCA miles in Oklahoma. Changes in HCAs are addressed during Std Inspections using their Oklahoma Addendum. This round of scheduling is being driven by inspection frequencies. 3 OQ Inspections (B1c) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: 1 1 B3 Yes. OQ plan review is on a 10 yr cycle and Protocol 9 inspections are included in most Standard Inspections. 4 Damage Prevention Inspections (B1d) 1 1 Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: B4. Yes, Damage Prevention is part of the Std Insp; see SOP pgs 2 & 3 of 11. 5 On-Site Operator Training (B1e) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: B5. Yes, see SOP pg 7 of 11. 1 1 6 Construction Inspections (B1f) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: B6 Yes. These inspections will be conducted as needed and as per the SOP pg 4 of 11. 1 1 7 Incident/Accident Investigations (B1g) 2 2 Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: B7 Yes. These inspections will be conducted as needed and as per the SOP pg 6 of 11. 8 Does inspection plan address inspection priorities of each operator, and if necessary each 6 6 unit, based on the following elements? (B2a-d, G1,2,4) Yes = 6 No = 0 Needs Improvement = 1-5 a. Length of time since last inspection Yes No Needs Improvement b. Operating history of operator/unit and/or location (includes leakage, incident and compliance activities) Yes No Needs Improvement c. Type of activity being undertaken by operators (i.e. construction) Yes No Needs Improvement d. Locations of operators inspection units being inspected - (HCA's, Geographic area, Population Density, etc) Yes No Needs Improvement DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 5\n\ne. Process to identify high-risk inspection units that includes all threats - (Excavation Damage, Corrosion, Natural Forces, Outside Forces, Material and Welds, Equipment, Yes No Needs Improvement Operators and any Other Factors) f. Are inspection units broken down appropriately? Yes No Needs Improvement Evaluator Notes: B8 YES, the various risk factors have been identified and written into the SOP pages 6-7 of 11. The database has been developed, is being used, and is being reviewed and refined for its value. Right now the value of the database is minimal to moderate. Discussion with other state program managers is on-going. 9 General Comments: Info Only Info Only Info Only = No Points Evaluator Notes: B9. The OCC was successful in completing the PAPEI Inspections before 12/31/2013. The OCC has increased staff to 15 FTE to address IMP, OQ, CRM, PAPEI, etc, while continuing with Standard, Construction, and Incident/Accident inspections. John Harper and his staff are tasked to schedule and coordinate these newer inspections and to be a source of management support. It is everyone's goal to shrink re-inspection intervals to 7 years or less for every type of inspection. Total points scored for this section: 15 Total possible points for this section: 15 DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 6\n\nPART C - Program Performance Points(MAX) Score 1 Was ratio of Total Inspection person-days to total person days acceptable? Yes = 5 No = 0 A. Total Inspection Person Days (Attachment 2): 267.00 B. Total Inspection Person Days Charged to the Program (220 X Inspection Person Years) (Attachment 7): 220 X 2.10 = 462.00 Ratio: A / B 267.00 / 462.00 = 0.58 If Ratio >= 0.38 Then Points = 5, If Ratio < 0.38 Then Points = 0 Points = 5 Evaluator Notes: C1 Yes. A=267 person days. B=2.1 man years * 220 = 462 person days. A/B= .578 . .578>.38, okay. 5 5 2 Has each inspector and program fulfilled the T Q Training Requirements? (See 5 5 Guidelines for requirements) Chapter 4.4 (A8-A11, G19) Yes = 5 No = 0 Needs Improvement = 1-4 a. Completion of Required OQ Training before conducting inspection as lead? Yes No Needs Improvement b. Completion of Required IMP Training before conducting inspection as lead Yes No Needs Improvement c. Root Cause Training by at least one inspector/prgram manager Yes No Needs Improvement d. Note any outside training completed Yes No Needs Improvement Evaluator Notes: C2 Yes, all inspectors & managers with 3+ years of service have passed all TQ core courses, and the new inspectors are taking courses and are scheduled for the rest. All Leads have the necessary courses. 3 Did state records and discussions with state pipeline safety program manager indicate adequate knowledge of PHMSA program and regulations? Chapter 4.1,8.1 (A5) Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: C3 Yes, The Program Managers show a professional knowledge of the regulations. 2 2 4 Did state respond to Chairman's letter on previous evaluation within 60 days and correct or address any noted deficiencies? (If necessary) Chapter 8.1 (A6-7) Yes = 2 No = 0 Needs Improvement = 1 2 2 Evaluator Notes: C4 Yes, The OCC Chairman responded in 60 days of receipt (8/7/13 & 10/7/13). Both items were addressed. 5 Did State hold PHMSA TQ Seminar in Past 3 Years? Chapter 8.5 (A3) 2 2 Yes = 2 No = 0 Evaluator Notes: C5 Yes. OCC uses an 18 month TQ schedule. The last Seminar was in May, 2013; the next one is scheduled for November, 2014; both in Tulsa. 6 Did state inspect all types of operators and inspection units in accordance with time intervals established in written procedures? Chapter 5.1 (B3) Yes = 5 No = 0 Needs Improvement = 1-4 5 5 Evaluator Notes: C6 Yes, Units are being inspected in accordance with the SOP. Inspections are tracked to the System level & the year and type of inspection are recorded by System. CRM started in 2012. PAPEI started in 2011 & the first round of inspections were completed by 12/31/13. Re-inspection frequency has been set to a maximum of 5 years. DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 7\n\n7 Did inspection form(s) cover all applicable code requirements addressed on Federal 2 2 Inspection form(s)? Did State complete all applicable portions of inspection forms? Chapter 5.1 (B4-5) Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: C7. Yes. OCC uses the current federal form supplemented with an addendum sheet. Reviewed 13 inspections with most noting probable violations. The inspections were complete and internally consistent and OCC procedures were followed concerning the PV and followup. Inspections reviewed were: NG-13-501 PAPEI JH, NG-13-456 Municipal Standard JR, HL-13-067 Standard Ron&VE, NG-13-104 Municipal Standard RM, NG-13-740 Municipal Standard RK&DM, NG-13-338 Standard Distr MB&BL, NG-13-143 Transmission Standard MS, NG-13-526 Transmission Incident BC, NG-13-566 Transmission Standard RK&BC, NG-13-361 DIMP JH, NG-13-161 PAPEI JH, HL-13-022 Standard VE&RonS, HL-13-020 Accident VE. 8 Did the state review operator procedures for determining areas of active corrosion on liquid lines in sufficient detail? (NOTE: PHMSA representative to describe state criteria for determining areas of active corrosion) (B7) Yes = 1 No = 0 Evaluator Notes: C8. Yes, it is part of the standard inspection and is reviewed on a Unit by Unit level. 1 1 9 Did the state adequately review for compliance operator procedures for abandoning pipeline facilities and analyzing pipeline accidents to determine their causes? (NOTE: PHMSA representative to describe state criteria for determining compliance with abandoning pipeline facilities and analyzing pipeline accidents to determine their causes) (B8) Yes = 1 No = 0 Evaluator Notes: C9. Yes, accident and abandonment procedures are reviewed during Standard Inspections. 1 1 10 Is the state aware of environmentally sensitive areas traversed by or adjacent to hazardous liquid pipelines? (reference Part 195, review of NPMS) (B9) Yes = 1 No = 0 Evaluator Notes: C10. Yes, Inspectors are familiar with HCAs and USAs. 1 1 11 Did the state review operator records of previous accidents and failures including reported third party damage and leak response to ensure appropriate operator response as required by 195.402(c)(5)? (B10,E5) Yes = 1 No = 0 Evaluator Notes: C11. Yes, this is part of standard inspections and accident investigations. 1 1 12 Has the state reviewed Operator Annual reports, along with Incident/Accident reports, for 2 2 accuracy and analyzed data for trends and operator issues? Data Initiative (G5-8,G15) Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: C12. Yes, OCC reviews the Form for completeness, miles of pipe, and for data accuracy into various columns. Finally the spreadsheet has several years of annual report data. 13 Did state input all applicable OQ, IMP inspection results into federal database in a timely 2 2 manner? This includes replies to Operator notifications into IMDB database. Chapter 5.1 (G9-12) Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: C13. Yes, all of the IMP & OQ inspections for 2013 have been uploaded, typically within 60 days of the inspection. ThereDUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 8\n\nwere no Operator notifications in 2013 that needed to be uploaded. The focus in 2013 was to continue to conduct Protocol 9 inspections in every Unit that had a standard inspection. Also started IMP & OQ Plan Reviews. 14 Has state confirmed intrastate operators have submitted information into NPMS database along with changes made after original submission? (G13) Yes = 1 No = 0 Needs Improvement = .5 1 1 Evaluator Notes: C14 Yes. It is a multiple year practice and it is now on the new Standard Inspection Form. In addition OCC receives a NPMS report annually and OCC verifies that ALL operators have submitted their annual updates. 15 Is the state verifying operators are conducting drug and alcohol tests as required by regulations? This should include verifying positive tests are responded to in accordance with program. 49 CFR 199 (I1-3) Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: C15 Yes. OCC uses Form 13 for each Standard Inspection Unit and Form 3.1.11 for HQ Plan Reviews. 2 2 16 Is state verifying operators OQ programs are up to date? This should include verification 2 2 of any plan updates and that persons performing covered tasks (including contractors) are properly qualified and requalified at intervals determined in the operators plan. 49 CFR 195 Part G (I4-7) Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: C16 Yes, the federal Form is used, and the re-inspections are within the SOP inspection interval. It is also the practice to perform a Protocol 9 inspecting during every Unit inspection. 17 Is state verifying operator's hazardous liquid integrity management (L IMP) Programs are 2 2 up to date? This should include a previous review of LIMP plan, along with monitoring progress on operator tests and remedial actions. In addition, the review should take in to account program review and updates of operators plan(s). 49 CFR 195.452 Appendix C (C8-12) Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: C17 Yes, OCC has reviewed every operator for HCA/USAs. Every HL Operator with an identified HCA/USA has received a full LIMP Inspection. The inspections have been uploaded into the fed database. This question has been added to the Form 3 addendum sheet since November, 2010. 18 Is state verifying operators Public Awareness programs are up to date and being followed. State should also verify operators have evaluated Public Awareness programs for effectiveness as described in RP1162. 49 CFR 195.440 (I13-16) PAPEI Effectiveness Inspections should be complete by December 2013 2 2 Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: C18 Yes. All PAP were reviewed and resolved with the Operator all the Clearing House and CATS exceptions. PAPEI inspections were started in 2011. Present target for first round of PAPEI Inspections were completed by 12/31/2013. 19 Does the state have a mechanism for communicating with stakeholders - other than state 1 1 pipeline safety seminar? (This should include making enforcement cases available to public). (G19-20) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: C19 Yes, is providing a Pipeline Safety Seminar every eighteen months instead of every 3rd year, Every inspector is providing 5 individual operator training sessions per year (9 inspectors * 5 sessions/inspector = 45 sessions per year), There are also 5 to 10 small operator training seminars given around the State each year. They participate in the Okie One Call (OPAL) public awareness program, also participate with several Operators in their programs, They are continuing to work on DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 9\n\nthe 9 elements from the 2006 PIPES ACT. All Operators have docket access and OCC is moving to establish a Pipeline Safety website where all finalized inspection reports, along with findings of violations, will be available to the public. Currently the Public has rights to request and receive paper and electronic records. 20 Did state execute appropriate follow-up actions to Safety Related Condition (SRC) Reports? Chapter 6.3 (B6) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: 1 1 C20 Yes, Had 0 gas & 3 HL. SRCR are tracked similar to any other inspection, & updates are sent to the Feds. 21 Did the state participate in/respond to surveys or information requests from NAPSR or 1 1 PHMSA? (H4) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: C21. Yes, OCC works with NAPSR, TQ, NTSB, PHMSA, and is on various committees. Dennis Fothergill is on the NAPSR Committee that asks these questions. 22 If the State has issued any waivers/special permits for any operator, has the state verified Info Only Info Only conditions of those waivers/special permits are being met? This should include having the operator amend procedures where appropriate. Info Only = No Points Evaluator Notes: C22. 4 waivers from OK are in the database, see: http://phmsa.dot.gov/portal/site/PHMSA/menuitem. ebdc7a8a7e39f2e55cf2031050248a0c/? vgnextoid=b79f176a31416210VgnVCM1000001ecb7898RCRD&vgnextchannel=7f8da535eac17110VgnVCM1000009ed07 898RCRD&vgnextfmt=print . There have been no other waivers. The 'Clock Spring' waiver is no longer required. 23 General Comments: Info Only Info Only Info Only = No Points Evaluator Notes: C23 The rapid pace of the evolution and change of the Regulations is continuing, but the OCC is committed to meet those changes. Regulation demands and available manpower are regularly reviewed and applied for the most effective results and changes are reflected in the SOP. Staff was increased to 15 FTE in 2013, an all-time high. Total points scored for this section: 43 Total possible points for this section: 43 DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 10\n\nPART D - Compliance Activities Points(MAX) Score 1 Does the state have written procedures to identify steps to be taken from the discovery to 4 4 resolution of a probable violation? Chapter 5.1 (B12-14, B16, B1h) Yes = 4 No = 0 Needs Improvement = 1-3 a. Procedures to notify an operator (company officer) when a noncompliance is identified Yes No Needs Improvement b. Procedures to routinely review progress of compliance actions to prevent delays or breakdowns Yes No Needs Improvement Evaluator Notes: D1. Yes, in the Department Guidelines (SOP) pgs 7-9 of 11, & the Commission Rules & Practice, Chapter 13, Part 3 Procedure. 2 Did the state follow compliance procedures (from discovery to resolution) and adequately 4 4 document all probable violations, including what resolution or further course of action is needed to gain compliance? Chapter 5.1 (B11,B18,B19) Yes = 4 No = 0 Needs Improvement = 1-3 a. Were compliance actions sent to company officer or manager/board director if municipal/government system? Yes No Needs Improvement b. Were probable violations documented? Yes No Needs Improvement c. Were probable violations resolved? Yes No Needs Improvement d. Was the progress of probable violations routinely reviewed? Yes No Needs Improvement Evaluator Notes: D2. Yes, it was done & the mechanism is in the SOP , pg 8 of 11. 3 Did the state issue compliance actions for all probable violations discovered? (B15) Yes = 2 No = 0 Needs Improvement = 1 2 2 Evaluator Notes: D3. Yes, there were 1 Haz Liquid compliance actions in 2013, 3 in 2012, 5 in 2011, 2 in 2010, & 2 in 2009. all were issued within 60 days of the inspection completion. 4 Did compliance actions give reasonable due process to all parties? Including \"show 2 2 cause\" hearing if necessary. (B17, B20) Yes = 2 No = 0 Evaluator Notes: D4 Yes, the mechanism is in the SOP, sec 165:20-13-15. Due process procedures are followed for all parties. In 2013 Two contempt cases were processed. 5 Is the program manager familiar with state process for imposing civil penalties? Were 2 2 civil penalties considered for repeat violations (with severity consideration) or violations resulting in incidents/accidents? (describe any actions taken) (B27) Yes = 2 No = 0 Evaluator Notes: D5. Yes, Dennis knows the process for civil penalties, and the areas where he doesn't have civil penalty authority. Consideration is given for increased civil penalties due to repeat violations and for egregious violations that damage third parties and threaten human life. 6 Can the State demonstrate it is using their enforcement fining authority for pipeline safety 1 1 violations? Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: D6. Yes. OCC has a history of issuing occasional fines. 7 General Comments: DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Info Only Info Only Oklahoma Oklahoma Corporation Commission, Page: 11\n\nInfo Only = No Points Evaluator Notes: D7 OCC is well able to enforce the regulations. OCC recognizes that increased use of civil penalties will likely be needed. Total points scored for this section: 15 Total possible points for this section: 15 DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 12\n\nPART E - Accident Investigations Points(MAX) Score 1 Does state have adequate mechanism to receive and respond to operator reports of 2 2 accidents, including after-hours reports? And did state keep adequate records of Incident/ Accident notifications received? Chapter 6 (A2,D1-3) Yes = 2 No = 0 Needs Improvement = 1 a. Acknowledgement of MOU between NTSB and PHMSA (Appendix D) Yes No Needs Improvement b. Acknowledgement of Federal/State Cooperation in case of incident/accident (Appendix E) Yes No Needs Improvement Evaluator Notes: E1. Yes, Appendix E specifies 1. Determine if safety violations occurred. 2. Determine root causes of the accident if asked by NTSB. 3. Cooperate with NTSB. Yes, the MOU between NTSB and OPS is understood, and OCC fully cooperates with NTSB. Yes, HL accidents are investigated and placed in the files. In addition, the accidents meeting State reporting criteria are in the files. 2 If onsite investigation was not made, did state obtain sufficient information from the 1 1 operator and/or by other means to determine the facts to support the decision to not go on-site? Chapter 6 (D4) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: E2. Yes, In 2013, the Federally reportable incidents & accidents were investigated on-site. In addition most state reportable incidents/accidents were investigated on-site. However the SOP provides for telephonic reporting and after-the-fact follow up. 3 Were all accidents investigated, thoroughly documented, and with conclusions and 3 3 recommendations? (D5) Yes = 3 No = 0 Needs Improvement = 1-2 a. Observations and document review Yes No Needs Improvement b. Contributing Factors Yes No Needs Improvement c. Recommendations to prevent recurrences where appropriate Yes No Needs Improvement Evaluator Notes: E3. Yes, yes, yes, OCC uses the federal Form 11 for incident investigations. The events are documented and Appendix E is followed. 4 Did the state initiate compliance action for violations found during any incident/accident investigation? (D6) Yes = 1 No = 0 Evaluator Notes: E4. Yes, the SOP dictates action similar to any other violation. 1 1 5 Did the state assist region office by taking appropriate follow-up actions related to the 1 1 operator accident reports to ensure accuracy and final report has been received by PHMSA? (validate report data from operators concerning incidents/accidents and investigate discrepancies) Chapter 6 (D7) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: E5. yes, OCC is a full partner with PHMSA and has assisted PHMSA in the past on interstate incidents/accidents to ensure that incident reports are accurate & updated, and the reports are reviewed for completeness & to ensure that a final report is submitted. 6 Does state share lessons learned from incidents/accidents? (sharing information, such as: at NAPSR Region meetings, state seminars, etc) (G15) Yes = 1 No = 0 Evaluator Notes: DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation 1 1 Oklahoma Oklahoma Corporation Commission, Page: 13\n\nE6. Yes, OCC makes a report during the SW Region NAPSR Meeting, and responds as appropriate to email correspondence. In addition, lessons learned are shared at Safety Seminars, trade association meetings, and other training events. 7 General Comments: Info Only Info Only Info Only = No Points Evaluator Notes: E7. In 2013 There were 4 significant incidents & 4 significant accidents. Of those 8 events, 3 were due to excavation damage & 4 due to corrosion (2 internal & 2 external). The last incident was due to a F5 tornado. Efforts continue to keep incidents and accidents minimized. Total points scored for this section: 9 Total possible points for this section: 9 DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 14\n\nPART F - Damage Prevention Points(MAX) Score 1 Has the state reviewed directional drilling/boring procedures of each pipeline operator or 2 2 its contractor to determine if they include actions to protect their facilities from the dangers posed by drilling and other trench less technologies? (E1) Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: F1. Yes, it is addressed in standard inspections during review of line locate and one-call procedures. OCC has created an addendum sheet to address this question, (195.402(a)). 2 Did the state inspector check to assure the pipeline operator is following its written procedures pertaining to notification of excavation, marking, positive response and the availability and use of the one call system? (E2) Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: F2. Yes, it is part of the Standard Inspection Forms for Form 1, Form 2, & Form 3. 2 2 3 Did the state encourage and promote practices for reducing damages to all underground 2 2 facilities to its regulated companies? (i.e. such as promoting/adopting the CGA Best Practices encouraging adoption of the 9 Elements, etc.) (E3) Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: F3. Yes, OCC gives a One-Call & RP 1162 Seminar every 18 months and it includes T&Q Seminars. They also give a One- Call & RP 1162 Seminar in the annual Small Operator/Municipal presentations. 4 Has the agency or another organization within the state collected data and evaluated 2 2 trends on the number of pipeline damages per 1,000 locate requests? (This can include DIRT and other data shared and reviewed by the pipeline safety program) (E4,G5) Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: F4. Yes. OCC has required and received line locates, line hits, and line leaks from the One Call Center and all regulated operators. OCC is using spreadsheet analysis to learn that master meters have almost no risk of line hits. The study of line hits per thousand locates is interesting because the rate varies widely across the various classes of operators. The data includes regulated and non-regulated underground resources. 5 General Comments: Info Only Info Only Info Only = No Points Evaluator Notes: F5. OCC has been able to create a credible database and study by requiring the line locate, hit, and leak data. OCC continues to work toward achieving all 9 elements of Damage Prevention including effective civil penalties of excavators who violate the Damage Prevention regulations. Total points scored for this section: 8 Total possible points for this section: 8 DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 15\n\nPART G - Field Inspections Points(MAX) Score 1 Operator, Inspector, Location, Date and PHMSA Representative Info Only Info Only Info Only = No Points Name of Operator Inspected: Oneok NGL Pipeline Name of State Inspector(s) Observed: Vince Eitzen & Ron Smith, inspector OCC Location of Inspection: Near Coalgate, Techumseh, & Wetumka, OK Date of Inspection: 4/9-11/14 Name of PHMSA Representative: Patrick Gaume Evaluator Notes: G1. Oneok NGL Pipeline, Oneok facilities at the Coalgate Gas Plant, near Coalgate, OK, opid 32109 DOT Contact: Neal Jones 580-395-2377 office 580-761-3547 cell Vince Eitzen & Ron Smith, inspector OCC Near Coalgate, Techumseh, & Wetumka, OK 4/9-11/14 Patrick Gaume Standard HL Inspection 2 Was the operator or operator's representative notified and/or given the opportunity to be present during inspection? (F2) Yes = 1 No = 0 Evaluator Notes: G2. Yes; the operator was notified and a minimum of 713 OneOk Personnel participated in the inspection. 1 1 3 Did the inspector use an appropriate inspection form/checklist and was the form/checklist used as a guide for the inspection? (New regulations shall be incorporated) (F3) Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: G3. Yes. Form 3 HL Standard Inspection, rev7.15.11. plus OCC addendum 2 2 4 Did the inspector thoroughly document results of the inspection? (F4) 2 2 Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: G4. Yes, the inspection was fully documented. 5 Did the inspector check to see if the operator had necessary equipment during inspection to conduct tasks viewed? (Maps,valve keys, half cells, etc) (F5) Yes = 1 No = 0 Evaluator Notes: G5. Yes, multimeter, half cell, hand tools, keys, cell phones, PPE, line locator, special bolt socket. 1 1 6 Did the inspector adequately review the following during the field portion of the state evaluation? (check all that apply on list) (F7) Yes = 2 No = 0 Needs Improvement = 1 a. Procedures b. Records c. Field Activities d. Other (please comment) Evaluator Notes: G6. Yes, I witnessed Records, Field, & OQ Field Evaluations for main-line valves and for Line Locating. DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation 2 2 Oklahoma Oklahoma Corporation Commission, Page: 16\n\n7 Did the inspector have adequate knowledge of the pipeline safety program and 2 2 regulations? (Evaluator will document reasons if unacceptable) (F8) Yes = 2 No = 0 Needs Improvement = 1 Evaluator Notes: G7. Yes, Vince is fully qualified and knowledgeable, and Ron has completed all core classes and did a fine job; he has now completed his second year as a HL inspector. 8 Did the inspector conduct an exit interview? (If inspection is not totally complete the 1 1 interview should be based on areas covered during time of field evaluation) (F9) Yes = 1 No = 0 Evaluator Notes: G8. Yes, two items of concern found: some short bolts were found and a new metering skid had been placed into service without some of the flange bolts being properly torqued. 9 During the exit interview, did the inspector identify probable violations found during the 1 1 inspections? (if applicable) (F10) Yes = 1 No = 0 Evaluator Notes: G9. Yes, two items of concern found: some short bolts were found and a new metering skid had been placed into service without some of the flange bolts being properly torqued. 10 General Comments: What did the inspector observe in the field? (Narrative description of field observations and how inspector performed) Best Practices to Share with Other States - (Field - could be from operator visited or state inspector practices) Other Info Only = No Points a. Abandonment b. Abnormal Operations c. Break-Out Tanks d. Compressor or Pump Stations e. Change in Class Location f. Casings g. Cathodic Protection h. Cast-iron Replacement i. Damage Prevention j. Deactivation k. Emergency Procedures l. Inspection of Right-of-Way m. Line Markers n. Liaison with Public Officials o. Leak Surveys p. MOP q. MAOP r. Moving Pipe s. New Construction t. Navigable Waterway Crossings u. Odorization v. Overpressure Safety Devices w. Plastic Pipe Installation x. Public Education y. Purging z. Prevention of Accidental Ignition A. Repairs B. Signs DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Info Only Info Only Oklahoma Oklahoma Corporation Commission, Page: 17\n\nC. Tapping D. Valve Maintenance E. Vault Maintenance F. Welding G. OQ - Operator Qualification H. Compliance Follow-up I. Atmospheric Corrosion J. Other Evaluator Notes: G10. Items observed included, signs, markers, fencing, locks, atmospheric corrosion, nuts & bolts, AC impressed current mitigation, security signs, ESD, communication and redundant communication, ROW, fire eyes, fire extinguishers, air-soil interface, pipe supports, flange, valve & other component design, valve operation, cp & rectifier inspections, Safety pressure set points, site specific records and schematics, SCADA review, pressure check with the SCADA Center, verify emergency contact number, weeds, site cleanliness, AOC identification, Line locating. Total points scored for this section: 12 Total possible points for this section: 12 DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 18\n\nPART H - Interstate Agent State (if applicable) Points(MAX) Score 1 Did the state use the current federal inspection form(s)? (C1) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: H1-8 NA. not an Interstate Agent. 1 NA 2 Are results documented demonstrating inspection units were reviewed in accordance with \"PHMSA directed inspection plan\"? (C2) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: H1-8 NA. not an Interstate Agent. 1 NA 3 Did the state submit documentation of the inspections within 60 days as stated in its latest Interstate Agent Agreement form? (C3) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: H1-8 NA. not an Interstate Agent. 1 NA 4 Were probable violations identified by state referred to PHMSA for compliance? (NOTE: PHMSA representative has discretion to delete question or adjust points, as appropriate, based on number of probable violations; any change requires written explanation.) (C4) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: H1-8 NA. not an Interstate Agent. 1 NA 5 Did the state immediately report to PHMSA conditions which may pose an imminent safety hazard to the public or to the environment? (C5) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: H1-8 NA. not an Interstate Agent. 1 NA 6 Did the state give written notice to PHMSA within 60 days of all probable violations found? (C6) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: H1-8 NA. not an Interstate Agent. 1 NA 7 Did the state initially submit documentation to support compliance action by PHMSA on probable violations? (C7) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: H1-8 NA. not an Interstate Agent. 1 NA 8 General Comments: Info Only = No Points Evaluator Notes: H1-8 NA. not an Interstate Agent. Info Only Info Only Total points scored for this section: 0 Total possible points for this section: 0 DUNS: 150235299 2013 Hazardous Liquid State Program Evaluation Oklahoma Oklahoma Corporation Commission, Page: 19\n\nPART I - 60106 Agreement State (if applicable) Points(MAX) Score 1 Did the state use the current federal inspection form(s)? (B21) Yes = 1 No = 0 Needs Improvement = .5 Evaluator Notes: I1-7 NA. not a 60106 Agreement State. 1 NA 2 Are results documented demonstrating inspection units were reviewed in accordance ","truncated":true,"body_characters":41468}