# Public Utilities Commission — State Waiver

- **operation:** document
- **citation:** PHMSA-2018-0067
- **title:** Public Utilities Commission — State Waiver
- **source type:** permit
- **agency:** Public Utilities Commission
- **status:** historical
- **official:** true
- **published on:** 2018-07-18
- **effective on:** 2018-07-18
- **summary:** Ohio state waiver granted 2018-07-18 for 49.CFR 192.53(c), 192.121, 192.123, 192.283, 192.283(b), 192.619(a).
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/phmsa-state-waiver-public-utilities-commission-7192018.json
- **markdown:** https://regulus.evalyn.ai/document/phmsa-state-waiver-public-utilities-commission-7192018.md
- **app url:** https://regulus.evalyn.ai/document/phmsa-state-waiver-public-utilities-commission-7192018
- **source url:** https://www.phmsa.dot.gov/pipeline/special-permits-state-waivers/public-utilities-commission-7192018
**body:**

PHMSA-2018-0067. State: Ohio. Entity: Public Utilities Commission. Regulation: 49.CFR 192.53(c), 192.121, 192.123, 192.283, 192.283(b), 192.619(a). Date granted: 2018-07-18.

<<<PAGE 1>>>

Gas Pipeline Satety Program Manager
Public Utilities Commission of Ohio
180 East Broad Street
Columbus, Ohio 43215-3793
PHMSA-2018-0067
Dear Mr. Chace:
The Pipeline and Hazardous Materials Safety Administration (PHMSA) has reviewed your letter
dated May 31, 2018, notifying us that NGO Transmission of the Energy Cooperative (NGOT)
petitioned the Ohio Public Utilities Commission (Commission) for a State Waiver to waive
compliance from the Pipeline Safety Regulations of 49 U.S.C 60118(d) and specifically, 49 CFR
metallic, reinforced thermoplastic pipe manufactured by Specialty RTP, LLC (Specialty RTP
192.53(c), 192.121, 192.123, 192.283(b), and 192.619(a), for NGO1 to install and use a non-
NGOT proposes to use the four-inch reinforced thermoplastic pipe (RTP) to replace
approximately 28,500 feet of six-inch bare steel natural gas transmission pipeline installed in
1955. The State Waiver segment covers the portion of the pipeline from NGOT's tap into
Kinder Morgan's Tennessee Gas Pipeline (known as Spratt Station) in Rich Hill Township,
Muskingum County, Ohio to NGOT's new McDonald Road Station in Salt Creek Township,
Muskingum County, Ohio. The entire line is currently within a Class 1 location. The State
Waiver segment is being designed and tested for a Maximum Allowable Operating Pressure
(MAOP) of 1,000 psi. Typical operating pressure of the line currently is approximately 600 psi
and varies anywhere from 500 psi to 790 psi coming out of the tap at Spratt Station.
NGOT asserts that its use of the RTP would improve the integrity of its system by eliminating
corrosion, reducing environmental impact and cost of alternative construction methodologies,
lowering maintenance costs and increasing resistance to third-party damage. The RTP is
designed, manufactured and tested in accordance with American Petroleum Institute (API)
Recommended Practice 15S "Qualification of Spoolable Reinforced Plastic Line Pipe" and
meets the standards of ISO 9001 for quality management systems. The Commission is imposing
several conditions in the areas of construction personnel qualification, installation, hydrotesting,
corrosion control, and integrity management. Additional information on the application is
available publicly via the Commission's Case Record 17-1751-GA-WVR.

<<<PAGE 2>>>

approval of the Commission's NGO Waiver and the conditions imposed to maintain public and
gas pipeline safety. PHMSA requests that the Commission forward a copy of the issued Waiver
to PHMSA within 30 days of the final approval.
My staff would be pleased to discuss this decision or any other pipeline safety matter with you.
John Gale, Director, Standards and Rulemaking Division, may be contacted at 202-366-4959 on
regulatory matters, and Kenneth Lee, Director, Engineering and Research Division, may be
contacted at 202-366-2694 on technical matters specific to this decision.
Sincerely,
Alan K. Mayberry
Associate Administrator for Pipeline Safety