{"operation":"document","citation":"WAC 480-75-410","title":"Coatings.","source_type":"regulation","agency":"Washington Utilities and Transportation Commission","status":"current","official":true,"published_on":null,"effective_on":"2008-06-30","summary":"Before backfilling, each pipeline company must electrically inspect all new coated pipe used to transport hazardous liquids, using a holiday detector to check for faults not observable by visual examination. The pipeline company shall operate the holiday detector in accordance with the manufacturer'","machine_formats":{"json":"https://regulus.evalyn.ai/document/wac-480-75-410.json","markdown":"https://regulus.evalyn.ai/document/wac-480-75-410.md"},"app_url":"https://regulus.evalyn.ai/document/wac-480-75-410","source_url":"https://app.leg.wa.gov/WAC/default.aspx?cite=480-75-410","body":"Before backfilling, each pipeline company must electrically inspect all new coated pipe used to transport hazardous liquids, using a holiday detector to check for faults not observable by visual examination. The pipeline company shall operate the holiday detector in accordance with the manufacturer's instructions and at the voltage level appropriate for the electrical characteristics of the pipeline being tested.","truncated":false,"body_characters":416}